Torsional behavior of peripheral vascular stents: The role of stent design parameters.

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Xiang Shen, Jiahao Chen, Yue Xu, Qiang Liu, Zewen He, Lei Wang, Peng Sun, Hongfei Zhu, Hengfeng Yan
{"title":"Torsional behavior of peripheral vascular stents: The role of stent design parameters.","authors":"Xiang Shen, Jiahao Chen, Yue Xu, Qiang Liu, Zewen He, Lei Wang, Peng Sun, Hongfei Zhu, Hengfeng Yan","doi":"10.1177/09544119251317621","DOIUrl":null,"url":null,"abstract":"<p><p>Torsional performance is a critical evaluation criterion in the design of peripheral vascular stents, enabling them to adapt to the deformation of the vessel to reduce damage to the vascular wall and thus avoiding in-stent restenosis (ISR). Therefore, this study employed the finite element method (FEM) to investigate the impact of stent design parameters on the torsional behavior of self-expanding peripheral vascular stents. These parameters included stent diameter and thickness, as well as the length and width of struts and links. Results revealed that among all parameters, strut length and width significantly influence the stent torsional performance, whereas link width has a lesser effect. Notably, increasing strut length and decreasing strut width were found to significantly reduce the required torque, with the twist metric (TM) reduced by approximately 86.3% when strut length increased from 1.2 to 2.8 mm. Moreover, reductions in stent diameter and thickness, alongside an increase in link length, further contributed to a decrease in TM, thereby enhancing the stent torsional performance. This study may provide insights for better peripheral stent design and clinical decision of stent choice.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"9544119251317621"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119251317621","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Torsional performance is a critical evaluation criterion in the design of peripheral vascular stents, enabling them to adapt to the deformation of the vessel to reduce damage to the vascular wall and thus avoiding in-stent restenosis (ISR). Therefore, this study employed the finite element method (FEM) to investigate the impact of stent design parameters on the torsional behavior of self-expanding peripheral vascular stents. These parameters included stent diameter and thickness, as well as the length and width of struts and links. Results revealed that among all parameters, strut length and width significantly influence the stent torsional performance, whereas link width has a lesser effect. Notably, increasing strut length and decreasing strut width were found to significantly reduce the required torque, with the twist metric (TM) reduced by approximately 86.3% when strut length increased from 1.2 to 2.8 mm. Moreover, reductions in stent diameter and thickness, alongside an increase in link length, further contributed to a decrease in TM, thereby enhancing the stent torsional performance. This study may provide insights for better peripheral stent design and clinical decision of stent choice.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信