Face and Content Validity of Farra Eye Model as a Surgical Simulator for Capsulorhexis Training.

Journal of CME Pub Date : 2025-02-17 eCollection Date: 2025-01-01 DOI:10.1080/28338073.2025.2467566
Hanifah Rahmani Nursanti, Julie Dewi Barliana, Syska Widyawati, Faraby Martha, Levina Chandra Khoe
{"title":"Face and Content Validity of Farra Eye Model as a Surgical Simulator for Capsulorhexis Training.","authors":"Hanifah Rahmani Nursanti, Julie Dewi Barliana, Syska Widyawati, Faraby Martha, Levina Chandra Khoe","doi":"10.1080/28338073.2025.2467566","DOIUrl":null,"url":null,"abstract":"<p><p>Several simulation models are available for cataract surgery training, but they have limitations in terms of quality and availability. The Farra Eye Model, a new cataract surgery simulator, was developed using 3D-printing technology to provide residents with more options. This study aims to determine its face and content validity as a surgical simulator for training capsulorhexis, a crucial step in cataract surgery. Ophthalmology residents and consultants at the Faculty of Medicine, Universitas Indonesia, were asked to complete three capsulorhexis tasks in the eye model. Then, subjects were surveyed using a validated questionnaire to assess the face and content validity of the model. Responses were recorded using a 5-point Likert scale ranging from (1) disagree to (5) strongly agree. Twenty-two subjects completed the tasks. The overall face validity score was favourable (3.67 ± 0.67). However, the resident group considered capsule elasticity poor (2.73 ± 1.1), while the consultant group still felt it realistic (3.64 ± 0.9). The content validity had a favourable score in the overall assessment (4.15 ± 0.58) and for each assessment component. Despite the challenge of replicating human lens capsule elasticity, the Farra Eye Model demonstrates initial evidence supporting its use for capsulorhexis training. It can be helpful for training programs with limited access to commercially available simulation models.</p>","PeriodicalId":73675,"journal":{"name":"Journal of CME","volume":"14 1","pages":"2467566"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11837912/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of CME","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/28338073.2025.2467566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Several simulation models are available for cataract surgery training, but they have limitations in terms of quality and availability. The Farra Eye Model, a new cataract surgery simulator, was developed using 3D-printing technology to provide residents with more options. This study aims to determine its face and content validity as a surgical simulator for training capsulorhexis, a crucial step in cataract surgery. Ophthalmology residents and consultants at the Faculty of Medicine, Universitas Indonesia, were asked to complete three capsulorhexis tasks in the eye model. Then, subjects were surveyed using a validated questionnaire to assess the face and content validity of the model. Responses were recorded using a 5-point Likert scale ranging from (1) disagree to (5) strongly agree. Twenty-two subjects completed the tasks. The overall face validity score was favourable (3.67 ± 0.67). However, the resident group considered capsule elasticity poor (2.73 ± 1.1), while the consultant group still felt it realistic (3.64 ± 0.9). The content validity had a favourable score in the overall assessment (4.15 ± 0.58) and for each assessment component. Despite the challenge of replicating human lens capsule elasticity, the Farra Eye Model demonstrates initial evidence supporting its use for capsulorhexis training. It can be helpful for training programs with limited access to commercially available simulation models.

Farra眼模型作为撕囊术训练手术模拟器的面部和内容效度。
目前已有几种模拟模型可用于白内障手术培训,但它们在质量和可用性方面存在局限性。Farra眼模型是一种新型白内障手术模拟器,使用3d打印技术开发,为患者提供更多选择。本研究旨在确定其外观和内容的有效性,作为训练撕囊术的手术模拟器,这是白内障手术的关键步骤。印度尼西亚大学医学院的眼科住院医师和顾问被要求在眼模型中完成三个撕囊任务。然后,使用一份有效的问卷对被试进行调查,以评估模型的面部和内容效度。回答是用李克特5分量表记录的,从(1)不同意到(5)非常同意。22名受试者完成了这些任务。整体面部效度评分为有利(3.67±0.67)。然而,居民组认为胶囊弹性差(2.73±1.1),而咨询组仍认为可行(3.64±0.9)。内容效度在总体评价(4.15±0.58)和各评价分量上得分均较好。尽管复制人类晶状体囊弹性的挑战,法拉眼模型显示初步证据支持其用于撕囊训练。它可以帮助与有限的访问商业上可用的仿真模型的培训计划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信