Assessing scleral toricity induced lens flexure and contact disparity using anterior segment optical coherence tomography.

IF 4.1 3区 医学 Q1 OPHTHALMOLOGY
Eihab Eltantawy
{"title":"Assessing scleral toricity induced lens flexure and contact disparity using anterior segment optical coherence tomography.","authors":"Eihab Eltantawy","doi":"10.1016/j.clae.2025.102386","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the influence of scleral toricity on the extent of lens contact and in-vivo flexure using anterior segment optical coherence tomography (AS-OCT), and to identify variables related to lens decentration.</p><p><strong>Methods: </strong>Scleral toricity at a chord of 15 mm was measured using Pentacam corneoscleral profilometry (CSP) from 10 healthy young participants (22 ± 2 years) with normal corneas. Participants were fitted with the same 16.0 mm rotationally symmetric scleral lens design (hexafocon A material). AS-OCT was used in conjunction with ImageJ analysis to document the disparity of lens contact at the 15 mm chord primary toric meridians and to assess lens flexure. Additionally, central fluid reservoir (FR) depth and lens decentration were measured.</p><p><strong>Results: </strong>A significant correlation was found between scleral toricity (mean 155 ± 95 μm) and both the magnitude of lens flexure, and the disparity in lens contact between the scleral primary toric meridians at the 15 mm chord diameter (r = 0.83, p = 0.003 and r<sub>s</sub> = 0.83, p = 0.005 respectively). Mean lens decentration values were 0.30 ± 0.18 mm inferior-temporal net decentration, 0.26 ± 0.16 mm inferior decentration and 0.13 ± 0.1 mm temporal decentration. This was significantly associated with central FR depth (r<sub>s</sub> = 0.91, p = 0.0005 and r<sub>s</sub> = 0.73, p = 0.02 and r<sub>s</sub> = 0.71, p = 0.03 respectively). No significant correlation was found between lens decentration and scleral toricity (p > 0.05).</p><p><strong>Conclusion: </strong>Scleral toricity was significantly associated with AS-OCT measured lens flexure and contact disparity at primary toric landing locations defined by profilometry. Reducing central FR depth appears to be a good strategy for improved lens centration. Whilst equalising lens contact along toric meridians is beneficial for addressing lens flexure, the influence of this on centration is less clear.</p>","PeriodicalId":49087,"journal":{"name":"Contact Lens & Anterior Eye","volume":" ","pages":"102386"},"PeriodicalIF":4.1000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Lens & Anterior Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clae.2025.102386","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To determine the influence of scleral toricity on the extent of lens contact and in-vivo flexure using anterior segment optical coherence tomography (AS-OCT), and to identify variables related to lens decentration.

Methods: Scleral toricity at a chord of 15 mm was measured using Pentacam corneoscleral profilometry (CSP) from 10 healthy young participants (22 ± 2 years) with normal corneas. Participants were fitted with the same 16.0 mm rotationally symmetric scleral lens design (hexafocon A material). AS-OCT was used in conjunction with ImageJ analysis to document the disparity of lens contact at the 15 mm chord primary toric meridians and to assess lens flexure. Additionally, central fluid reservoir (FR) depth and lens decentration were measured.

Results: A significant correlation was found between scleral toricity (mean 155 ± 95 μm) and both the magnitude of lens flexure, and the disparity in lens contact between the scleral primary toric meridians at the 15 mm chord diameter (r = 0.83, p = 0.003 and rs = 0.83, p = 0.005 respectively). Mean lens decentration values were 0.30 ± 0.18 mm inferior-temporal net decentration, 0.26 ± 0.16 mm inferior decentration and 0.13 ± 0.1 mm temporal decentration. This was significantly associated with central FR depth (rs = 0.91, p = 0.0005 and rs = 0.73, p = 0.02 and rs = 0.71, p = 0.03 respectively). No significant correlation was found between lens decentration and scleral toricity (p > 0.05).

Conclusion: Scleral toricity was significantly associated with AS-OCT measured lens flexure and contact disparity at primary toric landing locations defined by profilometry. Reducing central FR depth appears to be a good strategy for improved lens centration. Whilst equalising lens contact along toric meridians is beneficial for addressing lens flexure, the influence of this on centration is less clear.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.60
自引率
18.80%
发文量
198
审稿时长
55 days
期刊介绍: Contact Lens & Anterior Eye is a research-based journal covering all aspects of contact lens theory and practice, including original articles on invention and innovations, as well as the regular features of: Case Reports; Literary Reviews; Editorials; Instrumentation and Techniques and Dates of Professional Meetings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信