Development and validation of an automated Trunk Impairment Scale 2.0 scoring system using rule-based classification.

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Tay Jia Yi, Zaidi Mohd Ripin, Mohamad Ikhwan Zaini Ridzwan, Muhammad Fauzinizam Razali, Yeo Ying Heng, Nur Akasyah Binti Jaafar, Alexander Tan Wai Teng, Hazwani Binti Ahmad Yusof, Muhammad Hafiz Hanafi
{"title":"Development and validation of an automated Trunk Impairment Scale 2.0 scoring system using rule-based classification.","authors":"Tay Jia Yi, Zaidi Mohd Ripin, Mohamad Ikhwan Zaini Ridzwan, Muhammad Fauzinizam Razali, Yeo Ying Heng, Nur Akasyah Binti Jaafar, Alexander Tan Wai Teng, Hazwani Binti Ahmad Yusof, Muhammad Hafiz Hanafi","doi":"10.1177/09544119251317614","DOIUrl":null,"url":null,"abstract":"<p><p>The Trunk Impairment Scale Version 2.0 (TIS 2.0) measures the motor impairment of the trunk after a stroke through the evaluation of dynamic sitting balance and co-ordination of trunk movement. Evaluations by physiotherapists depend on their ability in detecting minor changes in motion and observing limb movements and these can be time consuming and reduce their availability for rehabilitation work. An automated scoring system for TIS 2.0 was proposed to provide a more reproducible and standardized alternative to manual physiotherapist assessments. In the development phase, motion data from lay actors simulating stroke condition were collected using video motion capture system OpenCap. This data was utilized to create metrics and establish cut-off values for a rule-based classification. The discriminant abilities of the metrics were evaluated using the area under the curve (AUC). In the testing phase, the performance of the developed system was assessed on 19 stroke survivors (Berg Balance Scale score of 20-55) using both automated system and manual scoring by nine physiotherapists. The discriminant abilities of the features used in the dynamic sitting balance subscale are considered excellent to outstanding (AUC ≥ 0.717), and coordination subscale ranged from poor to outstanding (AUC ≥ 0.667). The automated scores aligned with physiotherapists' scores, achieving an average percentage of agreement 71.1%. The total TIS 2.0 scores generated by the automated method showed moderate correlation with the sum of mode-determined task scores (<i>R</i> = 0.526, <i>p</i> < 0.05). These findings suggest that the proposed automated system demonstrates comparable validity to assessments by physiotherapists.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"9544119251317614"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119251317614","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The Trunk Impairment Scale Version 2.0 (TIS 2.0) measures the motor impairment of the trunk after a stroke through the evaluation of dynamic sitting balance and co-ordination of trunk movement. Evaluations by physiotherapists depend on their ability in detecting minor changes in motion and observing limb movements and these can be time consuming and reduce their availability for rehabilitation work. An automated scoring system for TIS 2.0 was proposed to provide a more reproducible and standardized alternative to manual physiotherapist assessments. In the development phase, motion data from lay actors simulating stroke condition were collected using video motion capture system OpenCap. This data was utilized to create metrics and establish cut-off values for a rule-based classification. The discriminant abilities of the metrics were evaluated using the area under the curve (AUC). In the testing phase, the performance of the developed system was assessed on 19 stroke survivors (Berg Balance Scale score of 20-55) using both automated system and manual scoring by nine physiotherapists. The discriminant abilities of the features used in the dynamic sitting balance subscale are considered excellent to outstanding (AUC ≥ 0.717), and coordination subscale ranged from poor to outstanding (AUC ≥ 0.667). The automated scores aligned with physiotherapists' scores, achieving an average percentage of agreement 71.1%. The total TIS 2.0 scores generated by the automated method showed moderate correlation with the sum of mode-determined task scores (R = 0.526, p < 0.05). These findings suggest that the proposed automated system demonstrates comparable validity to assessments by physiotherapists.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信