Development of a Peptide Aptamer-Based TRFIA for the Quantitive Detection of SARS-CoV-2 Nucleocapsid Protein.

IF 2.6 4区 化学 Q2 BIOCHEMICAL RESEARCH METHODS
Hongfang Chen, Tonggong Liu, Xiaona Zhao, Xi Chen, Liwen Zhu, Tingting Jiang, Huawen Li, Dayong Gu
{"title":"Development of a Peptide Aptamer-Based TRFIA for the Quantitive Detection of SARS-CoV-2 Nucleocapsid Protein.","authors":"Hongfang Chen, Tonggong Liu, Xiaona Zhao, Xi Chen, Liwen Zhu, Tingting Jiang, Huawen Li, Dayong Gu","doi":"10.1007/s10895-025-04199-w","DOIUrl":null,"url":null,"abstract":"<p><p>This study, we employed computer-aided design to develop 27 peptide aptamers, and initially screened 11 candidates with binding energies less than - 6.0 kcal/mol. Subsequently, three peptide aptamers with strong specificity were selected using a direct time-resolved fluorescence immunoassay (TRFIA). Peptide aptamer B3, in combination with monoclonal antibody R001, was used to construct a TRFIA-based sandwich assay system. The performance of this system was evaluated concerning sensitivity, specificity, and reproducibility, and was further tested using 20 simulated pharyngeal swab samples. The dominant peptide aptamer, B3(RGQGVPI), was identified as the most promising candidate. This peptide demonstrated high specificity for the SARS-CoV-2 nucleocapsid (N) protein, with the lowest detectable concentration of 203.78 pg/mL. Importantly, the peptide had no cross-reactions with other potential interferents, including RSV, Flu A, and MP, confirming its specificity. The assay also exhibited good reproducibility, with coefficients of variation of 11.33% and 8.00% at different concentrations in pharyngeal swab samples. Additionally, the LOB and LOD in clinical samples were 31.59 pg/mL and 243.70 pg/mL and the correlation coefficient R<sup>2</sup> was 0.9784, which indicated that the method had good resistance to clinical interference. In this study, we successfully developed a sandwich TRFIA method based on the peptide aptamer B3-R001, which can be used to quantitatively measure the SARS-CoV-2 N protein level in pharyngeal swabs. Compared to antibodies, peptide aptamers are easily synthesized, inexpensive, and show great potential for clinical applications. This method provides a novel approach for rapidly detecting viral pathogens, contributing to the advancement of diagnostic tools.</p>","PeriodicalId":15800,"journal":{"name":"Journal of Fluorescence","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Fluorescence","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s10895-025-04199-w","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

This study, we employed computer-aided design to develop 27 peptide aptamers, and initially screened 11 candidates with binding energies less than - 6.0 kcal/mol. Subsequently, three peptide aptamers with strong specificity were selected using a direct time-resolved fluorescence immunoassay (TRFIA). Peptide aptamer B3, in combination with monoclonal antibody R001, was used to construct a TRFIA-based sandwich assay system. The performance of this system was evaluated concerning sensitivity, specificity, and reproducibility, and was further tested using 20 simulated pharyngeal swab samples. The dominant peptide aptamer, B3(RGQGVPI), was identified as the most promising candidate. This peptide demonstrated high specificity for the SARS-CoV-2 nucleocapsid (N) protein, with the lowest detectable concentration of 203.78 pg/mL. Importantly, the peptide had no cross-reactions with other potential interferents, including RSV, Flu A, and MP, confirming its specificity. The assay also exhibited good reproducibility, with coefficients of variation of 11.33% and 8.00% at different concentrations in pharyngeal swab samples. Additionally, the LOB and LOD in clinical samples were 31.59 pg/mL and 243.70 pg/mL and the correlation coefficient R2 was 0.9784, which indicated that the method had good resistance to clinical interference. In this study, we successfully developed a sandwich TRFIA method based on the peptide aptamer B3-R001, which can be used to quantitatively measure the SARS-CoV-2 N protein level in pharyngeal swabs. Compared to antibodies, peptide aptamers are easily synthesized, inexpensive, and show great potential for clinical applications. This method provides a novel approach for rapidly detecting viral pathogens, contributing to the advancement of diagnostic tools.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Fluorescence
Journal of Fluorescence 化学-分析化学
CiteScore
4.60
自引率
7.40%
发文量
203
审稿时长
5.4 months
期刊介绍: Journal of Fluorescence is an international forum for the publication of peer-reviewed original articles that advance the practice of this established spectroscopic technique. Topics covered include advances in theory/and or data analysis, studies of the photophysics of aromatic molecules, solvent, and environmental effects, development of stationary or time-resolved measurements, advances in fluorescence microscopy, imaging, photobleaching/recovery measurements, and/or phosphorescence for studies of cell biology, chemical biology and the advanced uses of fluorescence in flow cytometry/analysis, immunology, high throughput screening/drug discovery, DNA sequencing/arrays, genomics and proteomics. Typical applications might include studies of macromolecular dynamics and conformation, intracellular chemistry, and gene expression. The journal also publishes papers that describe the synthesis and characterization of new fluorophores, particularly those displaying unique sensitivities and/or optical properties. In addition to original articles, the Journal also publishes reviews, rapid communications, short communications, letters to the editor, topical news articles, and technical and design notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信