{"title":"Waveform characteristics in thoracic paravertebral space: a prospective observational study.","authors":"Amorn Vijitpavan, Sivaporn Termpornlert, Pattika Subsoontorn, Lalinthip Vareesunthorn","doi":"10.12688/f1000research.139904.2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With increased use of thoracic paravertebral block (TPVB) in thoracic surgery, many faced the challenge of locating the thoracic paravertebral space (TPVS) ultrasonographically. This observational study aimed to investigate the waveform characteristics and pressure value within the TPVS in anaesthetized patients with controlled ventilation.</p><p><strong>Methods: </strong>50 patients scheduled for elective lung surgery were enrolled. After conduction of anesthesia, all patients underwent TPVB at T4/5 and T6/7 using transverse, in-plane ultrasound guidance. A pressure transducer system with a desktop monitor was connected to the needle hub to measure pressure values and waveform characteristics in three locations: the paraspinal muscles, immediately behind the superior costotransverse ligament, and within the TPVS. Next, 15 mL of 0.33% bupivacaine was injected into each desired TPVS. After completion of the surgery, the extent of dermatomal blockade and the pain score was assessed in all patients.</p><p><strong>Results: </strong>98 typical regular respiratory waveforms with a mean pressure of ≤ 25 mmHg were detected in the TPVS of 50 patients. The sensitivity of the combined ultrasound and pressure waveform measurement technique to identify the TPVS was 95.45% (95% confidence interval, 84.527-99.445). Nontypical respiratory waveforms were present in two patients. Factors interfering with the TPVS waveform characteristics were previous thoracic surgery.</p><p><strong>Conclusion: </strong>The TPVS had low pressure and showed a smooth, regular waveform pattern corresponding to respiration.</p>","PeriodicalId":12260,"journal":{"name":"F1000Research","volume":"13 ","pages":"150"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11807241/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"F1000Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12688/f1000research.139904.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0
Abstract
Background: With increased use of thoracic paravertebral block (TPVB) in thoracic surgery, many faced the challenge of locating the thoracic paravertebral space (TPVS) ultrasonographically. This observational study aimed to investigate the waveform characteristics and pressure value within the TPVS in anaesthetized patients with controlled ventilation.
Methods: 50 patients scheduled for elective lung surgery were enrolled. After conduction of anesthesia, all patients underwent TPVB at T4/5 and T6/7 using transverse, in-plane ultrasound guidance. A pressure transducer system with a desktop monitor was connected to the needle hub to measure pressure values and waveform characteristics in three locations: the paraspinal muscles, immediately behind the superior costotransverse ligament, and within the TPVS. Next, 15 mL of 0.33% bupivacaine was injected into each desired TPVS. After completion of the surgery, the extent of dermatomal blockade and the pain score was assessed in all patients.
Results: 98 typical regular respiratory waveforms with a mean pressure of ≤ 25 mmHg were detected in the TPVS of 50 patients. The sensitivity of the combined ultrasound and pressure waveform measurement technique to identify the TPVS was 95.45% (95% confidence interval, 84.527-99.445). Nontypical respiratory waveforms were present in two patients. Factors interfering with the TPVS waveform characteristics were previous thoracic surgery.
Conclusion: The TPVS had low pressure and showed a smooth, regular waveform pattern corresponding to respiration.
F1000ResearchPharmacology, Toxicology and Pharmaceutics-Pharmacology, Toxicology and Pharmaceutics (all)
CiteScore
5.00
自引率
0.00%
发文量
1646
审稿时长
1 weeks
期刊介绍:
F1000Research publishes articles and other research outputs reporting basic scientific, scholarly, translational and clinical research across the physical and life sciences, engineering, medicine, social sciences and humanities. F1000Research is a scholarly publication platform set up for the scientific, scholarly and medical research community; each article has at least one author who is a qualified researcher, scholar or clinician actively working in their speciality and who has made a key contribution to the article. Articles must be original (not duplications). All research is suitable irrespective of the perceived level of interest or novelty; we welcome confirmatory and negative results, as well as null studies. F1000Research publishes different type of research, including clinical trials, systematic reviews, software tools, method articles, and many others. Reviews and Opinion articles providing a balanced and comprehensive overview of the latest discoveries in a particular field, or presenting a personal perspective on recent developments, are also welcome. See the full list of article types we accept for more information.