A simultaneous detection method for eight iodinated, brominated, and chlorinated haloacetic acid disinfection byproducts in human urine: liquid-liquid extraction-acidified methanol derivatization-gas chromatography.

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Xue Bai, Lanxia Liu, Jiefeng Qian, Rui Liu, Zhiyuan Du, Rong Ni, Tian Chen, Weiwei Zheng
{"title":"A simultaneous detection method for eight iodinated, brominated, and chlorinated haloacetic acid disinfection byproducts in human urine: liquid-liquid extraction-acidified methanol derivatization-gas chromatography.","authors":"Xue Bai, Lanxia Liu, Jiefeng Qian, Rui Liu, Zhiyuan Du, Rong Ni, Tian Chen, Weiwei Zheng","doi":"10.1039/d4ay02254h","DOIUrl":null,"url":null,"abstract":"<p><p>Haloacetic acids (HAAs) are among the most common drinking water disinfection byproducts (DBPs) and are of widespread concern due to their potential carcinogenicity and reproductive health risks. However, data on human exposure to HAAs are scarce. HAAs in urine have been identified as useful biomarkers for assessing exposure to DBPs <i>via</i> drinking chlorinated water. In this study, a suitable method for determining eight HAAs (including iodoacetic acid (IAA)) in human urine was developed and validated based on USEPA 552.3. HAAs were extracted from 5 mL of urine with methyl <i>tert</i>-butyl ether (MTBE), derivatized with acidified methanol and analyzed <i>via</i> gas chromatography with an electron capture detector (GC-ECD). Several optimization experiments were performed for the sample pretreatment step to establish a more sensitive and efficient analysis scheme. The method was tested in terms of linearity, accuracy, precision, and detection limits. The linear range of the method was 0.1-100 μg L<sup>-1</sup>, with recovery rates from blank matrix-spiked samples ranging from 84.9% to 122.6%, relative standard deviations between 1.7% and 14.2%, detection limits from 0.013 to 0.3 μg L<sup>-1</sup>, and quantitation limits from 0.043 to 1.0 μg L<sup>-1</sup>. Finally, the method was applied to detect HAAs in actual human urine samples. Six HAAs were detected in 460 urine samples to varying degrees, with geometric mean concentrations ranging from 0.07 to 0.89 μg L<sup>-1</sup>. The results demonstrate that the method is practical, and suitable for routine biomonitoring of HAAs in populations.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay02254h","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Haloacetic acids (HAAs) are among the most common drinking water disinfection byproducts (DBPs) and are of widespread concern due to their potential carcinogenicity and reproductive health risks. However, data on human exposure to HAAs are scarce. HAAs in urine have been identified as useful biomarkers for assessing exposure to DBPs via drinking chlorinated water. In this study, a suitable method for determining eight HAAs (including iodoacetic acid (IAA)) in human urine was developed and validated based on USEPA 552.3. HAAs were extracted from 5 mL of urine with methyl tert-butyl ether (MTBE), derivatized with acidified methanol and analyzed via gas chromatography with an electron capture detector (GC-ECD). Several optimization experiments were performed for the sample pretreatment step to establish a more sensitive and efficient analysis scheme. The method was tested in terms of linearity, accuracy, precision, and detection limits. The linear range of the method was 0.1-100 μg L-1, with recovery rates from blank matrix-spiked samples ranging from 84.9% to 122.6%, relative standard deviations between 1.7% and 14.2%, detection limits from 0.013 to 0.3 μg L-1, and quantitation limits from 0.043 to 1.0 μg L-1. Finally, the method was applied to detect HAAs in actual human urine samples. Six HAAs were detected in 460 urine samples to varying degrees, with geometric mean concentrations ranging from 0.07 to 0.89 μg L-1. The results demonstrate that the method is practical, and suitable for routine biomonitoring of HAAs in populations.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信