Preclinical evaluation of a hydraulic actuation system with guide tube for robotic cochlear implant electrode insertion.

IF 2.9 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Jakob Cramer, Rolf Salcher, Max Fröhlich, Georg Böttcher-Rebmann, Eralp Artukarslan, Thomas Lenarz, Thomas S Rau
{"title":"Preclinical evaluation of a hydraulic actuation system with guide tube for robotic cochlear implant electrode insertion.","authors":"Jakob Cramer, Rolf Salcher, Max Fröhlich, Georg Böttcher-Rebmann, Eralp Artukarslan, Thomas Lenarz, Thomas S Rau","doi":"10.1186/s12938-025-01338-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Automated insertion of the cochlear implant electrode array can reduce the risk of intracochlear trauma. To address this, our group previously developed a hydraulic electrode insertion device, the Cochlea Hydrodrive (CHD), which automates the process using a syringe piston driven by an infusion pump. This study aims to characterize the hydraulic actuation process of the CHD and to preclinically evaluate its design.</p><p><strong>Methods: </strong>A camera-based motion tracking test setup was developed to obtain hydraulic motion profiles. Various syringes were evaluated for their actuation properties and the optimal syringe was selected. The CHD design was adapted based on the selected syringe, incorporating a slotted stainless steel guide tube to surround the electrode during insertion. This enhanced design was tested in ex vivo insertion trials into human head specimens.</p><p><strong>Results: </strong>The final design of the CHD demonstrated smooth and steady motion profiles at all tested velocities (0.4 mm/s, 0.1 mm/s, 0.03 mm/s). Ex vivo insertion trials confirmed these findings, with the guide tube facilitating easy alignment of the CHD in front of the round window and preventing electrode buckling.</p><p><strong>Conclusion: </strong>Our study validates that the CHD provides reliably smooth actuation properties despite its low complexity. The use of a guide tube appears promising and could further enhance the standardization of automated electrode insertion.</p>","PeriodicalId":8927,"journal":{"name":"BioMedical Engineering OnLine","volume":"24 1","pages":"19"},"PeriodicalIF":2.9000,"publicationDate":"2025-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11829445/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioMedical Engineering OnLine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1186/s12938-025-01338-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Automated insertion of the cochlear implant electrode array can reduce the risk of intracochlear trauma. To address this, our group previously developed a hydraulic electrode insertion device, the Cochlea Hydrodrive (CHD), which automates the process using a syringe piston driven by an infusion pump. This study aims to characterize the hydraulic actuation process of the CHD and to preclinically evaluate its design.

Methods: A camera-based motion tracking test setup was developed to obtain hydraulic motion profiles. Various syringes were evaluated for their actuation properties and the optimal syringe was selected. The CHD design was adapted based on the selected syringe, incorporating a slotted stainless steel guide tube to surround the electrode during insertion. This enhanced design was tested in ex vivo insertion trials into human head specimens.

Results: The final design of the CHD demonstrated smooth and steady motion profiles at all tested velocities (0.4 mm/s, 0.1 mm/s, 0.03 mm/s). Ex vivo insertion trials confirmed these findings, with the guide tube facilitating easy alignment of the CHD in front of the round window and preventing electrode buckling.

Conclusion: Our study validates that the CHD provides reliably smooth actuation properties despite its low complexity. The use of a guide tube appears promising and could further enhance the standardization of automated electrode insertion.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BioMedical Engineering OnLine
BioMedical Engineering OnLine 工程技术-工程:生物医学
CiteScore
6.70
自引率
2.60%
发文量
79
审稿时长
1 months
期刊介绍: BioMedical Engineering OnLine is an open access, peer-reviewed journal that is dedicated to publishing research in all areas of biomedical engineering. BioMedical Engineering OnLine is aimed at readers and authors throughout the world, with an interest in using tools of the physical and data sciences and techniques in engineering to understand and solve problems in the biological and medical sciences. Topical areas include, but are not limited to: Bioinformatics- Bioinstrumentation- Biomechanics- Biomedical Devices & Instrumentation- Biomedical Signal Processing- Healthcare Information Systems- Human Dynamics- Neural Engineering- Rehabilitation Engineering- Biomaterials- Biomedical Imaging & Image Processing- BioMEMS and On-Chip Devices- Bio-Micro/Nano Technologies- Biomolecular Engineering- Biosensors- Cardiovascular Systems Engineering- Cellular Engineering- Clinical Engineering- Computational Biology- Drug Delivery Technologies- Modeling Methodologies- Nanomaterials and Nanotechnology in Biomedicine- Respiratory Systems Engineering- Robotics in Medicine- Systems and Synthetic Biology- Systems Biology- Telemedicine/Smartphone Applications in Medicine- Therapeutic Systems, Devices and Technologies- Tissue Engineering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信