A novel minimally invasive technique for the treatment of tibial plateau collapse fracture: radiological and arthroscopic evaluation.

IF 2 3区 医学 Q2 ORTHOPEDICS
International Orthopaedics Pub Date : 2025-05-01 Epub Date: 2025-02-17 DOI:10.1007/s00264-025-06405-7
Wei He, Fengkun Wang, Guimiao Li, Shuai Yang, Chengsi Li, Zhongzheng Wang, Wen An, Chunxu Fu, Yanjiang Yang, Yanbin Zhu, Yingze Zhang
{"title":"A novel minimally invasive technique for the treatment of tibial plateau collapse fracture: radiological and arthroscopic evaluation.","authors":"Wei He, Fengkun Wang, Guimiao Li, Shuai Yang, Chengsi Li, Zhongzheng Wang, Wen An, Chunxu Fu, Yanjiang Yang, Yanbin Zhu, Yingze Zhang","doi":"10.1007/s00264-025-06405-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine the effectiveness of a novel bone graft reduction technique with a bone tamp impactor instrument in minimally invasive treatment of tibial plateau collapse fractures through arthroscopic and imaging evaluation.</p><p><strong>Methods: </strong>This is a retrospective analysis of prospectively collected data on patients with tibial plateau collapse fracture who received the novel bone graft reduction procedure with a bone tamp impactor instrument for minimally invasive treatment of tibial plateau collapse fractures in a tertiary referral university hospital from February 2021 to March 2023. Patients were classified according to a classification combined with Schatzker classification, AO classification and three-column classification. Arthroscopy evaluation and radiographs were used to measure the reduction effect.</p><p><strong>Results: </strong>A total of 196 patients were eligible and included. Compared to the preoperative values, post-ADD(c) showed a significant reduction improvement (P = 0.000-0.007), ranging from 87.9 to 96.6% for different classifications. The post-ADD (s) have decreased by 87-96.8% (P = 0.000-0.039), the post-FFG and post-TPW reduced by 87.5-100% (P = 0.000-0.026) and 34.2-63.5% (P = 0.000-0.075) respectively. Additionally, the lower limb alignment have been significantly corrected, with notable changes in post-MPTA (P = 0.000-0.081), post-PTSA (P = 0.000-0.178) and post-FTA (P = 0.000-0.069) for different types of fracture, measured one day after surgery. Arthroscopic evaluation indicated that the average articular surface depression depth was less than 4 mm, and over 60% achieved a depression depth of less than 2 mm. All patient achieved a less than 2 mm of postoperative fracture fragment gap, with over 50% achieving a gap of less than 1 mm. None of patients experienced neurovascular injury or wound infection.</p><p><strong>Conclusion: </strong>The novel bone graft reduction technique utilizing a bone tamp impactor instrument can achieve effective reduction in all types of tibial plateau collapse fractures. This method may prove to be a useful option for minimally invasive treatment of tibial plateau fractures.</p>","PeriodicalId":14450,"journal":{"name":"International Orthopaedics","volume":" ","pages":"1235-1243"},"PeriodicalIF":2.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-025-06405-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/17 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To examine the effectiveness of a novel bone graft reduction technique with a bone tamp impactor instrument in minimally invasive treatment of tibial plateau collapse fractures through arthroscopic and imaging evaluation.

Methods: This is a retrospective analysis of prospectively collected data on patients with tibial plateau collapse fracture who received the novel bone graft reduction procedure with a bone tamp impactor instrument for minimally invasive treatment of tibial plateau collapse fractures in a tertiary referral university hospital from February 2021 to March 2023. Patients were classified according to a classification combined with Schatzker classification, AO classification and three-column classification. Arthroscopy evaluation and radiographs were used to measure the reduction effect.

Results: A total of 196 patients were eligible and included. Compared to the preoperative values, post-ADD(c) showed a significant reduction improvement (P = 0.000-0.007), ranging from 87.9 to 96.6% for different classifications. The post-ADD (s) have decreased by 87-96.8% (P = 0.000-0.039), the post-FFG and post-TPW reduced by 87.5-100% (P = 0.000-0.026) and 34.2-63.5% (P = 0.000-0.075) respectively. Additionally, the lower limb alignment have been significantly corrected, with notable changes in post-MPTA (P = 0.000-0.081), post-PTSA (P = 0.000-0.178) and post-FTA (P = 0.000-0.069) for different types of fracture, measured one day after surgery. Arthroscopic evaluation indicated that the average articular surface depression depth was less than 4 mm, and over 60% achieved a depression depth of less than 2 mm. All patient achieved a less than 2 mm of postoperative fracture fragment gap, with over 50% achieving a gap of less than 1 mm. None of patients experienced neurovascular injury or wound infection.

Conclusion: The novel bone graft reduction technique utilizing a bone tamp impactor instrument can achieve effective reduction in all types of tibial plateau collapse fractures. This method may prove to be a useful option for minimally invasive treatment of tibial plateau fractures.

一种治疗胫骨平台塌陷骨折的新型微创技术:放射学和关节镜评估。
目的:通过关节镜及影像学评价,探讨一种新型骨瓣复位技术在胫骨平台塌陷骨折微创治疗中的应用效果。方法:回顾性分析2021年2月至2023年3月在某三级转诊大学医院接受骨夯冲击器微创治疗胫骨平台塌陷骨折的新型植骨复位手术患者的前瞻性数据。采用Schatzker分型、AO分型和三柱分型相结合的分型对患者进行分类。关节镜评估和x线片测量复位效果。结果:共纳入196例患者。与术前相比,add后(c)表现出显著的降低改善(P = 0.000-0.007),不同分类的改善范围为87.9 - 96.6%。add (s)后降低了87 ~ 96.8% (P = 0.000 ~ 0.039), ffg和tpw分别降低了87.5 ~ 100% (P = 0.000 ~ 0.026)和342 ~ 63.5% (P = 0.000 ~ 0.075)。此外,下肢对线得到了明显的纠正,不同类型骨折术后1天测量的mpta后(P = 0.000-0.081)、ptsa后(P = 0.000-0.178)和fta后(P = 0.000-0.069)的变化显著。关节镜评估显示平均关节面凹陷深度小于4 mm,超过60%的关节面凹陷深度小于2 mm。所有患者术后骨折碎片间隙均小于2mm,超过50%的患者术后骨折碎片间隙小于1mm。所有患者均无神经血管损伤或伤口感染。结论:采用骨压冲击器的新型植骨复位技术可有效复位各种类型的胫骨平台塌陷骨折。这种方法可能被证明是胫骨平台骨折微创治疗的一个有用的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Orthopaedics
International Orthopaedics 医学-整形外科
CiteScore
5.50
自引率
7.40%
发文量
360
审稿时长
1 months
期刊介绍: International Orthopaedics, the Official Journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT) , publishes original papers from all over the world. The articles deal with clinical orthopaedic surgery or basic research directly connected with orthopaedic surgery. International Orthopaedics will also link all the members of SICOT by means of an insert that will be concerned with SICOT matters. Finally, it is expected that news and information regarding all aspects of orthopaedic surgery, including meetings, panels, instructional courses, etc. will be brought to the attention of the readers. Manuscripts submitted for publication must contain a statement to the effect that all human studies have been approved by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted. Reports of animal experiments must state that the "Principles of laboratory animal care" (NIH publication No. 85-23, revised 1985) were followed, as well as specific national laws (e.g. the current version of the German Law on the Protection of Animals) where applicable. The editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfil the above-mentioned requirements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信