A randomised controlled trial comparing three clinical administration strategies in spectral detector CT pulmonary angiography with low contrast medium dose.

IF 4.7 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Cathrine Helgestad Kristiansen, Owen Thomas, Anton Bengt Nyquist, Audun Sanderud, Joao Boavida, Jonn Terje Geitung, Thien Trung Tran, Peter Mæhre Lauritzen
{"title":"A randomised controlled trial comparing three clinical administration strategies in spectral detector CT pulmonary angiography with low contrast medium dose.","authors":"Cathrine Helgestad Kristiansen, Owen Thomas, Anton Bengt Nyquist, Audun Sanderud, Joao Boavida, Jonn Terje Geitung, Thien Trung Tran, Peter Mæhre Lauritzen","doi":"10.1007/s00330-025-11420-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To compare vascular attenuation (VA) with three strategies for administering a low contrast medium (CM) dose in dual-layer spectral detector CT pulmonary angiography (CTPA).</p><p><strong>Methods: </strong>Patients were prospectively randomised into control- or one of two experimental groups. Control group patients received CM (350 mgI/mL) diluted 1:1 with saline. Experimental group B received CM (350 mgI/mL) with low flow. Experimental group C received CM with low concentration (140 mgI/mL). Virtual monoenergetic images at 40 and 55 kiloelectron Volt (keV) were reconstructed. Objective examination quality (OEQ) i.e., VA, noise, and signal-to-noise ratio, was measured and subjective examination quality (SEQ) was rated at three anatomical levels: in the pulmonary trunk (PT), the interlobar arteries and the posterior basal segmental arteries.</p><p><strong>Primary outcome: </strong>VA in PT at 40 keV.</p><p><strong>Secondary outcomes: </strong>OEQ and SEQ across all anatomic levels.</p><p><strong>Results: </strong>A total of 328 patients were randomised. 112 vs 115 and 101 were analysed in the control (A) vs experimental groups (B and C), respectively. There were no differences in VA in PT between the groups: A vs B (p = 0.96), B vs C (p = 0.14), and A vs C (p = 0.18). Group C showed higher VA across all anatomical levels. There were no differences in SEQ.</p><p><strong>Conclusion: </strong>There was no difference in the attenuation in the PT between the dilution-, low flow-, and low concentration groups. However, the low concentration group showed higher attenuation in the pulmonary arteries when all anatomical levels were assessed.</p><p><strong>Key points: </strong>Question Contrast medium reduction may be accomplished with dilution, low flow, or low concentration. However, the effect of the different strategies on vascular attenuation is unknown. Findings There was no difference in pulmonary trunk attenuation between the three strategies on spectral detector CT pulmonary angiography. Clinical relevance Low contrast medium dose spectral detector CT pulmonary angiography may be implemented with the administration strategy of the unit's own choice.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2025-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-025-11420-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To compare vascular attenuation (VA) with three strategies for administering a low contrast medium (CM) dose in dual-layer spectral detector CT pulmonary angiography (CTPA).

Methods: Patients were prospectively randomised into control- or one of two experimental groups. Control group patients received CM (350 mgI/mL) diluted 1:1 with saline. Experimental group B received CM (350 mgI/mL) with low flow. Experimental group C received CM with low concentration (140 mgI/mL). Virtual monoenergetic images at 40 and 55 kiloelectron Volt (keV) were reconstructed. Objective examination quality (OEQ) i.e., VA, noise, and signal-to-noise ratio, was measured and subjective examination quality (SEQ) was rated at three anatomical levels: in the pulmonary trunk (PT), the interlobar arteries and the posterior basal segmental arteries.

Primary outcome: VA in PT at 40 keV.

Secondary outcomes: OEQ and SEQ across all anatomic levels.

Results: A total of 328 patients were randomised. 112 vs 115 and 101 were analysed in the control (A) vs experimental groups (B and C), respectively. There were no differences in VA in PT between the groups: A vs B (p = 0.96), B vs C (p = 0.14), and A vs C (p = 0.18). Group C showed higher VA across all anatomical levels. There were no differences in SEQ.

Conclusion: There was no difference in the attenuation in the PT between the dilution-, low flow-, and low concentration groups. However, the low concentration group showed higher attenuation in the pulmonary arteries when all anatomical levels were assessed.

Key points: Question Contrast medium reduction may be accomplished with dilution, low flow, or low concentration. However, the effect of the different strategies on vascular attenuation is unknown. Findings There was no difference in pulmonary trunk attenuation between the three strategies on spectral detector CT pulmonary angiography. Clinical relevance Low contrast medium dose spectral detector CT pulmonary angiography may be implemented with the administration strategy of the unit's own choice.

一项随机对照试验,比较了低造影剂剂量光谱探测器 CT 肺血管造影术中的三种临床用药策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Radiology
European Radiology 医学-核医学
CiteScore
11.60
自引率
8.50%
发文量
874
审稿时长
2-4 weeks
期刊介绍: European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field. This is the Journal of the European Society of Radiology, and the official journal of a number of societies. From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信