Pichia kudriavzevii (JD2) Immobilized on Acid Activated Perlite as a Biosorbent for Solid Phase Extraction of Cr(III) Determination by AAS (Atomic Adsorption Spectroscopy)

IF 2 3区 工程技术 Q2 ANATOMY & MORPHOLOGY
Aliya Amanzhol, Özcan Yalçınkaya, Berat Çinar Acar, Zehranur Yuksekdag
{"title":"Pichia kudriavzevii (JD2) Immobilized on Acid Activated Perlite as a Biosorbent for Solid Phase Extraction of Cr(III) Determination by AAS (Atomic Adsorption Spectroscopy)","authors":"Aliya Amanzhol,&nbsp;Özcan Yalçınkaya,&nbsp;Berat Çinar Acar,&nbsp;Zehranur Yuksekdag","doi":"10.1002/jemt.24815","DOIUrl":null,"url":null,"abstract":"<p>In this study, the preconcentration of Cr(III) ion in <i>Pichia kudriavzevii</i> JD2 immobilized perlite adsorbent by solid phase extraction was investigated. The determination of Cr(III) was performed using flame atomic absorption spectrometry (AAS). The effects of pH, adsorbent amount, recovery solution volume and type, and sample solution flow rate and volume on the recovery efficiency of Cr(III) ions were investigated. Optimized preconcentration conditions for Cr(III) were established using a column technique. The optimal parameters were determined as pH 4, a recovery solution of 2 mol/L HNO<sub>3</sub> with a volume of 10 mL, and a sample flow rate of 1–3 mL/min, preconcentration factor 25. Under these conditions, the recovery efficiency of Cr(III) ion on perlite immobilized with <i>Pichia kudriavzevii</i> JD2 was found to be 100.1% ± 0.3% with a 95% confidence level. Analytical variables with a limit of detection (LOD) of 4.8 μg/L and a limit of quantification (LOQ) of 15.8 μg/L were determined for the Cr(III) ion. The accuracy of the method was determined using standard reference materials (SPS-WW1). The relative error of the recovery efficiency was determined to be less than 10%. The method was applied to the determination of Cr(III) in various water samples, such as tap water and mineral waters.</p>","PeriodicalId":18684,"journal":{"name":"Microscopy Research and Technique","volume":"88 6","pages":"1765-1783"},"PeriodicalIF":2.0000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jemt.24815","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy Research and Technique","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jemt.24815","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the preconcentration of Cr(III) ion in Pichia kudriavzevii JD2 immobilized perlite adsorbent by solid phase extraction was investigated. The determination of Cr(III) was performed using flame atomic absorption spectrometry (AAS). The effects of pH, adsorbent amount, recovery solution volume and type, and sample solution flow rate and volume on the recovery efficiency of Cr(III) ions were investigated. Optimized preconcentration conditions for Cr(III) were established using a column technique. The optimal parameters were determined as pH 4, a recovery solution of 2 mol/L HNO3 with a volume of 10 mL, and a sample flow rate of 1–3 mL/min, preconcentration factor 25. Under these conditions, the recovery efficiency of Cr(III) ion on perlite immobilized with Pichia kudriavzevii JD2 was found to be 100.1% ± 0.3% with a 95% confidence level. Analytical variables with a limit of detection (LOD) of 4.8 μg/L and a limit of quantification (LOQ) of 15.8 μg/L were determined for the Cr(III) ion. The accuracy of the method was determined using standard reference materials (SPS-WW1). The relative error of the recovery efficiency was determined to be less than 10%. The method was applied to the determination of Cr(III) in various water samples, such as tap water and mineral waters.

酸活化珠光岩固定化Pichia kudriavzevii (JD2)作为生物吸附剂固相萃取Cr(III)的原子吸附光谱法测定。
研究了固相萃取法在毕赤酵母(Pichia kudriavzevii) JD2固定化珠光岩吸附剂中预富集Cr(III)离子。采用火焰原子吸收光谱法(AAS)测定Cr(III)。考察了pH、吸附剂用量、回收溶液体积和类型、样品溶液流速和体积对Cr(III)离子回收率的影响。采用柱法确定了Cr(III)的最佳富集条件。确定最佳工艺参数为pH为4,回收液为2 mol/L HNO3,体积为10 mL,样品流速为1 ~ 3 mL/min,预浓缩系数为25。在此条件下,用毕赤酵母(Pichia kudriavzevii JD2)固定化珠光岩对Cr(III)离子的回收率为100.1%±0.3%,置信水平为95%。测定的分析变量对Cr(III)离子的检测限为4.8 μg/L,定量限为15.8 μg/L。采用标准对照品(SPS-WW1)测定方法的准确度。测定的回收率相对误差小于10%。该方法适用于自来水、矿泉水等各种水样中铬(III)的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Microscopy Research and Technique
Microscopy Research and Technique 医学-解剖学与形态学
CiteScore
5.30
自引率
20.00%
发文量
233
审稿时长
4.7 months
期刊介绍: Microscopy Research and Technique (MRT) publishes articles on all aspects of advanced microscopy original architecture and methodologies with applications in the biological, clinical, chemical, and materials sciences. Original basic and applied research as well as technical papers dealing with the various subsets of microscopy are encouraged. MRT is the right form for those developing new microscopy methods or using the microscope to answer key questions in basic and applied research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信