{"title":"Effects of Thermal Performance Enhancement on PTC Downsizing With Emphasis on Cost Savings and Commercial Feasibility: An Extended Evaluation Criterion","authors":"Nabil Bessanane,&nbsp;Yassine Demagh,&nbsp;Mohamed Si-ameur,&nbsp;Mourad Rebay","doi":"10.1002/htj.23174","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>This study proposes a new comparative analysis and introduces a new criterion for evaluating the size reduction of heat exchangers, particularly relevant in the context of parabolic trough receivers. Various innovative receivers from the literature, employing different enhancement techniques, were compared with the conventional straight receiver. On the basis of the principle of similarity and using a previously validated one-dimensional mathematical model and numerical code, a parametric analysis was used to estimate reduction ratios <span></span><math>\n <semantics>\n <mrow>\n \n <mrow>\n <mo>(</mo>\n \n <mi>ζ</mi>\n \n <mo>)</mo>\n </mrow>\n </mrow>\n <annotation> &lt;math altimg=\"urn:x-wiley:26884534:media:htj23174:htj23174-math-0001\" wiley:location=\"equation/htj23174-math-0001.png\" display=\"inline\" xmlns=\"http://www.w3.org/1998/Math/MathML\"&gt;&lt;mrow&gt;&lt;mrow&gt;&lt;mo&gt;(&lt;/mo&gt;&lt;mi&gt;\\unicode{x003B6}&lt;/mi&gt;&lt;mo&gt;)&lt;/mo&gt;&lt;/mrow&gt;&lt;/mrow&gt;&lt;/math&gt;</annotation>\n </semantics></math> and sizes for different solar receivers. For well-defined receiver geometries, the main results reveal consistent reduction ratios of around 99.7% and 93.53% for helical screw-tape and wavy receivers, respectively. This translates to size reductions of approximately 0.3 and 6.5 m compared with a 100-m-long conventional straight receiver, respectively. By integrating the <span></span><math>\n <semantics>\n <mrow>\n \n <mrow>\n <mi>ζ</mi>\n </mrow>\n </mrow>\n <annotation> &lt;math altimg=\"urn:x-wiley:26884534:media:htj23174:htj23174-math-0002\" wiley:location=\"equation/htj23174-math-0002.png\" display=\"inline\" xmlns=\"http://www.w3.org/1998/Math/MathML\"&gt;&lt;mrow&gt;&lt;mrow&gt;&lt;mi&gt;\\unicode{x003B6}&lt;/mi&gt;&lt;/mrow&gt;&lt;/mrow&gt;&lt;/math&gt;</annotation>\n </semantics></math> ratio and the performance evaluation criterion (PEC) into a unified metric mPEC = PEC/<span></span><math>\n <semantics>\n <mrow>\n \n <mrow>\n <msup>\n <mi>ζ</mi>\n \n <mn>3</mn>\n </msup>\n </mrow>\n </mrow>\n <annotation> &lt;math altimg=\"urn:x-wiley:26884534:media:htj23174:htj23174-math-0003\" wiley:location=\"equation/htj23174-math-0003.png\" display=\"inline\" xmlns=\"http://www.w3.org/1998/Math/MathML\"&gt;&lt;mrow&gt;&lt;mrow&gt;&lt;msup&gt;&lt;mi&gt;\\unicode{x003B6}&lt;/mi&gt;&lt;mn&gt;3&lt;/mn&gt;&lt;/msup&gt;&lt;/mrow&gt;&lt;/mrow&gt;&lt;/math&gt;</annotation>\n </semantics></math>, which accounts for both effectiveness and size reduction, a new classification of receivers is derived, closely aligning with that obtained by the <span></span><math>\n <semantics>\n <mrow>\n \n <mrow>\n <mi>ζ</mi>\n </mrow>\n </mrow>\n <annotation> &lt;math altimg=\"urn:x-wiley:26884534:media:htj23174:htj23174-math-0004\" wiley:location=\"equation/htj23174-math-0004.png\" display=\"inline\" xmlns=\"http://www.w3.org/1998/Math/MathML\"&gt;&lt;mrow&gt;&lt;mrow&gt;&lt;mi&gt;\\unicode{x003B6}&lt;/mi&gt;&lt;/mrow&gt;&lt;/mrow&gt;&lt;/math&gt;</annotation>\n </semantics></math> ratio. In addition, a rebalancing analysis of the increased load loss is conducted based on this ratio. It suggests that in a scenario where the wavy receiver replaces the conventional straight receiver in operation, there would be no need to increase pumping power, as its reduced size compensates for the increased pressure drop. This scenario was used to assess the economic impact of a parabolic trough collector power plant in Hassi R'mel (Algerian Sahara). Without any additional components to boost performance, the adoption of the wavy receiver led to significant gains in terms of useful surface area, cost, and length, resulting in savings of over €3.02 million for this 30 MW solar energy field.