Infection control Surveillance of dialysis events at outpatient hemodialysis centers in Saudi Arabia: A 3-year national data

IF 1.8 Q3 INFECTIOUS DISEASES
Mohammed ALQahtani , Aiman El-Saed , Faisal Alsheddi , Ahlam H. Alamri , Atef M. Shibl , Khalid H. Alanazi
{"title":"Infection control Surveillance of dialysis events at outpatient hemodialysis centers in Saudi Arabia: A 3-year national data","authors":"Mohammed ALQahtani ,&nbsp;Aiman El-Saed ,&nbsp;Faisal Alsheddi ,&nbsp;Ahlam H. Alamri ,&nbsp;Atef M. Shibl ,&nbsp;Khalid H. Alanazi","doi":"10.1016/j.infpip.2025.100447","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Monitoring dialysis events is very important in evaluating the risk of infection and antimicrobial use among this group of vulnerable patients. The objective was to calculate rates of dialysis events at outpatient hemodialysis centers in Saudi Arabia.</div></div><div><h3>Methods</h3><div>A retrospective cohort study of dialysis events collected from 152 outpatient hemodialysis centers in 20 Saudi regions between January 2019 and December 2021. The Saudi Health Electronic System Network (HESN) was used to report data from participating centers. Dialysis events included in-unit intravenous antimicrobial start, positive blood culture, and infection (pus, redness, and swelling) at the vascular access site.</div></div><div><h3>Results</h3><div>A total of 125,761 patient months of surveillance were monitored. The most frequent type of dialysis event was the in-unit intravenous antimicrobial start at 0.75 per 100 patient months, followed by positive blood culture at 0.41, and finally, local access of the infection site at 0.34. The rates of dialysis events were highest, with temporary central lines at 4.36, permanent central lines at 1.87, arteriovenous graft at 0.35, and finally, arteriovenous fistula at 0.17. After adjusting for the differences in the type of vascular access, the rates of dialysis events in the Saudi HESN were lower, 54%–83%, than those of the American National Healthcare Safety Network (NHSN, <em>P</em>&lt;0.001 for each) and a less extent 27%–55% lower when compared with the published results from Chinese people.</div></div><div><h3>Conclusions</h3><div>The current findings provide benchmarking data for different dialysis events that can promote fair comparisons and interest in dialysis event surveillance.</div></div>","PeriodicalId":33492,"journal":{"name":"Infection Prevention in Practice","volume":"7 1","pages":"Article 100447"},"PeriodicalIF":1.8000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infection Prevention in Practice","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590088925000113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Monitoring dialysis events is very important in evaluating the risk of infection and antimicrobial use among this group of vulnerable patients. The objective was to calculate rates of dialysis events at outpatient hemodialysis centers in Saudi Arabia.

Methods

A retrospective cohort study of dialysis events collected from 152 outpatient hemodialysis centers in 20 Saudi regions between January 2019 and December 2021. The Saudi Health Electronic System Network (HESN) was used to report data from participating centers. Dialysis events included in-unit intravenous antimicrobial start, positive blood culture, and infection (pus, redness, and swelling) at the vascular access site.

Results

A total of 125,761 patient months of surveillance were monitored. The most frequent type of dialysis event was the in-unit intravenous antimicrobial start at 0.75 per 100 patient months, followed by positive blood culture at 0.41, and finally, local access of the infection site at 0.34. The rates of dialysis events were highest, with temporary central lines at 4.36, permanent central lines at 1.87, arteriovenous graft at 0.35, and finally, arteriovenous fistula at 0.17. After adjusting for the differences in the type of vascular access, the rates of dialysis events in the Saudi HESN were lower, 54%–83%, than those of the American National Healthcare Safety Network (NHSN, P<0.001 for each) and a less extent 27%–55% lower when compared with the published results from Chinese people.

Conclusions

The current findings provide benchmarking data for different dialysis events that can promote fair comparisons and interest in dialysis event surveillance.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Infection Prevention in Practice
Infection Prevention in Practice Medicine-Public Health, Environmental and Occupational Health
CiteScore
4.80
自引率
0.00%
发文量
58
审稿时长
61 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信