{"title":"Erratum to ‘Cost differences between autologous and nonautologous cranioplasty implants: A propensity score–matched value driven outcomes analysis’ [World Neurosurgery: X (22C) (2024) (100358)]","authors":"Matthew Findlay ,&nbsp;Sawyer Z. Bauer ,&nbsp;Diwas Gautam ,&nbsp;Matthew Holdaway ,&nbsp;Robert B. Kim ,&nbsp;Walid K. Salah ,&nbsp;Spencer Twitchell ,&nbsp;Sarah T. Menacho ,&nbsp;Gurpreet S. Gandhoke ,&nbsp;Ramesh Grandhi","doi":"10.1016/j.wnsx.2024.100424","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>Despite having higher rates of failure and revision than other implant materials, autologous bone implants are the historical gold standard for restoring cranial defects after decompressive hemicraniectomy. More reliable synthetic implants have been developed, but they are significantly more expensive than autologous bone. The authors sought to compare the initial and long-term costs of custom synthetic implants and autologous cranioplasty grafts.</div></div><div><h3>Methods</h3><div>The authors reviewed the hospital billing records over a 12-year period at their institution to identify patients who underwent cranioplasty after decompressive hemicraniectomy for trauma or stroke. The costs for imaging, hospital supplies, implants, pharmacy services, facility usage, and laboratory studies were captured for initial surgeries and for subsequent cranioplasty-related revision hospitalizations and surgeries. Clinical characteristics, long-term outcomes, and cost differences of autologous versus custom implants were compared by using univariate and multivariate analyses. These analyses were repeated after propensity-score matching adjusted for factors predictive of cranioplasty failure.</div></div><div><h3>Results</h3><div>On unmatched analysis, 32 custom and 128 autologous implants were analyzed. Differences in initial cranioplasty failure rates between custom and autologous grafts were insignificant (12.5 % custom vs. 23.4 % autologous, p = 0.18). On univariate analysis, autologous implants cost 46.8 % of custom grafts during the initial hospitalization period (p &lt; 0.01) and 58.7 % of custom grafts once long-term aggregated costs were factored (p &lt; 0.01). Upon multivariate analysis, although custom cranioplasty was independently predictive of higher initial hospitalization costs (standardized β = 0.20, p &lt; 0.01), it was not predictive of long-term total aggregated costs (standardized β = 0.10, p = 0.13). After propensity score matching (29 custom, 29 autologous cases), multivariate analysis of the matched cohorts likewise found custom implants were predictive of greater initial hospitalization costs (standardized β = 0.56, p &lt; 0.01), but were not an independent driver of aggregated long-term costs (standardized β = 0.22, p = 0.11).</div></div><div><h3>Conclusion</h3><div>Our matched and unmatched multivariate analysis found nonsignificant cost differences between custom and autologous cranioplasties once initial and long-term costs were aggregated, suggesting custom implants could be considered as a primary therapeutic intervention.</div></div>","PeriodicalId":37134,"journal":{"name":"World Neurosurgery: X","volume":"25 ","pages":"Article 100424"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Neurosurgery: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590139724001558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

Despite having higher rates of failure and revision than other implant materials, autologous bone implants are the historical gold standard for restoring cranial defects after decompressive hemicraniectomy. More reliable synthetic implants have been developed, but they are significantly more expensive than autologous bone. The authors sought to compare the initial and long-term costs of custom synthetic implants and autologous cranioplasty grafts.

Methods

The authors reviewed the hospital billing records over a 12-year period at their institution to identify patients who underwent cranioplasty after decompressive hemicraniectomy for trauma or stroke. The costs for imaging, hospital supplies, implants, pharmacy services, facility usage, and laboratory studies were captured for initial surgeries and for subsequent cranioplasty-related revision hospitalizations and surgeries. Clinical characteristics, long-term outcomes, and cost differences of autologous versus custom implants were compared by using univariate and multivariate analyses. These analyses were repeated after propensity-score matching adjusted for factors predictive of cranioplasty failure.

Results

On unmatched analysis, 32 custom and 128 autologous implants were analyzed. Differences in initial cranioplasty failure rates between custom and autologous grafts were insignificant (12.5 % custom vs. 23.4 % autologous, p = 0.18). On univariate analysis, autologous implants cost 46.8 % of custom grafts during the initial hospitalization period (p < 0.01) and 58.7 % of custom grafts once long-term aggregated costs were factored (p < 0.01). Upon multivariate analysis, although custom cranioplasty was independently predictive of higher initial hospitalization costs (standardized β = 0.20, p < 0.01), it was not predictive of long-term total aggregated costs (standardized β = 0.10, p = 0.13). After propensity score matching (29 custom, 29 autologous cases), multivariate analysis of the matched cohorts likewise found custom implants were predictive of greater initial hospitalization costs (standardized β = 0.56, p < 0.01), but were not an independent driver of aggregated long-term costs (standardized β = 0.22, p = 0.11).

Conclusion

Our matched and unmatched multivariate analysis found nonsignificant cost differences between custom and autologous cranioplasties once initial and long-term costs were aggregated, suggesting custom implants could be considered as a primary therapeutic intervention.
求助全文
约1分钟内获得全文 求助全文
来源期刊
World Neurosurgery: X
World Neurosurgery: X Medicine-Surgery
CiteScore
3.10
自引率
0.00%
发文量
23
审稿时长
44 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信