</p>\n </div>","PeriodicalId":44939,"journal":{"name":"Heat Transfer","volume":"54 2","pages":"1331-1349"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heat Transfer","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/htj.23174","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 0

Abstract

This study proposes a new comparative analysis and introduces a new criterion for evaluating the size reduction of heat exchangers, particularly relevant in the context of parabolic trough receivers. Various innovative receivers from the literature, employing different enhancement techniques, were compared with the conventional straight receiver. On the basis of the principle of similarity and using a previously validated one-dimensional mathematical model and numerical code, a parametric analysis was used to estimate reduction ratios ( ζ ) <math altimg="urn:x-wiley:26884534:media:htj23174:htj23174-math-0001" wiley:location="equation/htj23174-math-0001.png" display="inline" xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mrow><mo>(</mo><mi>\unicode{x003B6}</mi><mo>)</mo></mrow></mrow></math> and sizes for different solar receivers. For well-defined receiver geometries, the main results reveal consistent reduction ratios of around 99.7% and 93.53% for helical screw-tape and wavy receivers, respectively. This translates to size reductions of approximately 0.3 and 6.5 m compared with a 100-m-long conventional straight receiver, respectively. By integrating the ζ <math altimg="urn:x-wiley:26884534:media:htj23174:htj23174-math-0002" wiley:location="equation/htj23174-math-0002.png" display="inline" xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mrow><mi>\unicode{x003B6}</mi></mrow></mrow></math> ratio and the performance evaluation criterion (PEC) into a unified metric mPEC = PEC/ ζ 3 <math altimg="urn:x-wiley:26884534:media:htj23174:htj23174-math-0003" wiley:location="equation/htj23174-math-0003.png" display="inline" xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mrow><msup><mi>\unicode{x003B6}</mi><mn>3</mn></msup></mrow></mrow></math> , which accounts for both effectiveness and size reduction, a new classification of receivers is derived, closely aligning with that obtained by the ζ <math altimg="urn:x-wiley:26884534:media:htj23174:htj23174-math-0004" wiley:location="equation/htj23174-math-0004.png" display="inline" xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mrow><mi>\unicode{x003B6}</mi></mrow></mrow></math> ratio. In addition, a rebalancing analysis of the increased load loss is conducted based on this ratio. It suggests that in a scenario where the wavy receiver replaces the conventional straight receiver in operation, there would be no need to increase pumping power, as its reduced size compensates for the increased pressure drop. This scenario was used to assess the economic impact of a parabolic trough collector power plant in Hassi R'mel (Algerian Sahara). Without any additional components to boost performance, the adoption of the wavy receiver led to significant gains in terms of useful surface area, cost, and length, resulting in savings of over €3.02 million for this 30 MW solar energy field.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Heat Transfer
Heat Transfer THERMODYNAMICS-
CiteScore
6.30
自引率
19.40%
发文量
342
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信