CT-Based Machine Learning Radiomics Analysis to Diagnose Dysthyroid Optic Neuropathy.

IF 1.9 4区 医学 Q2 OPHTHALMOLOGY
Lan Ma, Xue Jiang, Xuan Yang, Minghui Wang, Zhijia Hou, Ju Zhang, Dongmei Li
{"title":"CT-Based Machine Learning Radiomics Analysis to Diagnose Dysthyroid Optic Neuropathy.","authors":"Lan Ma, Xue Jiang, Xuan Yang, Minghui Wang, Zhijia Hou, Ju Zhang, Dongmei Li","doi":"10.1080/08820538.2025.2463948","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop CT-based machine learning radiomics models used for the diagnosis of dysthyroid optic neuropathy (DON).</p><p><strong>Materials and methods: </strong>This is a retrospective study included 57 patients (114 orbits) diagnosed with thyroid-associated ophthalmopathy (TAO) at the Beijing Tongren Hospital between December 2019 and June 2023. CT scans, medical history, examination results, and clinical data of the participants were collected. DON was diagnosed based on clinical manifestations and examinations. The DON orbits and non-DON orbits were then divided into a training set and a test set at a ratio of approximately 7:3. The 3D slicer software was used to identify the volumes of interest (VOI). Radiomics features were extracted using the Pyradiomics and selected by t-test and least absolute shrinkage and selection operator (LASSO) regression algorithm with 10-fold cross-validation. Machine-learning models, including random forest (RF) model, support vector machine (SVM) model, and logistic regression (LR) model were built and validated by receiver operating characteristic (ROC) curves, area under the curves (AUC) and confusion matrix-related data. The net benefit of the models is shown by the decision curve analysis (DCA).</p><p><strong>Results: </strong>We extracted 107 features from the imaging data, representing various image information of the optic nerve and surrounding orbital tissues. Using the LASSO method, we identified the five most informative features. The AUC ranged from 0.77 to 0.80 in the training set and the AUC of the RF, SVM and LR models based on the features were 0.86, 0.80 and 0.83 in the test set, respectively. The DeLong test showed there was no significant difference between the three models (RF model vs SVM model: <i>p</i> = .92; RF model vs LR model: <i>p</i> = .94; SVM model vs LR model: <i>p</i> = .98) and the models showed optimal clinical efficacy in DCA.</p><p><strong>Conclusions: </strong>The CT-based machine learning radiomics analysis exhibited excellent ability to diagnose DON and may enhance diagnostic convenience.</p>","PeriodicalId":21702,"journal":{"name":"Seminars in Ophthalmology","volume":" ","pages":"1-7"},"PeriodicalIF":1.9000,"publicationDate":"2025-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08820538.2025.2463948","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To develop CT-based machine learning radiomics models used for the diagnosis of dysthyroid optic neuropathy (DON).

Materials and methods: This is a retrospective study included 57 patients (114 orbits) diagnosed with thyroid-associated ophthalmopathy (TAO) at the Beijing Tongren Hospital between December 2019 and June 2023. CT scans, medical history, examination results, and clinical data of the participants were collected. DON was diagnosed based on clinical manifestations and examinations. The DON orbits and non-DON orbits were then divided into a training set and a test set at a ratio of approximately 7:3. The 3D slicer software was used to identify the volumes of interest (VOI). Radiomics features were extracted using the Pyradiomics and selected by t-test and least absolute shrinkage and selection operator (LASSO) regression algorithm with 10-fold cross-validation. Machine-learning models, including random forest (RF) model, support vector machine (SVM) model, and logistic regression (LR) model were built and validated by receiver operating characteristic (ROC) curves, area under the curves (AUC) and confusion matrix-related data. The net benefit of the models is shown by the decision curve analysis (DCA).

Results: We extracted 107 features from the imaging data, representing various image information of the optic nerve and surrounding orbital tissues. Using the LASSO method, we identified the five most informative features. The AUC ranged from 0.77 to 0.80 in the training set and the AUC of the RF, SVM and LR models based on the features were 0.86, 0.80 and 0.83 in the test set, respectively. The DeLong test showed there was no significant difference between the three models (RF model vs SVM model: p = .92; RF model vs LR model: p = .94; SVM model vs LR model: p = .98) and the models showed optimal clinical efficacy in DCA.

Conclusions: The CT-based machine learning radiomics analysis exhibited excellent ability to diagnose DON and may enhance diagnostic convenience.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Seminars in Ophthalmology
Seminars in Ophthalmology OPHTHALMOLOGY-
CiteScore
3.20
自引率
0.00%
发文量
80
审稿时长
>12 weeks
期刊介绍: Seminars in Ophthalmology offers current, clinically oriented reviews on the diagnosis and treatment of ophthalmic disorders. Each issue focuses on a single topic, with a primary emphasis on appropriate surgical techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信