Effect of neonatal intensive care unit design on infants with Neonatal Opioid Withdrawal Syndrome.

Q2 Medicine
Journal of neonatal-perinatal medicine Pub Date : 2025-01-01 Epub Date: 2024-11-05 DOI:10.1177/19345798241296324
Katherine Nyman, Elyse Decker, Kristin Ronan, Mathangi Gopalakrishnan, Dina El-Metwally
{"title":"Effect of neonatal intensive care unit design on infants with Neonatal Opioid Withdrawal Syndrome.","authors":"Katherine Nyman, Elyse Decker, Kristin Ronan, Mathangi Gopalakrishnan, Dina El-Metwally","doi":"10.1177/19345798241296324","DOIUrl":null,"url":null,"abstract":"<p><p>Background/ObjectiveNeonatal Opioid Withdrawal Syndrome (NOWS) requires advanced and often prolonged medical care in the neonatal intensive care unit (NICU). We examined the effect of NICU design on treatment and NICU length of stay (NICU-LOS) for infants with NOWS.MethodsA retrospective chart review of eligible infants with NOWS was conducted from 2013 to 2018. We collected and analyzed data on demographics, medication, and NICU-LOS characteristics. A multivariable linear regression on log-transformed NICU-LOS was performed for comparison between the open-bay design (OBD) for 2013-2015 (August) and the new single-family-room (SFR) NICU for September 2015-2018.ResultsThere were 118 neonates analyzed in OBD and 138 neonates in the SFR. Among infants in the SFR NICU, 86% received pharmacotherapy, compared to 76% of infants in the OBD (<i>p</i> = 0.059). The breastfeeding rate was 26% in the SFR and 6% in the OBD (<i>p</i> =< 0.001 ). Infants in the SFR NICU had 1.3 times longer mean NICU-LOS (<i>p</i> = 0.0163) than infants in OBD after adjusting for covariates including small for gestational age. The median (1Q, 3Q) cumulative doses of morphine (mg/kg) among the SFR and OBD groups were 6.4 (2.3,17.3) and 8.7 (3.2,19.3) <i>p</i>: NS, respectively.ConclusionsThe SFR NICU was associated with longer NICU-LOS for infants with NOWS despite higher rates of breastfeeding and no difference in morphine dosage. While providing more privacy and possible improved patient satisfaction, there may be unintended consequences of the SFR design.</p>","PeriodicalId":16537,"journal":{"name":"Journal of neonatal-perinatal medicine","volume":" ","pages":"46-51"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neonatal-perinatal medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19345798241296324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background/ObjectiveNeonatal Opioid Withdrawal Syndrome (NOWS) requires advanced and often prolonged medical care in the neonatal intensive care unit (NICU). We examined the effect of NICU design on treatment and NICU length of stay (NICU-LOS) for infants with NOWS.MethodsA retrospective chart review of eligible infants with NOWS was conducted from 2013 to 2018. We collected and analyzed data on demographics, medication, and NICU-LOS characteristics. A multivariable linear regression on log-transformed NICU-LOS was performed for comparison between the open-bay design (OBD) for 2013-2015 (August) and the new single-family-room (SFR) NICU for September 2015-2018.ResultsThere were 118 neonates analyzed in OBD and 138 neonates in the SFR. Among infants in the SFR NICU, 86% received pharmacotherapy, compared to 76% of infants in the OBD (p = 0.059). The breastfeeding rate was 26% in the SFR and 6% in the OBD (p =< 0.001 ). Infants in the SFR NICU had 1.3 times longer mean NICU-LOS (p = 0.0163) than infants in OBD after adjusting for covariates including small for gestational age. The median (1Q, 3Q) cumulative doses of morphine (mg/kg) among the SFR and OBD groups were 6.4 (2.3,17.3) and 8.7 (3.2,19.3) p: NS, respectively.ConclusionsThe SFR NICU was associated with longer NICU-LOS for infants with NOWS despite higher rates of breastfeeding and no difference in morphine dosage. While providing more privacy and possible improved patient satisfaction, there may be unintended consequences of the SFR design.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of neonatal-perinatal medicine
Journal of neonatal-perinatal medicine Medicine-Pediatrics, Perinatology and Child Health
CiteScore
2.00
自引率
0.00%
发文量
124
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信