4-D Vector Doppler Imaging Using Row-Column Addressed Array

IF 3 2区 工程技术 Q1 ACOUSTICS
Qiandong Sun;Yapeng Fu;Shaoyuan Yan;Kailiang Xu
{"title":"4-D Vector Doppler Imaging Using Row-Column Addressed Array","authors":"Qiandong Sun;Yapeng Fu;Shaoyuan Yan;Kailiang Xu","doi":"10.1109/TUFFC.2024.3519179","DOIUrl":null,"url":null,"abstract":"Large aperture 4-D blood flow Doppler imaging with high temporal resolution remains an important challenge. Different from the conventional matrix-array strategy, we proposed a 4-D ultrasound vector Doppler (4D-UVD) imaging method using a <inline-formula> <tex-math>$128+128$ </tex-math></inline-formula> row-column addressed (RCA) array and a 256-channel ultrasound platform. This method integrates ultrafast 2-D plane wave transmission sequence and least-squares multiangle Doppler velocity estimator. The accuracy of the proposed method was evaluated in both simulations and phantom experiments of parabolic flow. The simulated result shows that the root-mean-squared error (RMSE) of estimated velocity is less than 15%. In the phantom experiments, the relative mean bias <inline-formula> <tex-math>$\\overline {B}$ </tex-math></inline-formula> and the standard deviation (SD) <inline-formula> <tex-math>$\\overline {\\sigma }$ </tex-math></inline-formula> of the velocity profiles are less than 7.9% and 6.9%, respectively, suggesting a high estimated precision. Furthermore, in vivo feasibility of the approach was demonstrated in the human carotid artery. The blood flow velocity of the carotid artery was continuously measured over seven cardiac cycles at a 1-kHz volume rate. The fluctuations of the estimated mean and peak velocities were highly consistent with the pulse waves measured using a gating pulse sensor, yielding synchronization coefficients of 0.85 and 0.87, respectively. It is thus concluded that the proposed method can achieve a large aperture 4-D vector flow imaging with high temporal resolution using an RCA probe.","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"72 2","pages":"202-214"},"PeriodicalIF":3.0000,"publicationDate":"2024-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10804860/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Large aperture 4-D blood flow Doppler imaging with high temporal resolution remains an important challenge. Different from the conventional matrix-array strategy, we proposed a 4-D ultrasound vector Doppler (4D-UVD) imaging method using a $128+128$ row-column addressed (RCA) array and a 256-channel ultrasound platform. This method integrates ultrafast 2-D plane wave transmission sequence and least-squares multiangle Doppler velocity estimator. The accuracy of the proposed method was evaluated in both simulations and phantom experiments of parabolic flow. The simulated result shows that the root-mean-squared error (RMSE) of estimated velocity is less than 15%. In the phantom experiments, the relative mean bias $\overline {B}$ and the standard deviation (SD) $\overline {\sigma }$ of the velocity profiles are less than 7.9% and 6.9%, respectively, suggesting a high estimated precision. Furthermore, in vivo feasibility of the approach was demonstrated in the human carotid artery. The blood flow velocity of the carotid artery was continuously measured over seven cardiac cycles at a 1-kHz volume rate. The fluctuations of the estimated mean and peak velocities were highly consistent with the pulse waves measured using a gating pulse sensor, yielding synchronization coefficients of 0.85 and 0.87, respectively. It is thus concluded that the proposed method can achieve a large aperture 4-D vector flow imaging with high temporal resolution using an RCA probe.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信