Modelling COVID-19 epidemic curve in Taipei City, Taiwan by a citywide wastewater SARS-CoV-2 Surveillance

IF 5.4 Q2 ENGINEERING, ENVIRONMENTAL
Chung-Yen Chen , Yu-Hsiang Chang , Chi-Hsin Sally Chen , Sui-Yuan Chang , Chang-Chuan Chan , Pau-Chung Chen , Ta-Chen Su
{"title":"Modelling COVID-19 epidemic curve in Taipei City, Taiwan by a citywide wastewater SARS-CoV-2 Surveillance","authors":"Chung-Yen Chen ,&nbsp;Yu-Hsiang Chang ,&nbsp;Chi-Hsin Sally Chen ,&nbsp;Sui-Yuan Chang ,&nbsp;Chang-Chuan Chan ,&nbsp;Pau-Chung Chen ,&nbsp;Ta-Chen Su","doi":"10.1016/j.hazadv.2025.100635","DOIUrl":null,"url":null,"abstract":"<div><div>Over 70 countries have adopted wastewater surveillance during the COVID-19 pandemic as a novel tool to detect unidentified cases and monitor epidemic curves. However, epidemic prediction models are highly site-specific, necessitating tailored approaches. This study aimed to establish a citywide wastewater surveillance system and develop an epidemic prediction model for Taipei City, Taiwan. From May to August 2022, wastewater samples were collected daily from the Xinyi and Neihu districts and twice weekly from the remaining 10 districts. SARS-CoV-2 genetic material was quantified using RT-qPCR, and a “relative signal” was calculated as the ratio of SARS-CoV-2 viral concentration to the concentration of the human RNase P gene to normalize variability in sample collection. Regression analysis based on data from the two districts was conducted to forecast new COVID-19 cases. On average, wastewater samples contained 1,829.0 ± 2,237.7 viral copies per liter, with relative signals averaging 17.1 ± 16.7. The best-fitting model, adjusted for temperature, indicated that a 1 % increase in viral signals corresponded to an approximately 0.27 % rise in the future 5-day moving average of new cases. With an R-squared value of 0.78, the model demonstrated robust explanatory power. The model, validated via a paired sample <em>t</em>-test, reliably estimated epidemic trends with no significant difference between predicted and reported cases in the other 10 districts. These findings suggest that wastewater viral surveillance can be an effective supplementary tool for epidemic forecasting in urban settings like Taipei, where high sewer connectivity is in place.</div></div>","PeriodicalId":73763,"journal":{"name":"Journal of hazardous materials advances","volume":"18 ","pages":"Article 100635"},"PeriodicalIF":5.4000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of hazardous materials advances","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772416625000476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Over 70 countries have adopted wastewater surveillance during the COVID-19 pandemic as a novel tool to detect unidentified cases and monitor epidemic curves. However, epidemic prediction models are highly site-specific, necessitating tailored approaches. This study aimed to establish a citywide wastewater surveillance system and develop an epidemic prediction model for Taipei City, Taiwan. From May to August 2022, wastewater samples were collected daily from the Xinyi and Neihu districts and twice weekly from the remaining 10 districts. SARS-CoV-2 genetic material was quantified using RT-qPCR, and a “relative signal” was calculated as the ratio of SARS-CoV-2 viral concentration to the concentration of the human RNase P gene to normalize variability in sample collection. Regression analysis based on data from the two districts was conducted to forecast new COVID-19 cases. On average, wastewater samples contained 1,829.0 ± 2,237.7 viral copies per liter, with relative signals averaging 17.1 ± 16.7. The best-fitting model, adjusted for temperature, indicated that a 1 % increase in viral signals corresponded to an approximately 0.27 % rise in the future 5-day moving average of new cases. With an R-squared value of 0.78, the model demonstrated robust explanatory power. The model, validated via a paired sample t-test, reliably estimated epidemic trends with no significant difference between predicted and reported cases in the other 10 districts. These findings suggest that wastewater viral surveillance can be an effective supplementary tool for epidemic forecasting in urban settings like Taipei, where high sewer connectivity is in place.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of hazardous materials advances
Journal of hazardous materials advances Environmental Engineering
CiteScore
4.80
自引率
0.00%
发文量
0
审稿时长
50 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信