Refinement of Protein Extraction Protocols for Human Peripheral Nerve Tissue

IF 3.7 3区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
Drifa Frostadottir*, Charlotte Welinder, Raquel Perez and Lars B. Dahlin, 
{"title":"Refinement of Protein Extraction Protocols for Human Peripheral Nerve Tissue","authors":"Drifa Frostadottir*,&nbsp;Charlotte Welinder,&nbsp;Raquel Perez and Lars B. Dahlin,&nbsp;","doi":"10.1021/acsomega.4c1137310.1021/acsomega.4c11373","DOIUrl":null,"url":null,"abstract":"<p >Our aim was to establish an effective method for protein extraction from freshly frozen human peripheral nerves, determine the minimum amount required for consistent protein extraction outcomes, and assess which method produced the highest number of protein identities. Five extraction methods were compared using 8 M urea and Ripa buffer using either the Bullet Blender or Bioruptor. Out of the total 2619 identified proteins, protein extraction using the Ripa buffer combined with either Bioruptor or Bullet Blender resulted in the identification of 1582 (60%) and 1615 (62%) proteins, respectively. In contrast, using 8 M urea and Bioruptor for protein extraction resulted in 1022 proteins (39%), whereas employing Bullet Blender yielded 1446 proteins (55%). Sample amounts, ranging from 0.6 to 10 mg, were prepared with consistent protein extraction outcome obtained for samples ≥1.2 mg. Combining Ripa and 8 M urea with Bullet Blender increased protein identification to 2126 (81%). Proteins were classified by their cell components, molecular functions, and biological processes. Furthermore, a subclassification of proteins involved in the extracellular matrix (ECM) was introduced. We recommend the use of Ripa buffer, in combination with 8 M urea and Bullet Blender for extracting proteins from fresh-frozen human nerves weighing ≥1.2 mg.</p>","PeriodicalId":22,"journal":{"name":"ACS Omega","volume":"10 5","pages":"5111–5118 5111–5118"},"PeriodicalIF":3.7000,"publicationDate":"2025-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acsomega.4c11373","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Omega","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsomega.4c11373","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Our aim was to establish an effective method for protein extraction from freshly frozen human peripheral nerves, determine the minimum amount required for consistent protein extraction outcomes, and assess which method produced the highest number of protein identities. Five extraction methods were compared using 8 M urea and Ripa buffer using either the Bullet Blender or Bioruptor. Out of the total 2619 identified proteins, protein extraction using the Ripa buffer combined with either Bioruptor or Bullet Blender resulted in the identification of 1582 (60%) and 1615 (62%) proteins, respectively. In contrast, using 8 M urea and Bioruptor for protein extraction resulted in 1022 proteins (39%), whereas employing Bullet Blender yielded 1446 proteins (55%). Sample amounts, ranging from 0.6 to 10 mg, were prepared with consistent protein extraction outcome obtained for samples ≥1.2 mg. Combining Ripa and 8 M urea with Bullet Blender increased protein identification to 2126 (81%). Proteins were classified by their cell components, molecular functions, and biological processes. Furthermore, a subclassification of proteins involved in the extracellular matrix (ECM) was introduced. We recommend the use of Ripa buffer, in combination with 8 M urea and Bullet Blender for extracting proteins from fresh-frozen human nerves weighing ≥1.2 mg.

求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Omega
ACS Omega Chemical Engineering-General Chemical Engineering
CiteScore
6.60
自引率
4.90%
发文量
3945
审稿时长
2.4 months
期刊介绍: ACS Omega is an open-access global publication for scientific articles that describe new findings in chemistry and interfacing areas of science, without any perceived evaluation of immediate impact.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信