{"title":"Monte Carlo Simulation of Gamma and Neutron Shielding with High-performance Ultra-heavy Cement Composite.","authors":"Mohammadreza Alipoor, Mahdi Eshghi, Ramazan Sever","doi":"10.4103/jmp.jmp_91_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>As the applications of nuclear technology increase in today's world, radiation protection becomes even more important. Radiation protection is important in medical imaging applications and radiotherapy rooms. Therefore, in this research, we have investigated features of the ionizing radiation shielding of the modified cement composite with iron, strontium, zinc, and zirconium elements in the photon energy range of 15 keV to 10 MeV.</p><p><strong>Materials and methods: </strong>To extract such features, it is necessary to use a computational method. In this research, we have done all our calculations based on the Geant4 tool based on the Monte Carlo method. This tool is a multipurpose tool that can be used for particle transport calculations such as electrons, protons, neutrons, heavy charged particles, and photons in different environments such as human tissues.</p><p><strong>Results: </strong>The mass attenuation coefficient of the samples was calculated using the Geant4 Monte Carlo simulation tool and compared with the results of the Phy-X program, which was in good agreement. To evaluate the radiation shielding capabilities, other quantities such as the linear attenuation coefficient, the thickness of the tenth value layer, the thermal neutron cross-section, absorption rate of thermal neutrons, and the cross-section of the fast neutron removal are determined.</p><p><strong>Conclusions: </strong>According to the quantitative results, cement composite is more effective in absorbing and weakening gamma and neutrons. Calculations of radiation shielding quantities show that cement composites containing tungsten carbide and thallium oxide waste powder are a suitable combination and a practical material for radiation control. In addition, by returning industrial waste to the production sector, they will also be effective in reducing environmental pollution. In general, the cement composite sample containing iron, thallium, zinc, zirconium, tungsten, and carbon elements shows a high potential for radiation protection applications. This study highlights the effective radiation shielding potential of cementitious composites and demonstrates the importance of advancing safety measures in medical and industrial radiation applications.</p>","PeriodicalId":51719,"journal":{"name":"Journal of Medical Physics","volume":"49 4","pages":"661-672"},"PeriodicalIF":0.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11801086/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jmp.jmp_91_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/18 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: As the applications of nuclear technology increase in today's world, radiation protection becomes even more important. Radiation protection is important in medical imaging applications and radiotherapy rooms. Therefore, in this research, we have investigated features of the ionizing radiation shielding of the modified cement composite with iron, strontium, zinc, and zirconium elements in the photon energy range of 15 keV to 10 MeV.

Materials and methods: To extract such features, it is necessary to use a computational method. In this research, we have done all our calculations based on the Geant4 tool based on the Monte Carlo method. This tool is a multipurpose tool that can be used for particle transport calculations such as electrons, protons, neutrons, heavy charged particles, and photons in different environments such as human tissues.

Results: The mass attenuation coefficient of the samples was calculated using the Geant4 Monte Carlo simulation tool and compared with the results of the Phy-X program, which was in good agreement. To evaluate the radiation shielding capabilities, other quantities such as the linear attenuation coefficient, the thickness of the tenth value layer, the thermal neutron cross-section, absorption rate of thermal neutrons, and the cross-section of the fast neutron removal are determined.

Conclusions: According to the quantitative results, cement composite is more effective in absorbing and weakening gamma and neutrons. Calculations of radiation shielding quantities show that cement composites containing tungsten carbide and thallium oxide waste powder are a suitable combination and a practical material for radiation control. In addition, by returning industrial waste to the production sector, they will also be effective in reducing environmental pollution. In general, the cement composite sample containing iron, thallium, zinc, zirconium, tungsten, and carbon elements shows a high potential for radiation protection applications. This study highlights the effective radiation shielding potential of cementitious composites and demonstrates the importance of advancing safety measures in medical and industrial radiation applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Physics
Journal of Medical Physics RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.10
自引率
11.10%
发文量
55
审稿时长
30 weeks
期刊介绍: JOURNAL OF MEDICAL PHYSICS is the official journal of Association of Medical Physicists of India (AMPI). The association has been bringing out a quarterly publication since 1976. Till the end of 1993, it was known as Medical Physics Bulletin, which then became Journal of Medical Physics. The main objective of the Journal is to serve as a vehicle of communication to highlight all aspects of the practice of medical radiation physics. The areas covered include all aspects of the application of radiation physics to biological sciences, radiotherapy, radiodiagnosis, nuclear medicine, dosimetry and radiation protection. Papers / manuscripts dealing with the aspects of physics related to cancer therapy / radiobiology also fall within the scope of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信