Geothermal energy-assisted pumped thermal energy storage: Configuration mapping

IF 9.9 1区 工程技术 Q1 ENERGY & FUELS
Suzhen Yin, Chuangang Bai, Kaiyue Zheng, Yilun Zhang, Xingpeng Yan, Zhan Liu
{"title":"Geothermal energy-assisted pumped thermal energy storage: Configuration mapping","authors":"Suzhen Yin,&nbsp;Chuangang Bai,&nbsp;Kaiyue Zheng,&nbsp;Yilun Zhang,&nbsp;Xingpeng Yan,&nbsp;Zhan Liu","doi":"10.1016/j.enconman.2025.119660","DOIUrl":null,"url":null,"abstract":"<div><div>Unstable renewable energy sources, including wind and photovoltaic power generation with the inherent characteristics of intermittency and randomness, pose an extremely significant challenges to the safety and stability of electrical grids. Considered a viable solution, energy storage technology increases the flexibility and regulatory capacity of power grids by storing and releasing excess electricity at different times. Pump thermal energy storage technology offers an efficient large-scale electricity storage solution that is completely free from geographical location limitations. Skillfully integrating pumped thermal energy storage technology with low-grade heat can effectively improve its thermodynamic and economic performance. To significantly enhance the utilization rate of geothermal energy and effectively achieve a more optimal performance of pumped thermal energy storage systems, the in-depth and comprehensive study conducted a thermo-economic evaluation of 15 types of geothermal-assisted transcritical pumped thermal energy storage systems. This study provides configuration selection maps for the round trip efficiency and the levelized cost of storage, thereby enabling an extremely effective and swift evaluation of the performance of these various configuration systems. When the geothermal temperature changes within the range from 50 °C to 90 °C, the efficiency of the systems that are considered to be the most suitable under these conditions varies from 66.2 % to 105.6 %. This variation in efficiency occurs when the compressor outlet pressure is optimized within the range from 5 MPa to 8 MPa. The system levelized cost of storage declines as geothermal temperature rises and its minimum value is 0.472 CNY/kWh when the geothermal temperature is 90 °C.</div></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":"329 ","pages":"Article 119660"},"PeriodicalIF":9.9000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0196890425001839","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Unstable renewable energy sources, including wind and photovoltaic power generation with the inherent characteristics of intermittency and randomness, pose an extremely significant challenges to the safety and stability of electrical grids. Considered a viable solution, energy storage technology increases the flexibility and regulatory capacity of power grids by storing and releasing excess electricity at different times. Pump thermal energy storage technology offers an efficient large-scale electricity storage solution that is completely free from geographical location limitations. Skillfully integrating pumped thermal energy storage technology with low-grade heat can effectively improve its thermodynamic and economic performance. To significantly enhance the utilization rate of geothermal energy and effectively achieve a more optimal performance of pumped thermal energy storage systems, the in-depth and comprehensive study conducted a thermo-economic evaluation of 15 types of geothermal-assisted transcritical pumped thermal energy storage systems. This study provides configuration selection maps for the round trip efficiency and the levelized cost of storage, thereby enabling an extremely effective and swift evaluation of the performance of these various configuration systems. When the geothermal temperature changes within the range from 50 °C to 90 °C, the efficiency of the systems that are considered to be the most suitable under these conditions varies from 66.2 % to 105.6 %. This variation in efficiency occurs when the compressor outlet pressure is optimized within the range from 5 MPa to 8 MPa. The system levelized cost of storage declines as geothermal temperature rises and its minimum value is 0.472 CNY/kWh when the geothermal temperature is 90 °C.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy Conversion and Management
Energy Conversion and Management 工程技术-力学
CiteScore
19.00
自引率
11.50%
发文量
1304
审稿时长
17 days
期刊介绍: The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics. The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信