Bridging the Gap: Eco-Friendly HPLC Analysis of Metformin and Lobeglitazone Sulfate Despite Polarity and Dosage Differences

IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Honey Kevat, Ayushi Prajapati, Kiran Parmar, Bhumika Maheriya, Hardi Joshi, Jigna Vadalia, Kashyap Thummar
{"title":"Bridging the Gap: Eco-Friendly HPLC Analysis of Metformin and Lobeglitazone Sulfate Despite Polarity and Dosage Differences","authors":"Honey Kevat,&nbsp;Ayushi Prajapati,&nbsp;Kiran Parmar,&nbsp;Bhumika Maheriya,&nbsp;Hardi Joshi,&nbsp;Jigna Vadalia,&nbsp;Kashyap Thummar","doi":"10.1002/bmc.70013","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>A precise and stability-indicating high-performance liquid chromatographic (HPLC) method was developed and validated for the simultaneous estimation of lobeglitazone sulfate (0.5 mg) and metformin hydrochloride (500 mg) in pharmaceutical formulations. This method effectively addresses the analytical challenge posed by the significantly different dosage strengths and contrasting polarities of lobeglitazone (water insoluble) and metformin (water soluble). Utilizing a Phenomenex Strong Cation Exchange (250 mm × 4.6 mm, 10 μm) column, the method employed a mobile phase of ammonium dihydrogen phosphate (pH 3.0) and a premix of methanol and acetonitrile (80:20), delivered at a flow rate of 1.0 mL/min. The PDA detector was set at 251 nm to monitor eluents, and the column temperature was maintained at 30°C for optimal separation. The method was validated as per ICH guidelines, covering specificity, linearity, accuracy, precision, LOD, LOQ, solution stability, and robustness. Forced degradation studies under various stress conditions (acidic, basic, oxidative, photolytic, and thermal) revealed no significant degradation products. The method was also assessed for greenness using a AGREE tool, achieving a score of 0.68, demonstrating its eco-friendly nature. Overall, this method is suitable for the routine analysis of these drugs in pharmaceutical formulations.</p>\n </div>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 3","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70013","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

A precise and stability-indicating high-performance liquid chromatographic (HPLC) method was developed and validated for the simultaneous estimation of lobeglitazone sulfate (0.5 mg) and metformin hydrochloride (500 mg) in pharmaceutical formulations. This method effectively addresses the analytical challenge posed by the significantly different dosage strengths and contrasting polarities of lobeglitazone (water insoluble) and metformin (water soluble). Utilizing a Phenomenex Strong Cation Exchange (250 mm × 4.6 mm, 10 μm) column, the method employed a mobile phase of ammonium dihydrogen phosphate (pH 3.0) and a premix of methanol and acetonitrile (80:20), delivered at a flow rate of 1.0 mL/min. The PDA detector was set at 251 nm to monitor eluents, and the column temperature was maintained at 30°C for optimal separation. The method was validated as per ICH guidelines, covering specificity, linearity, accuracy, precision, LOD, LOQ, solution stability, and robustness. Forced degradation studies under various stress conditions (acidic, basic, oxidative, photolytic, and thermal) revealed no significant degradation products. The method was also assessed for greenness using a AGREE tool, achieving a score of 0.68, demonstrating its eco-friendly nature. Overall, this method is suitable for the routine analysis of these drugs in pharmaceutical formulations.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信