A new VCG signal compression technique based on discrete Karhunen-Loeve expansion and tunable quality wavelet transform

IF 1.3 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Ronak Vimal, A. Kumar, Aditya Tiwari
{"title":"A new VCG signal compression technique based on discrete Karhunen-Loeve expansion and tunable quality wavelet transform","authors":"Ronak Vimal,&nbsp;A. Kumar,&nbsp;Aditya Tiwari","doi":"10.1016/j.jelectrocard.2025.153894","DOIUrl":null,"url":null,"abstract":"<div><div>This paper presents a novel two-stage compression technique for vectorcardiogram (VCG) signals, combining Discrete Karhunen-Loeve (K-L) Expansion and Tunable Q-Factor Wavelet Transform (TQWT). In the first stage, VCG signals undergo discrete K-L expansion and a secondary rotation to reduce variance caused by physiological factors, such as respiration and varying heart orientations among patients. This process effectively simplifies the dataset by leveraging eigenvector-based transformation, while standardizing the data across different VCG records. In the second stage, the standardized data is processed using TQWT, with finely tuned parameters (Q-factor of 4, redundancy factor of 1.2, and 6 stages), followed by quantization and Run-Length Encoding (RLE). The RLE method efficiently compresses the long sequences of zeros generated during the process, further enhancing the data reduction. The proposed method was rigorously evaluated using the PTB Diagnostic ECG Database, demonstrating remarkable compression efficiency. When compared with standard approaches like Discrete K-L Transform and Discrete Cosine Transform (DCT), the method achieved a superior average compression ratio of 15.43. Key evaluation metrics further highlight its efficacy, including an average Percent Root Difference (PRD) of 7.39 %, Fidelity of 99.72 %, Peak Signal-to-Noise Ratio (PSNR) of 37.38 dB, and a Quality Score (QS) of 2.13 %. Moreover, the method's rapid processing speed of 0.076 s per record makes it well-suited for real-time applications. This innovative approach provides an effective solution for VCG signal compression, enhancing the storage and transmission efficiency, while preserving high signal fidelity for clinical use.</div></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":"89 ","pages":"Article 153894"},"PeriodicalIF":1.3000,"publicationDate":"2025-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073625000226","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a novel two-stage compression technique for vectorcardiogram (VCG) signals, combining Discrete Karhunen-Loeve (K-L) Expansion and Tunable Q-Factor Wavelet Transform (TQWT). In the first stage, VCG signals undergo discrete K-L expansion and a secondary rotation to reduce variance caused by physiological factors, such as respiration and varying heart orientations among patients. This process effectively simplifies the dataset by leveraging eigenvector-based transformation, while standardizing the data across different VCG records. In the second stage, the standardized data is processed using TQWT, with finely tuned parameters (Q-factor of 4, redundancy factor of 1.2, and 6 stages), followed by quantization and Run-Length Encoding (RLE). The RLE method efficiently compresses the long sequences of zeros generated during the process, further enhancing the data reduction. The proposed method was rigorously evaluated using the PTB Diagnostic ECG Database, demonstrating remarkable compression efficiency. When compared with standard approaches like Discrete K-L Transform and Discrete Cosine Transform (DCT), the method achieved a superior average compression ratio of 15.43. Key evaluation metrics further highlight its efficacy, including an average Percent Root Difference (PRD) of 7.39 %, Fidelity of 99.72 %, Peak Signal-to-Noise Ratio (PSNR) of 37.38 dB, and a Quality Score (QS) of 2.13 %. Moreover, the method's rapid processing speed of 0.076 s per record makes it well-suited for real-time applications. This innovative approach provides an effective solution for VCG signal compression, enhancing the storage and transmission efficiency, while preserving high signal fidelity for clinical use.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of electrocardiology
Journal of electrocardiology 医学-心血管系统
CiteScore
2.70
自引率
7.70%
发文量
152
审稿时长
38 days
期刊介绍: The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信