A point-of-care, label-free OECT sensor for uric acid detection: validation in human saliva

IF 5.5 3区 材料科学 Q1 ELECTROCHEMISTRY
Francesca Ceccardi, Federica Mariani, Francesco Decataldo, Vito Vurro, Marta Tessarolo, Isacco Gualandi, Beatrice Fraboni, Erika Scavetta
{"title":"A point-of-care, label-free OECT sensor for uric acid detection: validation in human saliva","authors":"Francesca Ceccardi, Federica Mariani, Francesco Decataldo, Vito Vurro, Marta Tessarolo, Isacco Gualandi, Beatrice Fraboni, Erika Scavetta","doi":"10.1016/j.electacta.2025.145834","DOIUrl":null,"url":null,"abstract":"This study presents the development of an organic electrochemical transistor (OECT) sensor for the detection of uric acid (UA) in human saliva, employing a potentiodynamic measurement technique. Unlike many existing (bio)sensors, this device is entirely based on the organic semiconductor poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), which simplifies manufacturing and maintenance and reduces production costs. First of all, a systematic comparison between the potentiostatic and potentiodynamic sensing performance in buffer solution is presented, which proves the superior accuracy (14%), repeatability (5%), and reproducibility (8%) of the potentiodynamic approach. In particular, a sensitivity of 59 µS dec<sup>−1</sup> is obtained in the concentration range 10 – 350 µM UA, with a detection limit of 1 µM. Selectivity studies and subsequent validation of the potentiodynamic OECT sensor in human saliva with an independent method specific for salivary UA quantification is then presented, after which we show the application of our sensor to salivary UA monitoring during food intake, as well as the attempt to analyze swine saliva. Furthermore, as the sensor's design supports integration with point-of-care platforms, we demonstrate its functionality with portable electronics and smartphone connectivity. This approach enables rapid, real-time monitoring, offering a practical and cost-effective solution for non-invasive UA detection in clinical settings.","PeriodicalId":305,"journal":{"name":"Electrochimica Acta","volume":"50 1","pages":""},"PeriodicalIF":5.5000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrochimica Acta","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1016/j.electacta.2025.145834","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents the development of an organic electrochemical transistor (OECT) sensor for the detection of uric acid (UA) in human saliva, employing a potentiodynamic measurement technique. Unlike many existing (bio)sensors, this device is entirely based on the organic semiconductor poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), which simplifies manufacturing and maintenance and reduces production costs. First of all, a systematic comparison between the potentiostatic and potentiodynamic sensing performance in buffer solution is presented, which proves the superior accuracy (14%), repeatability (5%), and reproducibility (8%) of the potentiodynamic approach. In particular, a sensitivity of 59 µS dec−1 is obtained in the concentration range 10 – 350 µM UA, with a detection limit of 1 µM. Selectivity studies and subsequent validation of the potentiodynamic OECT sensor in human saliva with an independent method specific for salivary UA quantification is then presented, after which we show the application of our sensor to salivary UA monitoring during food intake, as well as the attempt to analyze swine saliva. Furthermore, as the sensor's design supports integration with point-of-care platforms, we demonstrate its functionality with portable electronics and smartphone connectivity. This approach enables rapid, real-time monitoring, offering a practical and cost-effective solution for non-invasive UA detection in clinical settings.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Electrochimica Acta
Electrochimica Acta 工程技术-电化学
CiteScore
11.30
自引率
6.10%
发文量
1634
审稿时长
41 days
期刊介绍: Electrochimica Acta is an international journal. It is intended for the publication of both original work and reviews in the field of electrochemistry. Electrochemistry should be interpreted to mean any of the research fields covered by the Divisions of the International Society of Electrochemistry listed below, as well as emerging scientific domains covered by ISE New Topics Committee.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信