Estimation of Positive-, Negative-, and Zero-Sequence Current and Voltage Phasors of UIPC VSCs for Short-Circuit Faults in Transmission Lines

IF 1.8 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Babak Bahadori, Ali Nahavandi, Mahyar Abasi
{"title":"Estimation of Positive-, Negative-, and Zero-Sequence Current and Voltage Phasors of UIPC VSCs for Short-Circuit Faults in Transmission Lines","authors":"Babak Bahadori,&nbsp;Ali Nahavandi,&nbsp;Mahyar Abasi","doi":"10.1002/eng2.70006","DOIUrl":null,"url":null,"abstract":"<p>FACTS devices, functioning as controlled series voltage and parallel current source converters in transmission lines, can enhance network flexibility. The currents and voltages are regarded as unknown variables in the impedance estimation equations of the distance relay during fault occurrence. Typically, addressing the issues of protection systems for lines integrated with FACTS devices necessitates the development of a novel protection algorithm informed by the current line topology. A novel approach to address this difficulty involves employing an algorithm to estimate the injected current and voltage parameters of the series and parallel converters in FACTS devices. This research presents an estimation scheme utilizing artificial neural networks to determine the magnitude and phase angle of voltage and current in voltage source converters of the UIPC during short-circuit faults in transmission lines. The proposed approach has been designed for use across diverse locations, phases, resistances, and fault durations on both sides of the UIPC. The voltage and current magnitudes and angles for all three bus sequences on one side of the line, along with the voltage magnitude and angle of the equivalent circuit of the series converters and the current magnitude and angle of the shunt converter, have been recorded. The primary aim of this work is to introduce an estimation model derived from the measurement data of the bus and the UIPC converters. Ultimately, by employing the estimated phasors, the impedance and, consequently, the distance from the fault location to the relay may be accurately determined, eliminating the necessity to alter the configuration and formulation of the distance relay. The approach has undergone testing and evaluation for various short circuit scenarios on both sides of the UIPC under diverse conditions. The successful outcomes demonstrated in the simulation section indicate that the proposed technique effectively estimates the UIPC phasor during a fault.</p>","PeriodicalId":72922,"journal":{"name":"Engineering reports : open access","volume":"7 2","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/eng2.70006","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering reports : open access","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/eng2.70006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

FACTS devices, functioning as controlled series voltage and parallel current source converters in transmission lines, can enhance network flexibility. The currents and voltages are regarded as unknown variables in the impedance estimation equations of the distance relay during fault occurrence. Typically, addressing the issues of protection systems for lines integrated with FACTS devices necessitates the development of a novel protection algorithm informed by the current line topology. A novel approach to address this difficulty involves employing an algorithm to estimate the injected current and voltage parameters of the series and parallel converters in FACTS devices. This research presents an estimation scheme utilizing artificial neural networks to determine the magnitude and phase angle of voltage and current in voltage source converters of the UIPC during short-circuit faults in transmission lines. The proposed approach has been designed for use across diverse locations, phases, resistances, and fault durations on both sides of the UIPC. The voltage and current magnitudes and angles for all three bus sequences on one side of the line, along with the voltage magnitude and angle of the equivalent circuit of the series converters and the current magnitude and angle of the shunt converter, have been recorded. The primary aim of this work is to introduce an estimation model derived from the measurement data of the bus and the UIPC converters. Ultimately, by employing the estimated phasors, the impedance and, consequently, the distance from the fault location to the relay may be accurately determined, eliminating the necessity to alter the configuration and formulation of the distance relay. The approach has undergone testing and evaluation for various short circuit scenarios on both sides of the UIPC under diverse conditions. The successful outcomes demonstrated in the simulation section indicate that the proposed technique effectively estimates the UIPC phasor during a fault.

Abstract Image

FACTS 设备是输电线路中的受控串联电压源和并联电流源转换器,可提高网络的灵活性。在故障发生时,电流和电压被视为距离继电器阻抗估算方程中的未知变量。通常情况下,要解决集成了 FACTS 设备的线路保护系统问题,就必须根据当前的线路拓扑结构开发一种新的保护算法。解决这一难题的新方法是采用一种算法来估算 FACTS 设备中串联和并联变流器的注入电流和电压参数。本研究提出了一种估算方案,利用人工神经网络确定输电线路短路故障期间 UIPC 电压源转换器中电压和电流的幅值和相位角。所提出的方法适用于 UIPC 两侧不同的位置、相位、电阻和故障持续时间。已记录了线路一侧所有三个母线序列的电压和电流大小和角度,以及串联变流器等效电路的电压大小和角度和并联变流器的电流大小和角度。这项工作的主要目的是引入一个根据母线和 UIPC 变流器测量数据得出的估算模型。最终,通过使用估算的相位,可以准确地确定阻抗以及故障位置到继电器的距离,从而无需改变距离继电器的配置和配方。该方法在不同条件下对 UIPC 两侧的各种短路情况进行了测试和评估。模拟部分所展示的成功结果表明,所提出的技术能在故障期间有效估计 UIPC 相位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
0.00%
发文量
0
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信