Comparison of Patent Foramen Ovale Sizing by Transesophageal Echocardiography and Balloon Sizing in Patients Undergoing Percutaneous Closure

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Birgitte Carbuhn Larsen MD , Martin Christian Harmsen MD , Henrik Vase MD, PhD , Jens Erik Nielsen-Kudsk MD, DMSc , Asger Andersen MD, PhD
{"title":"Comparison of Patent Foramen Ovale Sizing by Transesophageal Echocardiography and Balloon Sizing in Patients Undergoing Percutaneous Closure","authors":"Birgitte Carbuhn Larsen MD ,&nbsp;Martin Christian Harmsen MD ,&nbsp;Henrik Vase MD, PhD ,&nbsp;Jens Erik Nielsen-Kudsk MD, DMSc ,&nbsp;Asger Andersen MD, PhD","doi":"10.1016/j.shj.2024.100375","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>A patent foramen ovale (PFO) has a complex anatomy, and evaluating the size before closure may be challenging. We aimed to investigate the correlation between preprocedural transesophageal echocardiography (TEE) and balloon sizing of PFO in patients undergoing percutaneous PFO closure.</div></div><div><h3>Methods</h3><div>A retrospective single-center study with analysis of 100 patients who, due to paradox thromboembolism in the left circulation, underwent percutaneous PFO closure. The PFO sizing was compared to measures attained by TEE and balloon sizing using linear regression analysis.</div></div><div><h3>Results</h3><div>PFO size measured by TEE occurred smaller than balloon sizing (2.19 mm [95% CI: 1.91 to 2.46] vs. 8.51 mm [95% CI: 8.02 to 9.00], <em>p</em> &lt; 0.001). Additionally, neither the PFO channel length nor the atrial septal mobility measured by TEE correlated to the PFO size attained by balloon sizing, respectively (slope <strong>−</strong>0.018 [95% CI: <strong>−</strong>0.117 to 0.081], R = 0.036, <em>p</em> = 0.719) and (slope 0.049 [95% CI: ?0.043 to 0.141], R = 0.105, <em>p</em> = 0.297). Statistically significant difference in regression analysis but poor correlation was found between both TEE attained PFO and shunt size when compared to balloon sizing. Diverting patients according to the size of the PFO shunt was not statistically significant between PFO of moderate size compared, respectively, to a large and small PFO size. However, a difference was observed between a small and large PFO shunt size.</div></div><div><h3>Conclusions</h3><div>PFO defect and shunt size measured by TEE showed a poor correlation with balloon sizing. Neither PFO channel length nor septal mobility were correlated to the PFO size measured by balloon sizing.</div></div>","PeriodicalId":36053,"journal":{"name":"Structural Heart","volume":"9 1","pages":"Article 100375"},"PeriodicalIF":1.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Heart","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2474870624001362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

A patent foramen ovale (PFO) has a complex anatomy, and evaluating the size before closure may be challenging. We aimed to investigate the correlation between preprocedural transesophageal echocardiography (TEE) and balloon sizing of PFO in patients undergoing percutaneous PFO closure.

Methods

A retrospective single-center study with analysis of 100 patients who, due to paradox thromboembolism in the left circulation, underwent percutaneous PFO closure. The PFO sizing was compared to measures attained by TEE and balloon sizing using linear regression analysis.

Results

PFO size measured by TEE occurred smaller than balloon sizing (2.19 mm [95% CI: 1.91 to 2.46] vs. 8.51 mm [95% CI: 8.02 to 9.00], p < 0.001). Additionally, neither the PFO channel length nor the atrial septal mobility measured by TEE correlated to the PFO size attained by balloon sizing, respectively (slope 0.018 [95% CI: 0.117 to 0.081], R = 0.036, p = 0.719) and (slope 0.049 [95% CI: ?0.043 to 0.141], R = 0.105, p = 0.297). Statistically significant difference in regression analysis but poor correlation was found between both TEE attained PFO and shunt size when compared to balloon sizing. Diverting patients according to the size of the PFO shunt was not statistically significant between PFO of moderate size compared, respectively, to a large and small PFO size. However, a difference was observed between a small and large PFO shunt size.

Conclusions

PFO defect and shunt size measured by TEE showed a poor correlation with balloon sizing. Neither PFO channel length nor septal mobility were correlated to the PFO size measured by balloon sizing.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Structural Heart
Structural Heart Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.60
自引率
0.00%
发文量
81
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信