Investigating the Evolution of arch temperature and prediction model for temperature rise of fire Smoke: Model testing of an Extra-Long highway tunnel with vertical shaft

IF 2.6 3区 工程技术 Q2 ENGINEERING, MECHANICAL
Hui Li , Yuqing Xie , Zhiqiang Zhang , Rongjie Li , Heng Zhang
{"title":"Investigating the Evolution of arch temperature and prediction model for temperature rise of fire Smoke: Model testing of an Extra-Long highway tunnel with vertical shaft","authors":"Hui Li ,&nbsp;Yuqing Xie ,&nbsp;Zhiqiang Zhang ,&nbsp;Rongjie Li ,&nbsp;Heng Zhang","doi":"10.1016/j.ijheatfluidflow.2025.109781","DOIUrl":null,"url":null,"abstract":"<div><div>In order to investigate the characteristics of the arch temperature distribution of extra-long highway tunnel fire under the action of vertical shaft mechanical smoke exhaust, relying on the Yunshan Tunnel in Shanxi Province to carry out the physical model test of tunnel fire scaling under the vertical shaft mechanical smoke exhaust, to explore the influence of the vertical shaft structural parameters on the longitudinal temperature distribution of the tunnel, as well as the characteristics of the upstream and downstream tunnel smoke outlet attenuation of the temperature of the arch in the conditions of the different fire power and fire position, the results show that: the diameter of the shaft and the height of the smoke outlet upstream temperature has less influence on the temperature of the tunnel smoke outlet. The results show that the diameter and height of the shaft have less influence on the upstream temperature of the smoke outlet. For the downstream of the smoke outlet, the larger the diameter of the shaft, the faster the arch temperature decreases; the higher the height of the shaft, the lower the arch temperature at the downstream measurement points. The arch temperature upstream of the smoke outlet shows a significant exponential attenuation trend for different fire power and location, and the influence of smoke exhaust speed on the temperature attenuation is extremely small when the fire source is far away from the smoke outlet. On the contrary, the temperature attenuation of the arch downstream of the smoke outlet was significantly affected by the smoke exhaust speed and was not sensitive to the change of the distance between the fire source and the smoke outlet. At low wind speeds (≤13 m/s), the downstream temperature followed an exponential attenuation; while at high wind speeds (15 m/s), the attenuation pattern shifted to linear. Predictive equations for the temperature rise in the upstream and downstream arches of the smoke outlet were fitted for 94.9 kW and 158.1 kW fire power, which provided a theoretical basis for fire safety assessment.</div></div>","PeriodicalId":335,"journal":{"name":"International Journal of Heat and Fluid Flow","volume":"113 ","pages":"Article 109781"},"PeriodicalIF":2.6000,"publicationDate":"2025-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Heat and Fluid Flow","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142727X25000396","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In order to investigate the characteristics of the arch temperature distribution of extra-long highway tunnel fire under the action of vertical shaft mechanical smoke exhaust, relying on the Yunshan Tunnel in Shanxi Province to carry out the physical model test of tunnel fire scaling under the vertical shaft mechanical smoke exhaust, to explore the influence of the vertical shaft structural parameters on the longitudinal temperature distribution of the tunnel, as well as the characteristics of the upstream and downstream tunnel smoke outlet attenuation of the temperature of the arch in the conditions of the different fire power and fire position, the results show that: the diameter of the shaft and the height of the smoke outlet upstream temperature has less influence on the temperature of the tunnel smoke outlet. The results show that the diameter and height of the shaft have less influence on the upstream temperature of the smoke outlet. For the downstream of the smoke outlet, the larger the diameter of the shaft, the faster the arch temperature decreases; the higher the height of the shaft, the lower the arch temperature at the downstream measurement points. The arch temperature upstream of the smoke outlet shows a significant exponential attenuation trend for different fire power and location, and the influence of smoke exhaust speed on the temperature attenuation is extremely small when the fire source is far away from the smoke outlet. On the contrary, the temperature attenuation of the arch downstream of the smoke outlet was significantly affected by the smoke exhaust speed and was not sensitive to the change of the distance between the fire source and the smoke outlet. At low wind speeds (≤13 m/s), the downstream temperature followed an exponential attenuation; while at high wind speeds (15 m/s), the attenuation pattern shifted to linear. Predictive equations for the temperature rise in the upstream and downstream arches of the smoke outlet were fitted for 94.9 kW and 158.1 kW fire power, which provided a theoretical basis for fire safety assessment.
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Heat and Fluid Flow
International Journal of Heat and Fluid Flow 工程技术-工程:机械
CiteScore
5.00
自引率
7.70%
发文量
131
审稿时长
33 days
期刊介绍: The International Journal of Heat and Fluid Flow welcomes high-quality original contributions on experimental, computational, and physical aspects of convective heat transfer and fluid dynamics relevant to engineering or the environment, including multiphase and microscale flows. Papers reporting the application of these disciplines to design and development, with emphasis on new technological fields, are also welcomed. Some of these new fields include microscale electronic and mechanical systems; medical and biological systems; and thermal and flow control in both the internal and external environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信