Evaluation of the Effect of Nanosilver and Bismuth oxide on the Radiopacity of a Novel Hydraulic Calcium Silicate-based Endodontic Sealer: An In vitro Study.

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Medical Physics Pub Date : 2024-10-01 Epub Date: 2024-12-18 DOI:10.4103/jmp.jmp_158_24
Teena Sheethal Dsouza, Aditya Shetty, Kelvin Peter Pais, Meenakumari Chikkanna, Fahad Hamoud Almutairi, Yazeed Abdulaziz Alharbi, J Suresh Babu, C Swarnalatha, Abhishek Singh Nayyar
{"title":"Evaluation of the Effect of Nanosilver and Bismuth oxide on the Radiopacity of a Novel Hydraulic Calcium Silicate-based Endodontic Sealer: An <i>In vitro</i> Study.","authors":"Teena Sheethal Dsouza, Aditya Shetty, Kelvin Peter Pais, Meenakumari Chikkanna, Fahad Hamoud Almutairi, Yazeed Abdulaziz Alharbi, J Suresh Babu, C Swarnalatha, Abhishek Singh Nayyar","doi":"10.4103/jmp.jmp_158_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aim: </strong>A wide range of dental materials have incorporated the concept of nanotechnology into their composition to enhance their physical and antimicrobial properties. In this pretext, silver nanoparticles (AgNPs) are among the most commonly used nanoparticles which are exceptionally noteworthy for their role in medical applications as an antibacterial agent. Another essential, desirable physical characteristic of all endodontic cements is their radiopacity, while in similar context, various radiopacifying agents such as bismuth oxide, barium sulfate, and even AgNPs have been incorporated in endodontic sealers to enhance their physical properties. The aim of the present study was to assess whether the incorporation of AgNPs and 10% bismuth oxide imparted the required radiopacity to the novel cement material (Nano CS) as per the requirement and standards laid by the International Organization for Standardization (ISO) guidelines and whether it complied with the ISO 6876:2001 specifications to achieve the necessary norms.</p><p><strong>Materials and methods: </strong>The structural characteristics of the novel cement material (Nano CS) were observed using energy-dispersive X-ray analysis under a Zeiss Gemini 500 Field Emission Scanning Electron Microscope, while radiopacity of the test material (Nano CS) was assessed with the help of an aluminum (Al) step-wedge using a nondestructive testing method following ISO guidelines. The optical density of the test material (Nano CS) was tested with the specimens of mineral trioxide aggregate (MTA) as the standard cement material along with the specimens of enamel and dentin that were 1 mm thick, and Al of appropriate thickness with the desired and equivalent radiopacity.</p><p><strong>Results: </strong>The findings of the present study suggested MTA to have higher radiopacity index equivalent to 4.56 ± 0.00 mm thickness of Al when compared to the test material (Nano CS) (2.78 ± 0.01 mm thickness of Al) and enamel (4.09 ± 0.01 mm thickness of Al) and dentin (2.01 ± 0.01 mm thickness of Al) specimens. Furthermore, the radiopacity index of test material (Nano CS) was found to be more when compared to dentin, though, less when compared to the enamel specimens with the results being statistically highly significant (<i>P</i> < 0.001).</p><p><strong>Conclusion: </strong>The addition of nanosilver and bismuth oxide to the test material (Nano CS) imparted characteristic radiopacity, though the required specifications laid down by the ISO standards were not achieved. Increasing the concentration of the additives used might be considered to bring in the required radiopacity without having a significant impact on the physical and biological properties of the test material (Nano CS) intended to be used for endodontic applications.</p>","PeriodicalId":51719,"journal":{"name":"Journal of Medical Physics","volume":"49 4","pages":"642-647"},"PeriodicalIF":0.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11801090/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jmp.jmp_158_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/18 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aim: A wide range of dental materials have incorporated the concept of nanotechnology into their composition to enhance their physical and antimicrobial properties. In this pretext, silver nanoparticles (AgNPs) are among the most commonly used nanoparticles which are exceptionally noteworthy for their role in medical applications as an antibacterial agent. Another essential, desirable physical characteristic of all endodontic cements is their radiopacity, while in similar context, various radiopacifying agents such as bismuth oxide, barium sulfate, and even AgNPs have been incorporated in endodontic sealers to enhance their physical properties. The aim of the present study was to assess whether the incorporation of AgNPs and 10% bismuth oxide imparted the required radiopacity to the novel cement material (Nano CS) as per the requirement and standards laid by the International Organization for Standardization (ISO) guidelines and whether it complied with the ISO 6876:2001 specifications to achieve the necessary norms.

Materials and methods: The structural characteristics of the novel cement material (Nano CS) were observed using energy-dispersive X-ray analysis under a Zeiss Gemini 500 Field Emission Scanning Electron Microscope, while radiopacity of the test material (Nano CS) was assessed with the help of an aluminum (Al) step-wedge using a nondestructive testing method following ISO guidelines. The optical density of the test material (Nano CS) was tested with the specimens of mineral trioxide aggregate (MTA) as the standard cement material along with the specimens of enamel and dentin that were 1 mm thick, and Al of appropriate thickness with the desired and equivalent radiopacity.

Results: The findings of the present study suggested MTA to have higher radiopacity index equivalent to 4.56 ± 0.00 mm thickness of Al when compared to the test material (Nano CS) (2.78 ± 0.01 mm thickness of Al) and enamel (4.09 ± 0.01 mm thickness of Al) and dentin (2.01 ± 0.01 mm thickness of Al) specimens. Furthermore, the radiopacity index of test material (Nano CS) was found to be more when compared to dentin, though, less when compared to the enamel specimens with the results being statistically highly significant (P < 0.001).

Conclusion: The addition of nanosilver and bismuth oxide to the test material (Nano CS) imparted characteristic radiopacity, though the required specifications laid down by the ISO standards were not achieved. Increasing the concentration of the additives used might be considered to bring in the required radiopacity without having a significant impact on the physical and biological properties of the test material (Nano CS) intended to be used for endodontic applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Physics
Journal of Medical Physics RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.10
自引率
11.10%
发文量
55
审稿时长
30 weeks
期刊介绍: JOURNAL OF MEDICAL PHYSICS is the official journal of Association of Medical Physicists of India (AMPI). The association has been bringing out a quarterly publication since 1976. Till the end of 1993, it was known as Medical Physics Bulletin, which then became Journal of Medical Physics. The main objective of the Journal is to serve as a vehicle of communication to highlight all aspects of the practice of medical radiation physics. The areas covered include all aspects of the application of radiation physics to biological sciences, radiotherapy, radiodiagnosis, nuclear medicine, dosimetry and radiation protection. Papers / manuscripts dealing with the aspects of physics related to cancer therapy / radiobiology also fall within the scope of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信