Use of automated isovolemic hemodilution red-cell exchange in patients with sickle cell disease: A Canadian single center experience.

IF 2.5 3区 医学 Q2 HEMATOLOGY
Transfusion Pub Date : 2025-02-01 Epub Date: 2024-12-29 DOI:10.1111/trf.18119
Kelsey Uminski, Iris Perelman, Alan T Tinmouth, Johnathan Mack
{"title":"Use of automated isovolemic hemodilution red-cell exchange in patients with sickle cell disease: A Canadian single center experience.","authors":"Kelsey Uminski, Iris Perelman, Alan T Tinmouth, Johnathan Mack","doi":"10.1111/trf.18119","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Red cell exchange (RCE) is an important treatment for sickle cell disease (SCD). It is a resource-intensive intervention requiring large volumes of red blood cells (RBC), which are frequently antigen-matched. Efforts to reduce the volume of units transfused, while maintaining treatment efficacy is an important need. This study evaluates the impact of a change to isovolemic hemodilution (IHD)-RCE on RBC utilization in SCD patients at a Canadian center.</p><p><strong>Study design and methods: </strong>Adult SCD patients receiving chronic automated RCE at the Ottawa Hospital were approached for study inclusion. To safely attain a meaningful reduction in transfused RBCs, RCE parameters were individualized for each patient. IHD-RCE was performed only if an estimated reduction in RBC volume of at least 200 mL was expected, with hematocrit not allowed to decrease below 20%. Data were compared in the 6-months before and after the protocol change.</p><p><strong>Results: </strong>Twenty-two adult patients met the criteria for inclusion. There was a net reduction of 107 RBC units after the transition from standard RCE to IHD-RCE (1035 vs. 928 units; -10.3%). The mean number of RBC units transfused per patient decreased by 4.8 (47.0 vs. 42.2 units; p = .01). No difference in target post-RCE hemoglobin S levels was observed.</p><p><strong>Discussion: </strong>In this study IHD-RCE reduced RBC utilization without impacting efficacy or safety, conserving 107 RBC units (an annualized savings of $95,444 CAD). No adverse events due to saline replacement were observed. Increased awareness of the benefits of IHD-RCE through knowledge translation could promote greater uptake.</p>","PeriodicalId":23266,"journal":{"name":"Transfusion","volume":"65 2","pages":"325-332"},"PeriodicalIF":2.5000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/trf.18119","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Red cell exchange (RCE) is an important treatment for sickle cell disease (SCD). It is a resource-intensive intervention requiring large volumes of red blood cells (RBC), which are frequently antigen-matched. Efforts to reduce the volume of units transfused, while maintaining treatment efficacy is an important need. This study evaluates the impact of a change to isovolemic hemodilution (IHD)-RCE on RBC utilization in SCD patients at a Canadian center.

Study design and methods: Adult SCD patients receiving chronic automated RCE at the Ottawa Hospital were approached for study inclusion. To safely attain a meaningful reduction in transfused RBCs, RCE parameters were individualized for each patient. IHD-RCE was performed only if an estimated reduction in RBC volume of at least 200 mL was expected, with hematocrit not allowed to decrease below 20%. Data were compared in the 6-months before and after the protocol change.

Results: Twenty-two adult patients met the criteria for inclusion. There was a net reduction of 107 RBC units after the transition from standard RCE to IHD-RCE (1035 vs. 928 units; -10.3%). The mean number of RBC units transfused per patient decreased by 4.8 (47.0 vs. 42.2 units; p = .01). No difference in target post-RCE hemoglobin S levels was observed.

Discussion: In this study IHD-RCE reduced RBC utilization without impacting efficacy or safety, conserving 107 RBC units (an annualized savings of $95,444 CAD). No adverse events due to saline replacement were observed. Increased awareness of the benefits of IHD-RCE through knowledge translation could promote greater uptake.

在镰状细胞病患者中使用自动等容量血液稀释红细胞交换技术:加拿大单中心经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Transfusion
Transfusion 医学-血液学
CiteScore
4.70
自引率
20.70%
发文量
426
审稿时长
1 months
期刊介绍: TRANSFUSION is the foremost publication in the world for new information regarding transfusion medicine. Written by and for members of AABB and other health-care workers, TRANSFUSION reports on the latest technical advances, discusses opposing viewpoints regarding controversial issues, and presents key conference proceedings. In addition to blood banking and transfusion medicine topics, TRANSFUSION presents submissions concerning patient blood management, tissue transplantation and hematopoietic, cellular, and gene therapies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信