Validation of an Environmental Exposure Chamber for Assessment of Allergy to Grass Pollen.

IF 6.1 3区 医学 Q1 ALLERGY
I García-Gutiérrez, C Solórzano-Zepeda, V Sánchez-García, E Ramírez-Mateo, D Antolín-Amérigo, Y Zheng, A Rioja Carrera, I León Hernando, M E Hernando Pérez, B De la Hoz Caballer
{"title":"Validation of an Environmental Exposure Chamber for Assessment of Allergy to Grass Pollen.","authors":"I García-Gutiérrez, C Solórzano-Zepeda, V Sánchez-García, E Ramírez-Mateo, D Antolín-Amérigo, Y Zheng, A Rioja Carrera, I León Hernando, M E Hernando Pérez, B De la Hoz Caballer","doi":"10.18176/jiaci.1036","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>An environmental exposure chamber (EEC) is a health facility that enables allergic symptoms to be induced in a controlled manner in persons sensitized to a dispersed allergen. We performed a study at our institution to technically and clinically validate an EEC in patients allergic to grass pollen.</p><p><strong>Methods: </strong>We developed a new EEC inside a clean room (ISO-8 class) measuring 15.6 m². During the technical validation, the patient's exposure conditions were simulated by ensuring homogeneous distribution of the allergen with a particle disperser and monitoring both particle and pollen grain concentrations. Temperature, pressure, and humidity were also registered. A total of 31 volunteers were exposed to Phleum pratense pollen in the EEC. Of these, 25 were allergic (cases), with symptoms of rhinoconjunctivitis with or without asthma, and 6 were not (controls). One control and 2 cases were exposed twice to check reproducibility, generating a total of 34 challenges. The test was stopped once the positivity criterion was reached or the patient completed 90 minutes in the EEC.</p><p><strong>Results: </strong>Both the stability of particle concentrations and approximation to the pollen sample concentration were guaranteed. All challenges with controls were negative. Among the cases, 15% of challenges were negative and 85% were positive. No severe or late reactions were observed. Volunteers exposed twice to the same pollen had the same result in both challenges.</p><p><strong>Conclusion: </strong>Our EEC proved to be a specific, safe, and reproducible tool for the diagnosis of grass pollen allergy.</p>","PeriodicalId":50173,"journal":{"name":"Journal of Investigational Allergology and Clinical Immunology","volume":" ","pages":"0"},"PeriodicalIF":6.1000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Investigational Allergology and Clinical Immunology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.18176/jiaci.1036","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ALLERGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: An environmental exposure chamber (EEC) is a health facility that enables allergic symptoms to be induced in a controlled manner in persons sensitized to a dispersed allergen. We performed a study at our institution to technically and clinically validate an EEC in patients allergic to grass pollen.

Methods: We developed a new EEC inside a clean room (ISO-8 class) measuring 15.6 m². During the technical validation, the patient's exposure conditions were simulated by ensuring homogeneous distribution of the allergen with a particle disperser and monitoring both particle and pollen grain concentrations. Temperature, pressure, and humidity were also registered. A total of 31 volunteers were exposed to Phleum pratense pollen in the EEC. Of these, 25 were allergic (cases), with symptoms of rhinoconjunctivitis with or without asthma, and 6 were not (controls). One control and 2 cases were exposed twice to check reproducibility, generating a total of 34 challenges. The test was stopped once the positivity criterion was reached or the patient completed 90 minutes in the EEC.

Results: Both the stability of particle concentrations and approximation to the pollen sample concentration were guaranteed. All challenges with controls were negative. Among the cases, 15% of challenges were negative and 85% were positive. No severe or late reactions were observed. Volunteers exposed twice to the same pollen had the same result in both challenges.

Conclusion: Our EEC proved to be a specific, safe, and reproducible tool for the diagnosis of grass pollen allergy.

评估草花粉过敏的环境暴露室的验证。
背景:环境暴露室(EEC)是一种卫生设施,可使对分散的过敏原敏感的人以可控的方式诱发过敏症状。我们在我们的机构进行了一项研究,以技术和临床验证对草花粉过敏的患者的EEC。方法:在15.6 m²的无尘室(ISO-8级)内建立新的EEC。在技术验证过程中,通过使用颗粒分散器确保过敏原均匀分布并监测颗粒和花粉粒浓度来模拟患者的暴露条件。温度、压力和湿度也被记录了下来。共有31名志愿者在EEC中暴露于花粉。其中25例为过敏性(病例),伴有或不伴有哮喘的鼻结膜炎症状,6例为非过敏性(对照组)。1例对照和2例病例暴露两次以检查再现性,共产生34个挑战。一旦达到阳性标准或患者在EEC中完成90分钟,则停止测试。结果:保证了颗粒浓度的稳定性和与花粉样品浓度的近似性。所有控制挑战都是消极的。在这些案例中,15%的挑战是负面的,85%是正面的。未见严重或晚期反应。志愿者两次接触相同的花粉,在两次挑战中都得到了相同的结果。结论:EEC是一种特异性、安全性和可重复性高的草花粉过敏诊断工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.10
自引率
9.70%
发文量
135
审稿时长
6-12 weeks
期刊介绍: The Journal of Investigational Allergology and Clinical Immunology (J Investig Allergol Clin Immunol) provides an attractive and very active forum for basic and clinical research in allergology and clinical immunology.Journal of Investigational Allergology and Clinical Immunology publishes original works, reviews, short communications and opinions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信