Enhanced Control Approach for PV Hybrid Energy Storage System With Supercapacitors Using Fuzzy MPPT Technique and Optimally Tuned Fractional Controllers

Energy Storage Pub Date : 2025-02-23 DOI:10.1002/est2.70147
Saswati Pattnaik, Mano Ranjan Kumar, Sunil Kumar Mishra, Shivam Prakash Gautam
{"title":"Enhanced Control Approach for PV Hybrid Energy Storage System With Supercapacitors Using Fuzzy MPPT Technique and Optimally Tuned Fractional Controllers","authors":"Saswati Pattnaik,&nbsp;Mano Ranjan Kumar,&nbsp;Sunil Kumar Mishra,&nbsp;Shivam Prakash Gautam","doi":"10.1002/est2.70147","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Hybrid energy storage systems (HESS) comprising supercapacitors and batteries in photovoltaic (PV) applications ensure overall system performance by compensating for their mutual drawbacks. However, the reliability of the PV-based HESS against frequent load variation and irregular solar irradiance demands a robust power management scheme (PMS) and associated control strategies. This paper presents an enhanced DC voltage stabilization control strategy for robust PMS for the PV-based HESS. The proposed control approach ensures stable DC link voltage regulation, improving the overall efficiency and thus reliability of the overall system. A comprehensive analysis of the system dynamics and control objectives is conducted under different operating conditions, leading to the development of a combined tilt-integral (TI) and fractional proportional-integral (FOPI)-based controller. The controller parameters are estimated using the particle swarm optimization (PSO) technique and a gradient-free Nelder–Mead simplex search (NMSS) algorithm for optimizing the time-domain parameters. Thereafter, the dynamic performance of the presented PMS is investigated through extensive experimentation analyzed in terms of various parameters. The investigation suggests that the proposed control scheme outperforms the conventional control approach by a significant margin of 60.81% and 40.42% in steady-state error and peak overshoot, respectively. Also, the state of charge (SOC) consumption of the battery is reduced by 8.46%, thus increasing the overall lifespan of the energy storage system. Therefore, the proposed control strategy offers a viable solution for ensuring stable and efficient operation of PV-based energy storage systems, contributing to the advancement of renewable energy integration and grid resilience.</p>\n </div>","PeriodicalId":11765,"journal":{"name":"Energy Storage","volume":"7 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Storage","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/est2.70147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Hybrid energy storage systems (HESS) comprising supercapacitors and batteries in photovoltaic (PV) applications ensure overall system performance by compensating for their mutual drawbacks. However, the reliability of the PV-based HESS against frequent load variation and irregular solar irradiance demands a robust power management scheme (PMS) and associated control strategies. This paper presents an enhanced DC voltage stabilization control strategy for robust PMS for the PV-based HESS. The proposed control approach ensures stable DC link voltage regulation, improving the overall efficiency and thus reliability of the overall system. A comprehensive analysis of the system dynamics and control objectives is conducted under different operating conditions, leading to the development of a combined tilt-integral (TI) and fractional proportional-integral (FOPI)-based controller. The controller parameters are estimated using the particle swarm optimization (PSO) technique and a gradient-free Nelder–Mead simplex search (NMSS) algorithm for optimizing the time-domain parameters. Thereafter, the dynamic performance of the presented PMS is investigated through extensive experimentation analyzed in terms of various parameters. The investigation suggests that the proposed control scheme outperforms the conventional control approach by a significant margin of 60.81% and 40.42% in steady-state error and peak overshoot, respectively. Also, the state of charge (SOC) consumption of the battery is reduced by 8.46%, thus increasing the overall lifespan of the energy storage system. Therefore, the proposed control strategy offers a viable solution for ensuring stable and efficient operation of PV-based energy storage systems, contributing to the advancement of renewable energy integration and grid resilience.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信