{"title":"Assessment of the Hardness of Various Orthodontic Wires.","authors":"Yohan Verghese, Kumar Gaurav, Guneet Kour, Geetika Tomer, Subhrajeet Narayan Sahoo, Snigdha Pattanaik, Azhar Mohammed","doi":"10.4103/jpbs.jpbs_776_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The mechanical characteristics of orthodontic wires are crucial since they have a significant impact on the effectiveness of orthodontic therapy, and patients undergoing orthodontic treatment are becoming more and more picky about their aesthetic preferences.</p><p><strong>Objectives: </strong>The goal of the current investigation was to assess the hardness of various orthodontic wires.</p><p><strong>Materials and methods: </strong>Three types of wires were employed in this study: nickel titanium (NiTi, USA), beta-titanium (TMA, USA), and stainless steel (SS, Germany). For the upper left canine in this investigation, we utilized an edgewise bracket with a slot size of 0.018″. Epoxy resin was used to implant the wires. The orientation of the brackets was horizontal. Next, a measurement was taken of the brackets' external surfaces' hardness. Using an optical microscope, the micrographs of the typical Vickers indentations were captured. The acquired data was assessed statistically.</p><p><strong>Results: </strong>The specimens belonging to the stainless steel, nickel-titanium, and beta-titanium groups had mean microhardness values of 523.24, 367.22, and 321.36, respectively. There were noteworthy outcomes when comparing the three research groups.</p><p><strong>Conclusion: </strong>Among the stainless steel group specimens, the highest microhardness was observed. However, more research is advised.</p>","PeriodicalId":94339,"journal":{"name":"Journal of pharmacy & bioallied sciences","volume":"16 Suppl 4","pages":"S3254-S3256"},"PeriodicalIF":0.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11805290/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacy & bioallied sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jpbs.jpbs_776_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/13 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The mechanical characteristics of orthodontic wires are crucial since they have a significant impact on the effectiveness of orthodontic therapy, and patients undergoing orthodontic treatment are becoming more and more picky about their aesthetic preferences.

Objectives: The goal of the current investigation was to assess the hardness of various orthodontic wires.

Materials and methods: Three types of wires were employed in this study: nickel titanium (NiTi, USA), beta-titanium (TMA, USA), and stainless steel (SS, Germany). For the upper left canine in this investigation, we utilized an edgewise bracket with a slot size of 0.018″. Epoxy resin was used to implant the wires. The orientation of the brackets was horizontal. Next, a measurement was taken of the brackets' external surfaces' hardness. Using an optical microscope, the micrographs of the typical Vickers indentations were captured. The acquired data was assessed statistically.

Results: The specimens belonging to the stainless steel, nickel-titanium, and beta-titanium groups had mean microhardness values of 523.24, 367.22, and 321.36, respectively. There were noteworthy outcomes when comparing the three research groups.

Conclusion: Among the stainless steel group specimens, the highest microhardness was observed. However, more research is advised.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信