Wearable CNT/PAni/fabric piezoresistive sensor for continuous blood pressure monitoring.

IF 3.4 Q2 ENGINEERING, BIOMEDICAL
Wearable technologies Pub Date : 2025-02-10 eCollection Date: 2025-01-01 DOI:10.1017/wtc.2024.31
Milad Barati, Alireza Nikfarjam
{"title":"Wearable CNT/PAni/fabric piezoresistive sensor for continuous blood pressure monitoring.","authors":"Milad Barati, Alireza Nikfarjam","doi":"10.1017/wtc.2024.31","DOIUrl":null,"url":null,"abstract":"<p><p>Wearable pressure sensors with high sensitivity, fast response time, and low detection limit have great potential for blood pressure monitoring and early diagnosis of hypertension. This article introduces a piezoresistive pressure sensor based on carbon nanotubes (CNTs), polyaniline (PAni), and fabric (CNT/PAni/fabric) for health monitoring applications. This sensor is made by using two layers of linen fabric coated with CNT and PAni. These layers are placed on a polyester fabric substrate. One of the coated layers has a mesh structure, which increases the sensitivity of the sensor and lowers its detection limit. The CNT/PAni/fabric sensor has a high sensitivity of 2.035 kPa<sup>-1</sup> at pressures from 0 to 0.2 kPa, a response time of 290 ms, and a detection limit of 1.5 Pa. These features make it suitable for measuring blood pressure. The results obtained by measuring blood pressure using the pulse transit time method on four people, compared with the values obtained using the digital sphygmomanometer, show a discrepancy ranging between 0.019% and 1.62%. Also, the average error and standard deviation for the sensor measurement in systolic and diastolic pressures are 0.56 ± 0.33 and 0.57 ± 0.46, respectively, which shows that measurement with this sensor can be an alternative to existing devices.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":"6 ","pages":"e6"},"PeriodicalIF":3.4000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11810520/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2024.31","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Wearable pressure sensors with high sensitivity, fast response time, and low detection limit have great potential for blood pressure monitoring and early diagnosis of hypertension. This article introduces a piezoresistive pressure sensor based on carbon nanotubes (CNTs), polyaniline (PAni), and fabric (CNT/PAni/fabric) for health monitoring applications. This sensor is made by using two layers of linen fabric coated with CNT and PAni. These layers are placed on a polyester fabric substrate. One of the coated layers has a mesh structure, which increases the sensitivity of the sensor and lowers its detection limit. The CNT/PAni/fabric sensor has a high sensitivity of 2.035 kPa-1 at pressures from 0 to 0.2 kPa, a response time of 290 ms, and a detection limit of 1.5 Pa. These features make it suitable for measuring blood pressure. The results obtained by measuring blood pressure using the pulse transit time method on four people, compared with the values obtained using the digital sphygmomanometer, show a discrepancy ranging between 0.019% and 1.62%. Also, the average error and standard deviation for the sensor measurement in systolic and diastolic pressures are 0.56 ± 0.33 and 0.57 ± 0.46, respectively, which shows that measurement with this sensor can be an alternative to existing devices.

可穿戴CNT/聚苯胺/织物压阻式传感器,用于连续血压监测。
穿戴式压力传感器灵敏度高、响应时间快、检出限低,在血压监测和高血压早期诊断方面具有很大的潜力。本文介绍了一种基于碳纳米管(CNTs)、聚苯胺(PAni)和织物(CNT/PAni/织物)的压阻式压力传感器,用于健康监测应用。该传感器由两层涂有碳纳米管和聚苯胺的亚麻织物制成。这些层被放置在聚酯织物基底上。其中一层涂层具有网状结构,这增加了传感器的灵敏度并降低了其检测极限。该CNT/PAni/织物传感器在0 ~ 0.2 kPa的压力范围内具有2.035 kPa-1的高灵敏度,响应时间为290 ms,检测极限为1.5 Pa。这些特点使它适合测量血压。用脉搏传递时间法测量四个人的血压,与数字血压计测量的结果相比,差异在0.019% ~ 1.62%之间。此外,传感器测量收缩压和舒张压的平均误差和标准偏差分别为0.56±0.33和0.57±0.46,这表明该传感器可以替代现有设备进行测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信