Comparison of Instrumented Mouthguard Post-Processing Methods.

IF 3 2区 医学 Q3 ENGINEERING, BIOMEDICAL
Ryan Gellner, Mark T Begonia, Matthew Wood, Lewis Rockwell, Taylor Geiman, Caitlyn Jung, Blake Gellner, Allison MacMartin, Sophia Manlapit, Steve Rowson
{"title":"Comparison of Instrumented Mouthguard Post-Processing Methods.","authors":"Ryan Gellner, Mark T Begonia, Matthew Wood, Lewis Rockwell, Taylor Geiman, Caitlyn Jung, Blake Gellner, Allison MacMartin, Sophia Manlapit, Steve Rowson","doi":"10.1007/s10439-025-03687-1","DOIUrl":null,"url":null,"abstract":"<p><p>Instrumented head acceleration measurement devices are commonly used in research studies to determine head acceleration exposure in certain populations. Instrumented mouthguards pair directly to the user's teeth and offer six-degree-of-freedom measurements. Though many studies have recently used these devices, post-processing techniques vary by study. Other studies have attempted to label impact quality or coupling status, also with varying methods. This study sought to compare the effect of post-processing and labeling methods on reported exposure distribution characteristics in instrumented mouthguard data from ice hockey players. We collected data from 18 female adolescent ice hockey players on two teams for an entire season. We then post-processed the measured signals using five different techniques: (1) the instrumented mouthguard manufacturer's data output, (2) a 500 Hz linear acceleration filter and a 300 Hz angular velocity filter, (3) HEADSport, (4) a 100 Hz linear acceleration filter and a 175 Hz angular velocity filter, and (5) a salvaging process to detect and remove decoupling based on signal frequency content. The post-processing techniques affected the reported exposure distributions by changing the mean, median, and 95th percentile values of peak linear and angular kinematics. We also compared labeling techniques by measuring agreement and inter-rater reliability between three labeling techniques: the instrumented mouthguard manufacturer's label, Luke et al.'s coupling label, and our classification learner that detects and labels decoupling. We found that the labeling techniques had low agreement about which acceleration events were the best to keep. Labeling technique also influenced the reported distributions' descriptive statistics. Post-processing and event labeling are crucial components of head acceleration event exposure studies. Methods should be described by researchers, and standardization should be sought to allow for better cross-study comparison. Published and publicly available techniques can help move the field toward this ideal. Researchers should be aware of the potential effect post-processing can have on a population's final reported exposure metrics.</p>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10439-025-03687-1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Instrumented head acceleration measurement devices are commonly used in research studies to determine head acceleration exposure in certain populations. Instrumented mouthguards pair directly to the user's teeth and offer six-degree-of-freedom measurements. Though many studies have recently used these devices, post-processing techniques vary by study. Other studies have attempted to label impact quality or coupling status, also with varying methods. This study sought to compare the effect of post-processing and labeling methods on reported exposure distribution characteristics in instrumented mouthguard data from ice hockey players. We collected data from 18 female adolescent ice hockey players on two teams for an entire season. We then post-processed the measured signals using five different techniques: (1) the instrumented mouthguard manufacturer's data output, (2) a 500 Hz linear acceleration filter and a 300 Hz angular velocity filter, (3) HEADSport, (4) a 100 Hz linear acceleration filter and a 175 Hz angular velocity filter, and (5) a salvaging process to detect and remove decoupling based on signal frequency content. The post-processing techniques affected the reported exposure distributions by changing the mean, median, and 95th percentile values of peak linear and angular kinematics. We also compared labeling techniques by measuring agreement and inter-rater reliability between three labeling techniques: the instrumented mouthguard manufacturer's label, Luke et al.'s coupling label, and our classification learner that detects and labels decoupling. We found that the labeling techniques had low agreement about which acceleration events were the best to keep. Labeling technique also influenced the reported distributions' descriptive statistics. Post-processing and event labeling are crucial components of head acceleration event exposure studies. Methods should be described by researchers, and standardization should be sought to allow for better cross-study comparison. Published and publicly available techniques can help move the field toward this ideal. Researchers should be aware of the potential effect post-processing can have on a population's final reported exposure metrics.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信