Antonio J Del Águila-Carrasco, Aixa Alarcon, Henk Weeber, Linda Tsai, Srividhya Vilupuru, Carmen Canovas, Patricia Piers
{"title":"Prediction of monocular defocus curves in pseudophakia with different pupil sizes.","authors":"Antonio J Del Águila-Carrasco, Aixa Alarcon, Henk Weeber, Linda Tsai, Srividhya Vilupuru, Carmen Canovas, Patricia Piers","doi":"10.1364/BOE.540583","DOIUrl":null,"url":null,"abstract":"<p><p>Existing models for predicting clinical visual acuity (VA) following lens replacement surgery use controlled experimental conditions where pupil size is typically fixed. However, pupil size may influence visual performance depending on the design of the intraocular lens (IOL) implanted. This study compares optical bench testing metrics to clinical VA in pseudophakic patients with different pupil sizes and IOL models. The area under the modulation transfer function (MTFa) and the weighted optical transfer function (wOTF) were obtained at vergences ranging from -3 D to 0.5 D, and different pupil sizes: 2, 3, and 4.5 mm. The simulated VA values obtained for both metrics were well correlated with clinical data (R<sup>2</sup> ≥ 0.85) and had low root mean square errors (RMSe) for the entire defocus range, suggesting their suitability for predicting VA defocus curves in pseudophakic eyes with varying pupil size.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"16 2","pages":"709-717"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11828456/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.540583","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Existing models for predicting clinical visual acuity (VA) following lens replacement surgery use controlled experimental conditions where pupil size is typically fixed. However, pupil size may influence visual performance depending on the design of the intraocular lens (IOL) implanted. This study compares optical bench testing metrics to clinical VA in pseudophakic patients with different pupil sizes and IOL models. The area under the modulation transfer function (MTFa) and the weighted optical transfer function (wOTF) were obtained at vergences ranging from -3 D to 0.5 D, and different pupil sizes: 2, 3, and 4.5 mm. The simulated VA values obtained for both metrics were well correlated with clinical data (R2 ≥ 0.85) and had low root mean square errors (RMSe) for the entire defocus range, suggesting their suitability for predicting VA defocus curves in pseudophakic eyes with varying pupil size.
期刊介绍:
The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including:
Tissue optics and spectroscopy
Novel microscopies
Optical coherence tomography
Diffuse and fluorescence tomography
Photoacoustic and multimodal imaging
Molecular imaging and therapies
Nanophotonic biosensing
Optical biophysics/photobiology
Microfluidic optical devices
Vision research.