Efficacy of an artificial intelligence preoperative planning system for assisting in revision surgery after artificial total hip arthroplasty.

IF 1.6 3区 医学 Q2 SURGERY
Jiaqing Zhu, Shanbin Zheng, Jiahao Sun, Bowen Ma, Chiyu Zhang, Chao Zhang, Jirong Shen, Tianwei Xia
{"title":"Efficacy of an artificial intelligence preoperative planning system for assisting in revision surgery after artificial total hip arthroplasty.","authors":"Jiaqing Zhu, Shanbin Zheng, Jiahao Sun, Bowen Ma, Chiyu Zhang, Chao Zhang, Jirong Shen, Tianwei Xia","doi":"10.1186/s12893-024-02752-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To explore the early efficacy of an artificial intelligence preoperative planning system (AIHIP system) for assisting in hip revision surgery.</p><p><strong>Methods: </strong>The clinical data of 25 patients (26 hips) who underwent hip revision between June 2019 and December 2023 and who met the selection criteria were retrospectively analyzed. There were 13 males and 12 females; the ages ranged from 44 to 90 years, with a mean of 69.1 years. The patients' replacement of prosthesis model, operation time, hospitalization time, postoperative time out of bed, etc., as well as the occurrence of adverse events such as postoperative infection, fracture, and loosening of the prosthesis were recorded. The Harris Hip score (HHS) was used to evaluate the function of the affected limbs preoperatively, and 1 week and 6 months postoperatively, and hip mobility was compared preoperatively and 6 months postoperatively.</p><p><strong>Results: </strong>All 25 patients were followed up for 6 to 59 months, with an average of 25.3 months. Except for one patient who developed a thigh hematoma (treated with incision and drainage and decompression) and hip dislocation in one hip (repaired), the remaining patients experienced no adverse events such as loosening of the prosthesis or infection. The postoperative acetabular cup type matching degree completely matched 25 hips, not matching 1 hip (+ 2 number), for a matching rate of 96.15%; the femoral stem type matching degree completely matched 25 hips, generally matching 1 hip (-1 number), for a matching rate of 100%. The Harris scores were 54.7 ± 9.6 and 89.6 ± 7.0 at 1 week and 6 months after surgery, respectively, which were significantly improved (P < 0.05) compared with the preoperative scores of 33.5 ± 8.3, and further improved at 6 months after surgery compared with the 1-week period (P < 0.05). The patients' hip function was evaluated according to the Harris score at 6 months after surgery, and they were assigned to 23 good hips and 3 medium hips, which could satisfy daily life needs. Hip mobility at 6 months after surgery was 111.15 ± 9.72°, and the difference was statistically significant compared with the preoperative value of 79.42 ± 17.51° (t = -8.077, P < 0.001).</p><p><strong>Conclusion: </strong>AIHIP system-assisted treatment of THA postoperative revision patients can improve the precision of revision surgery, and reduce the difficulty of surgery, in patients with good postoperative recovery and satisfactory early outcomes.</p>","PeriodicalId":49229,"journal":{"name":"BMC Surgery","volume":"25 1","pages":"58"},"PeriodicalIF":1.6000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12893-024-02752-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To explore the early efficacy of an artificial intelligence preoperative planning system (AIHIP system) for assisting in hip revision surgery.

Methods: The clinical data of 25 patients (26 hips) who underwent hip revision between June 2019 and December 2023 and who met the selection criteria were retrospectively analyzed. There were 13 males and 12 females; the ages ranged from 44 to 90 years, with a mean of 69.1 years. The patients' replacement of prosthesis model, operation time, hospitalization time, postoperative time out of bed, etc., as well as the occurrence of adverse events such as postoperative infection, fracture, and loosening of the prosthesis were recorded. The Harris Hip score (HHS) was used to evaluate the function of the affected limbs preoperatively, and 1 week and 6 months postoperatively, and hip mobility was compared preoperatively and 6 months postoperatively.

Results: All 25 patients were followed up for 6 to 59 months, with an average of 25.3 months. Except for one patient who developed a thigh hematoma (treated with incision and drainage and decompression) and hip dislocation in one hip (repaired), the remaining patients experienced no adverse events such as loosening of the prosthesis or infection. The postoperative acetabular cup type matching degree completely matched 25 hips, not matching 1 hip (+ 2 number), for a matching rate of 96.15%; the femoral stem type matching degree completely matched 25 hips, generally matching 1 hip (-1 number), for a matching rate of 100%. The Harris scores were 54.7 ± 9.6 and 89.6 ± 7.0 at 1 week and 6 months after surgery, respectively, which were significantly improved (P < 0.05) compared with the preoperative scores of 33.5 ± 8.3, and further improved at 6 months after surgery compared with the 1-week period (P < 0.05). The patients' hip function was evaluated according to the Harris score at 6 months after surgery, and they were assigned to 23 good hips and 3 medium hips, which could satisfy daily life needs. Hip mobility at 6 months after surgery was 111.15 ± 9.72°, and the difference was statistically significant compared with the preoperative value of 79.42 ± 17.51° (t = -8.077, P < 0.001).

Conclusion: AIHIP system-assisted treatment of THA postoperative revision patients can improve the precision of revision surgery, and reduce the difficulty of surgery, in patients with good postoperative recovery and satisfactory early outcomes.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Surgery
BMC Surgery SURGERY-
CiteScore
2.90
自引率
5.30%
发文量
391
审稿时长
58 days
期刊介绍: BMC Surgery is an open access, peer-reviewed journal that considers articles on surgical research, training, and practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信