Mn3O4 Tetrahedral with Carbonyldiimidazole Nanoflower Deposition on Laser-Scribed Graphene for Selective Bio-Capture.

IF 3.2 4区 生物学 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
Sivainesh Devi Remesh, Jeysree Chelvaraj, Veeradasan Perumal, Subash C B Gopinath, Mark Ovinis, Saravanan Karupannan, Natarajan Arumugam, Raju Suresh Kumar
{"title":"Mn<sub>3</sub>O<sub>4</sub> Tetrahedral with Carbonyldiimidazole Nanoflower Deposition on Laser-Scribed Graphene for Selective Bio-Capture.","authors":"Sivainesh Devi Remesh, Jeysree Chelvaraj, Veeradasan Perumal, Subash C B Gopinath, Mark Ovinis, Saravanan Karupannan, Natarajan Arumugam, Raju Suresh Kumar","doi":"10.1002/bab.2731","DOIUrl":null,"url":null,"abstract":"<p><p>Dengue fever, a mosquito-borne viral infection, poses a significant global health challenge, particularly in tropical and subtropical regions. The absence of non-effective vaccines and specific treatments underscores the need for advanced diagnostic tools for early detection and management. This study presents a novel biosensor for detecting dengue virus type 4 (DENV-4) by combining carbonyldiimidazole nanoflower (CDI-NF) with Mn<sub>3</sub>O<sub>4</sub> on laser-scribed graphene (LSG). Material characterization techniques, including Raman spectroscopy, TEM, XRD, XPS, and FTIR, were employed to confirm the successful integration of Mn<sub>3</sub>O<sub>4</sub> and CDI-NF, resulting in a unique 3D flower-like structure. In order to verify the sensing efficiency, a selective DNA sample captured on LSG/Mn<sub>3</sub>O<sub>4</sub>-CDI-NF was investigated for specifc binding with Aedes aegypti target DNA through selective hybridization and mismatch analysis. Electrochemical impedance studies further confirmed sensitive detection of up to 1 fM, where the sensitivity was confirmed by large transfer resistance (R<sub>ct</sub>) before and after hybridization with a regression coefficient 0.97373. EIS results demonstrated successful surface modifications and the biosensor's specificity in distinguishing between complementary, mismatched, and non-complementary target sequences. The biosensor's ability to differentiate between these sequences highlights its potential for accurate and targeted DENV-4 detection, offering a promising avenue for advancing dengue diagnostics.</p>","PeriodicalId":9274,"journal":{"name":"Biotechnology and applied biochemistry","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology and applied biochemistry","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/bab.2731","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Dengue fever, a mosquito-borne viral infection, poses a significant global health challenge, particularly in tropical and subtropical regions. The absence of non-effective vaccines and specific treatments underscores the need for advanced diagnostic tools for early detection and management. This study presents a novel biosensor for detecting dengue virus type 4 (DENV-4) by combining carbonyldiimidazole nanoflower (CDI-NF) with Mn3O4 on laser-scribed graphene (LSG). Material characterization techniques, including Raman spectroscopy, TEM, XRD, XPS, and FTIR, were employed to confirm the successful integration of Mn3O4 and CDI-NF, resulting in a unique 3D flower-like structure. In order to verify the sensing efficiency, a selective DNA sample captured on LSG/Mn3O4-CDI-NF was investigated for specifc binding with Aedes aegypti target DNA through selective hybridization and mismatch analysis. Electrochemical impedance studies further confirmed sensitive detection of up to 1 fM, where the sensitivity was confirmed by large transfer resistance (Rct) before and after hybridization with a regression coefficient 0.97373. EIS results demonstrated successful surface modifications and the biosensor's specificity in distinguishing between complementary, mismatched, and non-complementary target sequences. The biosensor's ability to differentiate between these sequences highlights its potential for accurate and targeted DENV-4 detection, offering a promising avenue for advancing dengue diagnostics.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biotechnology and applied biochemistry
Biotechnology and applied biochemistry 工程技术-生化与分子生物学
CiteScore
6.00
自引率
7.10%
发文量
117
审稿时长
3 months
期刊介绍: Published since 1979, Biotechnology and Applied Biochemistry is dedicated to the rapid publication of high quality, significant research at the interface between life sciences and their technological exploitation. The Editors will consider papers for publication based on their novelty and impact as well as their contribution to the advancement of medical biotechnology and industrial biotechnology, covering cutting-edge research in synthetic biology, systems biology, metabolic engineering, bioengineering, biomaterials, biosensing, and nano-biotechnology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信