First experiences with multiple bilateral insertions of a newly developed microcatheter-compatible endovascular electroencephalogram electrode for humans with epilepsy

IF 1.8 Q3 CLINICAL NEUROLOGY
Yosuke Masuda , Ayataka Fujimoto , Hisayuki Hosoo , Kota Araki , Hiroki Ishida , Mitsuyo Nishimura , Aiki Marushima , Eiichi Ishikawa , Yuji Matsumaru
{"title":"First experiences with multiple bilateral insertions of a newly developed microcatheter-compatible endovascular electroencephalogram electrode for humans with epilepsy","authors":"Yosuke Masuda ,&nbsp;Ayataka Fujimoto ,&nbsp;Hisayuki Hosoo ,&nbsp;Kota Araki ,&nbsp;Hiroki Ishida ,&nbsp;Mitsuyo Nishimura ,&nbsp;Aiki Marushima ,&nbsp;Eiichi Ishikawa ,&nbsp;Yuji Matsumaru","doi":"10.1016/j.ebr.2025.100748","DOIUrl":null,"url":null,"abstract":"<div><div>Identifying epileptogenic zones non-invasively is challenging due to signal interference by the scalp and skull, necessitating invasive methods like subdural recordings and stereoelectroencephalography. Recent microcatheter advancements suggest that a microcatheter-compatible endovascular EEG (eEEG) device could overcome these barriers. We developed a thin, flexible eEEG electrode, the EP-01, for use with current microcatheters. The EP-01, comprising a platinum electrode and alloy wire coated with an electrically non-conductive polymer, was inserted via the jugular veins under local anesthesia. The EP-01 electrodes were planned to be placed in six locations: bilateral transverse sinuses, bilateral cavernous sinuses, and the anterior and posterior superior sagittal sinuses. We conducted a first-in-human study demonstrating the feasibility and efficacy of the EP-01electrodes in simultaneously recording intracranial EEG signals from multiple brain locations. The EP-01 electrodes were successfully placed as planned, except for one, without complications. Simultaneous eEEG and scalp EEG recordings were performed during a Wada test to evaluate efficacy and safety. The eEEG recorded alpha waves and slow-wave activity during propofol administration, corresponding to scalp EEG findings, with amplitudes 3–4 times higher. Post-procedural assessments confirmed cranial vessels’ patency and absence of complications. The EP-01 successfully recorded EEG signals at multiple locations in the human brain using an endovascular approach. Compared to scalp EEG, the present approach seems to have the potential to record higher-amplitude EEG. However, the study was limited to short-term recordings without epileptic discharges. Further investigations, including long-term placement, are thus needed for seizure recordings and safety evaluations.</div></div>","PeriodicalId":36558,"journal":{"name":"Epilepsy and Behavior Reports","volume":"29 ","pages":"Article 100748"},"PeriodicalIF":1.8000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Epilepsy and Behavior Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589986425000085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Identifying epileptogenic zones non-invasively is challenging due to signal interference by the scalp and skull, necessitating invasive methods like subdural recordings and stereoelectroencephalography. Recent microcatheter advancements suggest that a microcatheter-compatible endovascular EEG (eEEG) device could overcome these barriers. We developed a thin, flexible eEEG electrode, the EP-01, for use with current microcatheters. The EP-01, comprising a platinum electrode and alloy wire coated with an electrically non-conductive polymer, was inserted via the jugular veins under local anesthesia. The EP-01 electrodes were planned to be placed in six locations: bilateral transverse sinuses, bilateral cavernous sinuses, and the anterior and posterior superior sagittal sinuses. We conducted a first-in-human study demonstrating the feasibility and efficacy of the EP-01electrodes in simultaneously recording intracranial EEG signals from multiple brain locations. The EP-01 electrodes were successfully placed as planned, except for one, without complications. Simultaneous eEEG and scalp EEG recordings were performed during a Wada test to evaluate efficacy and safety. The eEEG recorded alpha waves and slow-wave activity during propofol administration, corresponding to scalp EEG findings, with amplitudes 3–4 times higher. Post-procedural assessments confirmed cranial vessels’ patency and absence of complications. The EP-01 successfully recorded EEG signals at multiple locations in the human brain using an endovascular approach. Compared to scalp EEG, the present approach seems to have the potential to record higher-amplitude EEG. However, the study was limited to short-term recordings without epileptic discharges. Further investigations, including long-term placement, are thus needed for seizure recordings and safety evaluations.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Epilepsy and Behavior Reports
Epilepsy and Behavior Reports Medicine-Neurology (clinical)
CiteScore
2.70
自引率
13.30%
发文量
54
审稿时长
50 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信