Highly Sensitive Measurement of AC Loss Characteristics of Short and Straight HTS Tapes Under Transverse Magnetic Field by Pickup Coil Method

IF 1.7 3区 物理与天体物理 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Shuma Kawabata;Tadashi Hirayama
{"title":"Highly Sensitive Measurement of AC Loss Characteristics of Short and Straight HTS Tapes Under Transverse Magnetic Field by Pickup Coil Method","authors":"Shuma Kawabata;Tadashi Hirayama","doi":"10.1109/TASC.2025.3535851","DOIUrl":null,"url":null,"abstract":"In order to develop high temperature superconducting (HTS) tapes with excellent low-loss characteristics, it is indispensable to have a measurement system capable of measuring the AC loss characteristics of HTS tapes with high sensitivity at 77 K. We have developed a measurement system using the pickup coil method, which can measure the AC loss characteristics of short straight HTS tapes under AC transverse magnetic fields with high sensitivity. In the pickup coil method, pickup coils consist of a main pickup coil for measuring the specimen signal voltage and a compensation coil used to extract only the magnetization signal voltage of the specimen contained in the main pickup coil voltage. In order to increase the sensitivity of AC loss measurement systems using the pickup coil method, background losses, which are apparent losses that occur even when there is no sample in the main pickup coil, must be reduced as much as possible. To reduce background losses, first, a magnet was designed and manufactured to apply external transverse magnetic fields so that a main pickup coil and a compensation coil could be arranged symmetrically. This makes it possible to reduce the phase difference between the main pickup coil voltage and the compensation coil voltage, which is one of the main causes of background losses. Next, background losses were measured using several kinds of pickup coils with different parameters. Furthermore, based on the measurement results, the optimum parameters of the pickup coils were investigated. Finally, background losses could be successfully reduced, and the sensitivity of the AC loss measurement system increased.","PeriodicalId":13104,"journal":{"name":"IEEE Transactions on Applied Superconductivity","volume":"35 5","pages":"1-4"},"PeriodicalIF":1.7000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Applied Superconductivity","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/10857462/","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

In order to develop high temperature superconducting (HTS) tapes with excellent low-loss characteristics, it is indispensable to have a measurement system capable of measuring the AC loss characteristics of HTS tapes with high sensitivity at 77 K. We have developed a measurement system using the pickup coil method, which can measure the AC loss characteristics of short straight HTS tapes under AC transverse magnetic fields with high sensitivity. In the pickup coil method, pickup coils consist of a main pickup coil for measuring the specimen signal voltage and a compensation coil used to extract only the magnetization signal voltage of the specimen contained in the main pickup coil voltage. In order to increase the sensitivity of AC loss measurement systems using the pickup coil method, background losses, which are apparent losses that occur even when there is no sample in the main pickup coil, must be reduced as much as possible. To reduce background losses, first, a magnet was designed and manufactured to apply external transverse magnetic fields so that a main pickup coil and a compensation coil could be arranged symmetrically. This makes it possible to reduce the phase difference between the main pickup coil voltage and the compensation coil voltage, which is one of the main causes of background losses. Next, background losses were measured using several kinds of pickup coils with different parameters. Furthermore, based on the measurement results, the optimum parameters of the pickup coils were investigated. Finally, background losses could be successfully reduced, and the sensitivity of the AC loss measurement system increased.
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Applied Superconductivity
IEEE Transactions on Applied Superconductivity 工程技术-工程:电子与电气
CiteScore
3.50
自引率
33.30%
发文量
650
审稿时长
2.3 months
期刊介绍: IEEE Transactions on Applied Superconductivity (TAS) contains articles on the applications of superconductivity and other relevant technology. Electronic applications include analog and digital circuits employing thin films and active devices such as Josephson junctions. Large scale applications include magnets for power applications such as motors and generators, for magnetic resonance, for accelerators, and cable applications such as power transmission.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信