High-sensitive detection of Li and Zn in aqueous solutions using capillary effect-enhanced laser-induced breakdown spectroscopy

IF 5.6 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Yuanhang Wang , Yuwei Tian , Cong Liu , Zhixing Gao , Zhenlin Hu , Hongyu He , Daqing Yuan , Zhao Wang
{"title":"High-sensitive detection of Li and Zn in aqueous solutions using capillary effect-enhanced laser-induced breakdown spectroscopy","authors":"Yuanhang Wang ,&nbsp;Yuwei Tian ,&nbsp;Cong Liu ,&nbsp;Zhixing Gao ,&nbsp;Zhenlin Hu ,&nbsp;Hongyu He ,&nbsp;Daqing Yuan ,&nbsp;Zhao Wang","doi":"10.1016/j.talanta.2025.127707","DOIUrl":null,"url":null,"abstract":"<div><div>To ensure the safe operation of pressurized water reactors, the real-time and high-sensitive monitoring of Li and Zn in primary cooling water is required. Laser-induced breakdown spectroscopy (LIBS) is a real-time analytical method with great application potential for elemental monitoring in primary cooling water. However, when LIBS directly detects liquids, plasma quenching will reduce the detection sensitivity. In this work, capillary effect-enhanced LIBS (CE-LIBS) was proposed to improve the detection sensitivity of elements in aqueous solutions. Titanium foam substrates were used to enrich the solutes in the solutions. The signal enhancement mechanisms of the method were analyzed. The results showed that the solutes were enriched on the surface of the titanium foam substrate due to the capillary effect. The excitation temperature and electron density of the laser-induced plasma were both increased by the titanium foam substrate, thus increasing the plasma emission intensity. The limits of detection of Li and Zn were 0.41 and 3.83 ng/mL by using CE-LIBS, which can fully meet the requirements of Li and Zn monitoring in primary cooling water. The practicability of the method was demonstrated by analyzing simulated primary cooling water samples, and the recovery values of Li and Zn were in the range of 92–105 % and 96–102 %, respectively. The CE-LIBS does not require additional treatment of the substrate, and the detection process is simple and fast. Results indicated that the CE-LIBS method has broad application prospects in the real-time and high-sensitivity detection of elements in aqueous samples.</div></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"288 ","pages":"Article 127707"},"PeriodicalIF":5.6000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914025001936","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

To ensure the safe operation of pressurized water reactors, the real-time and high-sensitive monitoring of Li and Zn in primary cooling water is required. Laser-induced breakdown spectroscopy (LIBS) is a real-time analytical method with great application potential for elemental monitoring in primary cooling water. However, when LIBS directly detects liquids, plasma quenching will reduce the detection sensitivity. In this work, capillary effect-enhanced LIBS (CE-LIBS) was proposed to improve the detection sensitivity of elements in aqueous solutions. Titanium foam substrates were used to enrich the solutes in the solutions. The signal enhancement mechanisms of the method were analyzed. The results showed that the solutes were enriched on the surface of the titanium foam substrate due to the capillary effect. The excitation temperature and electron density of the laser-induced plasma were both increased by the titanium foam substrate, thus increasing the plasma emission intensity. The limits of detection of Li and Zn were 0.41 and 3.83 ng/mL by using CE-LIBS, which can fully meet the requirements of Li and Zn monitoring in primary cooling water. The practicability of the method was demonstrated by analyzing simulated primary cooling water samples, and the recovery values of Li and Zn were in the range of 92–105 % and 96–102 %, respectively. The CE-LIBS does not require additional treatment of the substrate, and the detection process is simple and fast. Results indicated that the CE-LIBS method has broad application prospects in the real-time and high-sensitivity detection of elements in aqueous samples.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信