Evaluation of Safety and Effectiveness of the LISTENT LCI-20PI Cochlear Implant in Post-Lingually Deafened Individuals.

Qiang Du, Zengjun Sun, Weijia Kong, Hao Wu, Yun Li, Qi Huang, Chunfu Dai
{"title":"Evaluation of Safety and Effectiveness of the LISTENT LCI-20PI Cochlear Implant in Post-Lingually Deafened Individuals.","authors":"Qiang Du, Zengjun Sun, Weijia Kong, Hao Wu, Yun Li, Qi Huang, Chunfu Dai","doi":"10.5152/iao.2025.241627","DOIUrl":null,"url":null,"abstract":"<p><p>Background: Cochlear implantation is safe and effective in restoring hearing and speech recognition abilities for individuals with severe to profound sensorineural hearing loss. This prospective multicenter clinical trial was conducted to evaluate the safety and effectiveness of a novel cochlear implant (CI) system, the LISTENT LCI-20PI device, in post-lingually deafened individuals. Methods: The LCI-20PI CI system was implanted in 70 individuals 6-68 (27.7 ± 14.0) years old. The safety and effectiveness of the devices were evaluated during a 1-year follow-up. Results: Electrically evoked compound action potential were successfully measured in 98.6% (69/70) of subjects. Electrode impedance was within normal limits of 0.7-20 kOhm in 99.8% of cases. All subjective T/C levels were successfully measured on the selected 12 electrodes of the LCI-20PI recipients at device activation and 1 month, 3 months, 6 months, and 12 months post-activation. The mean open-set monosyllabic-word recognition score (MRS), disyllabic-word recognition score (DRS), and sentence recognition score (SRS) were 28.9 ± 21.0%, 30.3 ± 25.8%, and 36.3 ± 36.3% at 6 months post-activation, and 57.1 ± 21.1%, 69.1 ± 24.4%, and 89.7 ± 21.5% at 12 months post-activation, respectively. Sex, side of the ear implanted, residual hearing, duration of deafness, etiology of deafness, and surgeon did not influence postoperative speech recognition performance. Conclusion: The novel LCI-20PI CI device is safe and effective in post-lingually deafened recipients.</p>","PeriodicalId":94238,"journal":{"name":"The journal of international advanced otology","volume":"21 1","pages":"1-8"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11843266/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of international advanced otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/iao.2025.241627","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cochlear implantation is safe and effective in restoring hearing and speech recognition abilities for individuals with severe to profound sensorineural hearing loss. This prospective multicenter clinical trial was conducted to evaluate the safety and effectiveness of a novel cochlear implant (CI) system, the LISTENT LCI-20PI device, in post-lingually deafened individuals. Methods: The LCI-20PI CI system was implanted in 70 individuals 6-68 (27.7 ± 14.0) years old. The safety and effectiveness of the devices were evaluated during a 1-year follow-up. Results: Electrically evoked compound action potential were successfully measured in 98.6% (69/70) of subjects. Electrode impedance was within normal limits of 0.7-20 kOhm in 99.8% of cases. All subjective T/C levels were successfully measured on the selected 12 electrodes of the LCI-20PI recipients at device activation and 1 month, 3 months, 6 months, and 12 months post-activation. The mean open-set monosyllabic-word recognition score (MRS), disyllabic-word recognition score (DRS), and sentence recognition score (SRS) were 28.9 ± 21.0%, 30.3 ± 25.8%, and 36.3 ± 36.3% at 6 months post-activation, and 57.1 ± 21.1%, 69.1 ± 24.4%, and 89.7 ± 21.5% at 12 months post-activation, respectively. Sex, side of the ear implanted, residual hearing, duration of deafness, etiology of deafness, and surgeon did not influence postoperative speech recognition performance. Conclusion: The novel LCI-20PI CI device is safe and effective in post-lingually deafened recipients.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信