Jon R Sobus, Nickolas A Sayre-Smith, Alex Chao, Troy M Ferland, Jeffrey M Minucci, E Tyler Carr, Laura D Brunelle, Angela L Batt, Heather D Whitehead, Tommy Cathey, Matthew Boyce, Elin M Ulrich, James P McCord, Antony J Williams
{"title":"Automated QA/QC reporting for non-targeted analysis: a demonstration of \"INTERPRET NTA\" with de facto water reuse data.","authors":"Jon R Sobus, Nickolas A Sayre-Smith, Alex Chao, Troy M Ferland, Jeffrey M Minucci, E Tyler Carr, Laura D Brunelle, Angela L Batt, Heather D Whitehead, Tommy Cathey, Matthew Boyce, Elin M Ulrich, James P McCord, Antony J Williams","doi":"10.1007/s00216-025-05771-w","DOIUrl":null,"url":null,"abstract":"<p><p>The US Environmental Protection Agency (EPA) uses non-targeted analysis (NTA) to characterize potential risks associated with environmental pollutants and anthropogenic materials. NTA is used throughout EPA's Office of Research and Development (ORD) to support the needs of states, tribes, EPA regions, EPA program offices, and other outside partners. NTA methods are complex and conducted via myriad instrumental platforms and software products. Comprehensive standards do not yet exist to guide NTA quality assurance/quality control (QA/QC) procedures. Furthermore, no single software tool meets EPA's needs for QA/QC review and documentation. Considering these factors, ORD developed \"INTERPRET NTA\" (Interface for Processing, Reviewing, and Translating NTA data) to support liquid chromatography (LC) high-resolution mass spectrometry (HRMS) NTA experiments. For purposes of NTA QA/QC, INTERPRET NTA (1) calculates data quality statistics related to accuracy, precision, and reproducibility; (2) produces interactive visualizations to facilitate quality threshold optimization; and (3) outputs comprehensive documentation for inclusion in official reports and research publications. INTERPRET NTA has additional functionality to facilitate rapid chemical identification and risk-based prioritization. The current article describes only the QA/QC elements of INTERPRET NTA's MS<sup>1</sup> workflow, which are demonstrated using published data from a de facto water reuse study. INTERPRET NTA, in its current form, exists primarily to meet the needs of EPA and its partners, but a public release is planned. Workflows, terminology, and outputs of INTERPRET NTA provide a focal point for necessary discussions on the harmonization of NTA QA/QC practices.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":"1897-1914"},"PeriodicalIF":3.8000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-025-05771-w","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
The US Environmental Protection Agency (EPA) uses non-targeted analysis (NTA) to characterize potential risks associated with environmental pollutants and anthropogenic materials. NTA is used throughout EPA's Office of Research and Development (ORD) to support the needs of states, tribes, EPA regions, EPA program offices, and other outside partners. NTA methods are complex and conducted via myriad instrumental platforms and software products. Comprehensive standards do not yet exist to guide NTA quality assurance/quality control (QA/QC) procedures. Furthermore, no single software tool meets EPA's needs for QA/QC review and documentation. Considering these factors, ORD developed "INTERPRET NTA" (Interface for Processing, Reviewing, and Translating NTA data) to support liquid chromatography (LC) high-resolution mass spectrometry (HRMS) NTA experiments. For purposes of NTA QA/QC, INTERPRET NTA (1) calculates data quality statistics related to accuracy, precision, and reproducibility; (2) produces interactive visualizations to facilitate quality threshold optimization; and (3) outputs comprehensive documentation for inclusion in official reports and research publications. INTERPRET NTA has additional functionality to facilitate rapid chemical identification and risk-based prioritization. The current article describes only the QA/QC elements of INTERPRET NTA's MS1 workflow, which are demonstrated using published data from a de facto water reuse study. INTERPRET NTA, in its current form, exists primarily to meet the needs of EPA and its partners, but a public release is planned. Workflows, terminology, and outputs of INTERPRET NTA provide a focal point for necessary discussions on the harmonization of NTA QA/QC practices.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.