Multi-modal transport of intensity diffraction tomography microscopy with an electrically tunable lens [Invited].

IF 2.9 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Biomedical optics express Pub Date : 2025-01-31 eCollection Date: 2025-02-01 DOI:10.1364/BOE.545258
Zihao Zhou, Runnan Zhang, Ning Zhou, Qian Chen, Chao Zuo
{"title":"Multi-modal transport of intensity diffraction tomography microscopy with an electrically tunable lens [Invited].","authors":"Zihao Zhou, Runnan Zhang, Ning Zhou, Qian Chen, Chao Zuo","doi":"10.1364/BOE.545258","DOIUrl":null,"url":null,"abstract":"<p><p>Optical diffraction tomography (ODT) is an important technique for three-dimensional (3D) imaging of semi-transparent biological samples, enabling volumetric visualization of living cells, cultures, and tissues without the need for exogenous dyes. However, ODT faces significant challenges in imaging complex biological specimens due to the limited specificity of refractive index (RI) and the coupled relationship between absorption and phase in image formation. Here, we present multi-modal transport of intensity diffraction tomography (MM-TIDT), a high-speed 3D microscopy technique that integrates an electrically tunable lens with modified illumination patterns to decouple phase and absorption information. Leveraging dual illumination schemes-circular and annular apertures-MM-TIDT acquires two intensity stacks, facilitating accurate phase and absorption decoupling. Based on an alternating direction method of multipliers (ADMM) framework with total variation (TV) and non-negativity regularization, our method reconstructs multi-modal 3D distributions of fluorescence and complex RI with high accuracy and robustness. Experimental validation with fluorescent polystyrene microspheres, Spirulina specimens, and DAPI-labeled C166 cells demonstrates the multi-modal imaging capability of MM-TIDT to resolve fine structural details across diverse sample types, providing a versatile platform for exploring dynamic biological processes and intricate cellular interactions.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"16 2","pages":"837-848"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11828454/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.545258","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Optical diffraction tomography (ODT) is an important technique for three-dimensional (3D) imaging of semi-transparent biological samples, enabling volumetric visualization of living cells, cultures, and tissues without the need for exogenous dyes. However, ODT faces significant challenges in imaging complex biological specimens due to the limited specificity of refractive index (RI) and the coupled relationship between absorption and phase in image formation. Here, we present multi-modal transport of intensity diffraction tomography (MM-TIDT), a high-speed 3D microscopy technique that integrates an electrically tunable lens with modified illumination patterns to decouple phase and absorption information. Leveraging dual illumination schemes-circular and annular apertures-MM-TIDT acquires two intensity stacks, facilitating accurate phase and absorption decoupling. Based on an alternating direction method of multipliers (ADMM) framework with total variation (TV) and non-negativity regularization, our method reconstructs multi-modal 3D distributions of fluorescence and complex RI with high accuracy and robustness. Experimental validation with fluorescent polystyrene microspheres, Spirulina specimens, and DAPI-labeled C166 cells demonstrates the multi-modal imaging capability of MM-TIDT to resolve fine structural details across diverse sample types, providing a versatile platform for exploring dynamic biological processes and intricate cellular interactions.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信