{"title":"A New Multifunction Oxygenator With a Dual-Chamber Gas Exchanger to Reduce Dependence on Oxygen Supply.","authors":"Dong Han, Jiafeng Zhang, Aakash Shah, Bartley P Griffith, Zhongjun J Wu","doi":"10.1097/MAT.0000000000002396","DOIUrl":null,"url":null,"abstract":"<p><p>Although extracorporeal membrane oxygenation (ECMO) systems have been used to provide temporary support for patients with severe respiratory or cardiac failure, they are often bedridden, in part because of their bulky size which relies solely on an unlimited source of wall oxygen. However, there is an unmet clinical need for ambulatory ECMO which necessitates downsizing the ECMO system. We sought to develop a new oxygenator to reduce the dependence on the oxygen supply source. The proposed oxygenator features a dual-chamber gas exchangers, with one chamber primarily responsible for carbon dioxide removal using ambient air and a subsequent chamber primarily responsible for oxygen transfer using pure oxygen. Computational fluid dynamics was used to analyze the blood flow field to avoid adverse stagnation and optimize gas exchange performance. Bovine blood was used for in vitro gas transfer test. This new oxygenator demonstrated the capability to provide adequate respiratory support (both carbon dioxide removal and oxygen transfer) to adult patients at blood rate of 4-6 L/min with an oxygen supply of only 2 L/min. The reduced use of oxygen with this new oxygenator may pave the way for the development of potable ECMO systems.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002396","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Although extracorporeal membrane oxygenation (ECMO) systems have been used to provide temporary support for patients with severe respiratory or cardiac failure, they are often bedridden, in part because of their bulky size which relies solely on an unlimited source of wall oxygen. However, there is an unmet clinical need for ambulatory ECMO which necessitates downsizing the ECMO system. We sought to develop a new oxygenator to reduce the dependence on the oxygen supply source. The proposed oxygenator features a dual-chamber gas exchangers, with one chamber primarily responsible for carbon dioxide removal using ambient air and a subsequent chamber primarily responsible for oxygen transfer using pure oxygen. Computational fluid dynamics was used to analyze the blood flow field to avoid adverse stagnation and optimize gas exchange performance. Bovine blood was used for in vitro gas transfer test. This new oxygenator demonstrated the capability to provide adequate respiratory support (both carbon dioxide removal and oxygen transfer) to adult patients at blood rate of 4-6 L/min with an oxygen supply of only 2 L/min. The reduced use of oxygen with this new oxygenator may pave the way for the development of potable ECMO systems.
期刊介绍:
ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world.
The official publication of the American Society for Artificial Internal Organs.