Chloride induced corrosion behaviour of mild steel rebars: A case study of calcined Clay Pozzolan containing concrete

IF 2.7 Q2 MULTIDISCIPLINARY SCIENCES
Lucas Nana Wiredu Damoah , Richard Nii Ayitey Akoto , Bernard Kwame Mussey , Yaw Delali Bensah
{"title":"Chloride induced corrosion behaviour of mild steel rebars: A case study of calcined Clay Pozzolan containing concrete","authors":"Lucas Nana Wiredu Damoah ,&nbsp;Richard Nii Ayitey Akoto ,&nbsp;Bernard Kwame Mussey ,&nbsp;Yaw Delali Bensah","doi":"10.1016/j.sciaf.2025.e02592","DOIUrl":null,"url":null,"abstract":"<div><div>The partial replacement of 5 – 30 % by mass of ordinary Portland cement with clay pozzolana in concrete, gives impressive chemical characteristics to the resulting material. Corrosion behavior of reinforcement steel in two types of concrete mixtures: Ordinary Portland Cement (OPC) containing concrete and 30 % clay pozzolana cement (PPC) containing concrete are studied. These concretes were exposed to 3 % and 5 % (w/v) solutions of NaCl as corrosion acceleration media. Electrochemical polarization measurements were performed for 3, 7, 15, and 23 days. The corrosion rate obtained from the polarization curves revealed that samples exposed to 5 %(w/v) NaCl had higher corrosion rates than those exposed to 3 %(w/v) NaCl. The addition of 30 % clay pozzolan as a partial replacement for OPC in concrete resulted in an average reduction in the corrosion rate of approximately 90 % in 3 %(w/v) NaCl and 74 % in 5 %(w/v) NaCl over 23 days.</div></div>","PeriodicalId":21690,"journal":{"name":"Scientific African","volume":"27 ","pages":"Article e02592"},"PeriodicalIF":2.7000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientific African","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468227625000626","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The partial replacement of 5 – 30 % by mass of ordinary Portland cement with clay pozzolana in concrete, gives impressive chemical characteristics to the resulting material. Corrosion behavior of reinforcement steel in two types of concrete mixtures: Ordinary Portland Cement (OPC) containing concrete and 30 % clay pozzolana cement (PPC) containing concrete are studied. These concretes were exposed to 3 % and 5 % (w/v) solutions of NaCl as corrosion acceleration media. Electrochemical polarization measurements were performed for 3, 7, 15, and 23 days. The corrosion rate obtained from the polarization curves revealed that samples exposed to 5 %(w/v) NaCl had higher corrosion rates than those exposed to 3 %(w/v) NaCl. The addition of 30 % clay pozzolan as a partial replacement for OPC in concrete resulted in an average reduction in the corrosion rate of approximately 90 % in 3 %(w/v) NaCl and 74 % in 5 %(w/v) NaCl over 23 days.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Scientific African
Scientific African Multidisciplinary-Multidisciplinary
CiteScore
5.60
自引率
3.40%
发文量
332
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信