Self-Fitting Hearing Aids: Effects of Starting Response and Field Experience.

IF 2.6 2区 医学 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Arthur Boothroyd, Dhiman Sengupta, Shaelyn Painter, Elena Shur, Harinath Garudadri, Carol Mackersie
{"title":"Self-Fitting Hearing Aids: Effects of Starting Response and Field Experience.","authors":"Arthur Boothroyd, Dhiman Sengupta, Shaelyn Painter, Elena Shur, Harinath Garudadri, Carol Mackersie","doi":"10.1097/AUD.0000000000001642","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To determine the effects of changing from a prescribed to a generic starting response on self-fitting outcome and behavior before and after a brief field experience.</p><p><strong>Method: </strong>Twenty adult hearing-aid users with mild-to-moderate hearing loss used a smartphone interface to adjust level and spectral tilt of the output of a wearable master hearing aid while listening to prerecorded speech, presented at 65 dB SPL, in quiet. A prescribed starting response was based on the participant's own audiogram. A generic starting response was based on an audiogram for a typical mild-to-moderate hearing loss and was the same for all participants. Initial self-fittings from the two starting responses took place in the lab. After a brief field experience, involving conversation, self-hearing, and ambient noise, with readjustment as needed, self-fittings from the two starting responses were repeated in the lab. Starting responses, self-fitted responses, and adjustment steps were logged in the master hearing aid for subsequent evaluation of real-ear output spectra and for assessment of self-fitting behavior.</p><p><strong>Results: </strong>Neither starting response nor field experience had a significant effect on mean self-fitted output in the lab (p = 0.506 and 0.149, respectively). However, the SD of individual starting-response effects on high-frequency self-fitted output fell by around 50% after the field experience (p = 0.006). The effect of starting response on self-fitting behavior was limited to number of adjustment steps, which was higher for the generic start (p = 0.014). The effect of field experience on self-fitting behavior was limited to a 50% reduction in self-fitting time (p < 0.001). This reduction was attributable mainly to less time spent listening after each adjustment step (p = 0.019).</p><p><strong>Conclusions: </strong>The findings support the conclusion that, for a population with mild-to-moderate hearing loss, a generic starting response can be a viable option for over-the-counter self-fitting hearing aids. They highlight, however, the need for practice and experience with novel self-fitting hearing aids and the fact that self-fitting may not be suitable for all.</p>","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/AUD.0000000000001642","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To determine the effects of changing from a prescribed to a generic starting response on self-fitting outcome and behavior before and after a brief field experience.

Method: Twenty adult hearing-aid users with mild-to-moderate hearing loss used a smartphone interface to adjust level and spectral tilt of the output of a wearable master hearing aid while listening to prerecorded speech, presented at 65 dB SPL, in quiet. A prescribed starting response was based on the participant's own audiogram. A generic starting response was based on an audiogram for a typical mild-to-moderate hearing loss and was the same for all participants. Initial self-fittings from the two starting responses took place in the lab. After a brief field experience, involving conversation, self-hearing, and ambient noise, with readjustment as needed, self-fittings from the two starting responses were repeated in the lab. Starting responses, self-fitted responses, and adjustment steps were logged in the master hearing aid for subsequent evaluation of real-ear output spectra and for assessment of self-fitting behavior.

Results: Neither starting response nor field experience had a significant effect on mean self-fitted output in the lab (p = 0.506 and 0.149, respectively). However, the SD of individual starting-response effects on high-frequency self-fitted output fell by around 50% after the field experience (p = 0.006). The effect of starting response on self-fitting behavior was limited to number of adjustment steps, which was higher for the generic start (p = 0.014). The effect of field experience on self-fitting behavior was limited to a 50% reduction in self-fitting time (p < 0.001). This reduction was attributable mainly to less time spent listening after each adjustment step (p = 0.019).

Conclusions: The findings support the conclusion that, for a population with mild-to-moderate hearing loss, a generic starting response can be a viable option for over-the-counter self-fitting hearing aids. They highlight, however, the need for practice and experience with novel self-fitting hearing aids and the fact that self-fitting may not be suitable for all.

自适应助听器:启动反应和现场经验的影响。
目的:确定在简短的现场体验前后,从规定的开始反应到一般的开始反应对自拟合结果和行为的影响。方法:20名轻度至中度听力损失的成年助听器用户在安静环境下,使用智能手机界面调节可穿戴主助听器的输出电平和频谱倾斜,同时收听预先录制的65 dB SPL语音。一个规定的开始反应是基于参与者自己的听力图。一般的开始反应是基于典型的轻度至中度听力损失的听力图,所有参与者都是一样的。两种初始反应的初始自我匹配是在实验室中进行的。经过简短的现场体验,包括对话、自我听力和环境噪音,并根据需要进行调整,在实验室中重复了两种开始反应的自我适配。启动响应、自拟合响应和调整步骤被记录在主助听器中,以便后续评估实耳输出频谱和评估自拟合行为。结果:启动反应和现场经验对实验室的平均自拟输出都没有显著影响(p分别= 0.506和0.149)。然而,经过现场经验后,个体启动响应效应对高频自拟输出的SD下降了约50% (p = 0.006)。启动反应对自拟合行为的影响仅限于调整步数,而通用启动的影响更大(p = 0.014)。现场经验对自拟合行为的影响仅限于将自拟合时间减少50% (p < 0.001)。这种减少主要归因于每个调整步骤后倾听的时间减少(p = 0.019)。结论:研究结果支持这样的结论:对于轻度至中度听力损失的人群,通用的起始反应可能是非处方自配助听器的可行选择。然而,他们强调了使用新型自配助听器的实践和经验的必要性,以及自配助听器可能并不适合所有人的事实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ear and Hearing
Ear and Hearing 医学-耳鼻喉科学
CiteScore
5.90
自引率
10.80%
发文量
207
审稿时长
6-12 weeks
期刊介绍: From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信