Xi Wu, Chenggang Geng, Weiwei Cheng, Zhenjiong Wang, Yan Zhang, Di Wu, Xiaozhi Tang
{"title":"An ultrasensitive homogeneous electrochemical strategy for ochratoxin a sensing based on nanoscale PCN-224@MB@Apt.","authors":"Xi Wu, Chenggang Geng, Weiwei Cheng, Zhenjiong Wang, Yan Zhang, Di Wu, Xiaozhi Tang","doi":"10.1016/j.talanta.2025.127695","DOIUrl":null,"url":null,"abstract":"<p><p>In this reasearch, a homogeneous electrochemical sensor based on PCN-224@MB@Apt was fabricated for the ultrasensitive determination of ochratoxin A (OTA). Firstly, nanoscale PCN-224 were synthesized as the nanocarrier to embed the signal probe of methylene blue (MB). Then, the OTA aptamer (Apt) was added and connected to PCN-224@MB via the Zr-O-P bond between Zr metal sites of PCN-224 and phosphate group of Apt as the biogate. When OTA exists, the Apt would preferentially bind with OTA and fall off from PCN-224@MB, leading to the release of MB and generation of differential pulse voltammetry (DPV) response. The DPV response of MB was linearly correlated with the amount of OTA. The optimized PCN-224@MB@Apt sensor showed outstanding detection performance towards OTA with a low detection limit of 2.6 × 10<sup>-5</sup> ng/mL (S/N = 3) and wide linear range (10<sup>-4</sup>-10 ng/mL). Meanwhile, the fabricated homogeneous electrochemical sensor exhibited splendid stability, reproducibility, and specificity. To assess the practical applicability, the PCN-224@MB@Apt sensor was applied to detect OTA in real corn samples and desirable recovery rates varying from 83.2 % to 109.6 % were obtained.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"287 ","pages":"127695"},"PeriodicalIF":5.6000,"publicationDate":"2025-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2025.127695","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
In this reasearch, a homogeneous electrochemical sensor based on PCN-224@MB@Apt was fabricated for the ultrasensitive determination of ochratoxin A (OTA). Firstly, nanoscale PCN-224 were synthesized as the nanocarrier to embed the signal probe of methylene blue (MB). Then, the OTA aptamer (Apt) was added and connected to PCN-224@MB via the Zr-O-P bond between Zr metal sites of PCN-224 and phosphate group of Apt as the biogate. When OTA exists, the Apt would preferentially bind with OTA and fall off from PCN-224@MB, leading to the release of MB and generation of differential pulse voltammetry (DPV) response. The DPV response of MB was linearly correlated with the amount of OTA. The optimized PCN-224@MB@Apt sensor showed outstanding detection performance towards OTA with a low detection limit of 2.6 × 10-5 ng/mL (S/N = 3) and wide linear range (10-4-10 ng/mL). Meanwhile, the fabricated homogeneous electrochemical sensor exhibited splendid stability, reproducibility, and specificity. To assess the practical applicability, the PCN-224@MB@Apt sensor was applied to detect OTA in real corn samples and desirable recovery rates varying from 83.2 % to 109.6 % were obtained.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.