Evaluation of Bladder Wash as an Alternative Specimen for Postmortem Toxicology: Comparison to Screening Results of Urine and Kidney Tissue.

IF 2.6 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Andrea E Steuer, Lana Brockbals, Sandra N Poetzsch, Stephan A Bolliger, Thomas Kraemer
{"title":"Evaluation of Bladder Wash as an Alternative Specimen for Postmortem Toxicology: Comparison to Screening Results of Urine and Kidney Tissue.","authors":"Andrea E Steuer, Lana Brockbals, Sandra N Poetzsch, Stephan A Bolliger, Thomas Kraemer","doi":"10.1002/dta.3861","DOIUrl":null,"url":null,"abstract":"<p><p>Urine specimens represent the gold standard for screening analyses in forensic toxicology, but they are not always available postmortem. In this case, alternative specimens must be considered. The current study aimed to systematically evaluate bladder wash (BW) as an interesting, but largely unexplored specimen for screening in FT, comparing drug detection in BW against urine and kidney tissue (KT) in authentic cases. The study included 60 consecutive postmortem cases. BW was obtained by injecting 10 mL of a 0.9% NaCl solution into the empty bladder and sampling the entire fluid with the same syringe. KT (ca. 5 g, grinded) was placed into a tube of dialysis membrane and left for dialysis against water (3×, 40-80 mL, 24 h), followed by evaporation/reconstitution. All specimens were analyzed by immunoassay, an untargeted LC-MS<sup>n</sup> screening approach and a targeted LC-MS/MS analysis. In total, 95 different compounds from the drug classes of, among others, stimulants, opiates/opioids, benzodiazepines, antidepressants, and antipsychotics could be detected. Sensitivity for drug detection in BW using immunoassay or untargeted MS/MS was lower than for urine but comparable to that of KT, which is in line with much lower drug concentrations in these matrices compared with urine. Applying a targeted LC-MS/MS method or a more concentrated sample preparation workflow could increase detection sensitivity in BW. Given the easier handling of BW in the laboratory (identical to urine), its use proved superior to KT and represents a promising new strategy for cases without available urine samples.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/dta.3861","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Urine specimens represent the gold standard for screening analyses in forensic toxicology, but they are not always available postmortem. In this case, alternative specimens must be considered. The current study aimed to systematically evaluate bladder wash (BW) as an interesting, but largely unexplored specimen for screening in FT, comparing drug detection in BW against urine and kidney tissue (KT) in authentic cases. The study included 60 consecutive postmortem cases. BW was obtained by injecting 10 mL of a 0.9% NaCl solution into the empty bladder and sampling the entire fluid with the same syringe. KT (ca. 5 g, grinded) was placed into a tube of dialysis membrane and left for dialysis against water (3×, 40-80 mL, 24 h), followed by evaporation/reconstitution. All specimens were analyzed by immunoassay, an untargeted LC-MSn screening approach and a targeted LC-MS/MS analysis. In total, 95 different compounds from the drug classes of, among others, stimulants, opiates/opioids, benzodiazepines, antidepressants, and antipsychotics could be detected. Sensitivity for drug detection in BW using immunoassay or untargeted MS/MS was lower than for urine but comparable to that of KT, which is in line with much lower drug concentrations in these matrices compared with urine. Applying a targeted LC-MS/MS method or a more concentrated sample preparation workflow could increase detection sensitivity in BW. Given the easier handling of BW in the laboratory (identical to urine), its use proved superior to KT and represents a promising new strategy for cases without available urine samples.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Drug Testing and Analysis
Drug Testing and Analysis BIOCHEMICAL RESEARCH METHODS-CHEMISTRY, ANALYTICAL
CiteScore
5.90
自引率
24.10%
发文量
191
审稿时长
2.3 months
期刊介绍: As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances. In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds). Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信