Accuracy of Intraoral Scanning Versus Analog Impression for Multiple Implant-supported Prostheses in Long Edentulous Spans: A Comparative Clinical Study.

Jie Ma, Binghua Zhang, Hao Song, Shuang Xu, Tiantian Chen, Tao Song
{"title":"Accuracy of Intraoral Scanning Versus Analog Impression for Multiple Implant-supported Prostheses in Long Edentulous Spans: A Comparative Clinical Study.","authors":"Jie Ma, Binghua Zhang, Hao Song, Shuang Xu, Tiantian Chen, Tao Song","doi":"10.11607/ijp.9180","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Clinical scientific evidence of the accuracy of intraoral scanning (IOS) impressions for multiple implant-supported prostheses in partially edentulous arches is limited. This in vivo study aimed to evaluate the accuracy of IOS impressions for multiple implants by comparing them with analog impressions.</p><p><strong>Materials and methods: </strong>Patients with three adjacent implants in partially edentulous arches were recruited. For each arch, IOS impressions were obtained. Using the analog splinted impression technique, casts were obtained and scanned with an extraoral scanner. Using metrology software, the distances and angles between the implants were measured in all IOS and analog impression Standard Tessellation Language files. The absolute values of the distance and angular deviation were calculated and analyzed by comparing the two impression methods.</p><p><strong>Results: </strong>Thirty-four patients with partially edentulous arches were enrolled. The distance deviation between the IOS and analog impressions was 85.09 ± 58.73 µm, which was significantly lower than the clinically acceptable error (150 µm; P < .001). The angular deviation was 0.515 ± 0.426°. Distance deviations were significantly correlated with the interimplant distances (r = 0.384, P = .001) and angulations (r = 0.278, P =.022).</p><p><strong>Conclusions: </strong>For multiple implant-supported prostheses in partially edentulous arches, the distance deviation between the IOS and analog impression was within the clinicall acceptable range of misfit and increased with increasing interimplant distance and angulation.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-17"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Clinical scientific evidence of the accuracy of intraoral scanning (IOS) impressions for multiple implant-supported prostheses in partially edentulous arches is limited. This in vivo study aimed to evaluate the accuracy of IOS impressions for multiple implants by comparing them with analog impressions.

Materials and methods: Patients with three adjacent implants in partially edentulous arches were recruited. For each arch, IOS impressions were obtained. Using the analog splinted impression technique, casts were obtained and scanned with an extraoral scanner. Using metrology software, the distances and angles between the implants were measured in all IOS and analog impression Standard Tessellation Language files. The absolute values of the distance and angular deviation were calculated and analyzed by comparing the two impression methods.

Results: Thirty-four patients with partially edentulous arches were enrolled. The distance deviation between the IOS and analog impressions was 85.09 ± 58.73 µm, which was significantly lower than the clinically acceptable error (150 µm; P < .001). The angular deviation was 0.515 ± 0.426°. Distance deviations were significantly correlated with the interimplant distances (r = 0.384, P = .001) and angulations (r = 0.278, P =.022).

Conclusions: For multiple implant-supported prostheses in partially edentulous arches, the distance deviation between the IOS and analog impression was within the clinicall acceptable range of misfit and increased with increasing interimplant distance and angulation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信