In vivo efficacy of a refillable intrawound drug delivery device in a sheep model of biofilm-compromised open fracture-related infection

IF 5.9 Q1 MICROBIOLOGY
Dustin Williams , David Rothberg , Walker Kay , Lisa Nehring , Robert Falconer , Richard Tyler Epperson , Brooke Kawaguchi , Carolyn Ardizzone , Brian Barnum , Nicholas Ashton
{"title":"In vivo efficacy of a refillable intrawound drug delivery device in a sheep model of biofilm-compromised open fracture-related infection","authors":"Dustin Williams ,&nbsp;David Rothberg ,&nbsp;Walker Kay ,&nbsp;Lisa Nehring ,&nbsp;Robert Falconer ,&nbsp;Richard Tyler Epperson ,&nbsp;Brooke Kawaguchi ,&nbsp;Carolyn Ardizzone ,&nbsp;Brian Barnum ,&nbsp;Nicholas Ashton","doi":"10.1016/j.bioflm.2025.100262","DOIUrl":null,"url":null,"abstract":"<div><div>Open fracture-related infection challenges persist in healthcare. From the time open fractures were defined ∼50 years ago, infection rates have gone essentially unchanged. Contributing factors include compromised vasculature, biofilm, and stalled innovations in treatment and prophylaxis. In this study, we engineered and tested the efficacy of a refillable drug delivery device, the Purgo Pouch (Pouch), that sustains local, high dose intrawound antibiotic concentrations in wound sites. We hypothesized that it would manage biofilm-compromised open fracture-related infection better than clinical standards of care. Therapies were tested in a unique sheep model of long bone open fracture-related infection with compromised tissue and biofilm inocula of methicillin-resistant <em>Staphylococcus aureus</em>. Sheep (n = 5/group) were treated with IV vancomycin (10 days), gentamicin-loaded CaSO<sub>4</sub> beads (single application), or the Pouch (10 days) loaded with gentamicin alone or a triple antibiotic combination. At 21 days, sheep were euthanized and microbiological and histological data collected. Results indicated that the Pouch managed infection more effectively, reducing bioburden to &lt;10<sup>5</sup> colony forming units (CFU)/sample, which was statistically significant compared to clinical standards, which failed to reduce bioburden to below 10<sup>5</sup> CFU. The hypothesis was supported. The Pouch received Breakthrough Device Designation by the FDA, is being transitioned toward clinical trials, and is a potential solution to the long-standing problem of open fracture-related infection.</div></div>","PeriodicalId":55844,"journal":{"name":"Biofilm","volume":"9 ","pages":"Article 100262"},"PeriodicalIF":5.9000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biofilm","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590207525000103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Open fracture-related infection challenges persist in healthcare. From the time open fractures were defined ∼50 years ago, infection rates have gone essentially unchanged. Contributing factors include compromised vasculature, biofilm, and stalled innovations in treatment and prophylaxis. In this study, we engineered and tested the efficacy of a refillable drug delivery device, the Purgo Pouch (Pouch), that sustains local, high dose intrawound antibiotic concentrations in wound sites. We hypothesized that it would manage biofilm-compromised open fracture-related infection better than clinical standards of care. Therapies were tested in a unique sheep model of long bone open fracture-related infection with compromised tissue and biofilm inocula of methicillin-resistant Staphylococcus aureus. Sheep (n = 5/group) were treated with IV vancomycin (10 days), gentamicin-loaded CaSO4 beads (single application), or the Pouch (10 days) loaded with gentamicin alone or a triple antibiotic combination. At 21 days, sheep were euthanized and microbiological and histological data collected. Results indicated that the Pouch managed infection more effectively, reducing bioburden to <105 colony forming units (CFU)/sample, which was statistically significant compared to clinical standards, which failed to reduce bioburden to below 105 CFU. The hypothesis was supported. The Pouch received Breakthrough Device Designation by the FDA, is being transitioned toward clinical trials, and is a potential solution to the long-standing problem of open fracture-related infection.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biofilm
Biofilm MICROBIOLOGY-
CiteScore
7.50
自引率
1.50%
发文量
30
审稿时长
57 days
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信